F-60 Questions with correct Answers 2023
F-60 Questions with correct Answers 2023 Fire guard A person holding a certificate of fitness for such purposes , whois trained in and responsible for maintaining a fire watch and performed fire safety duties as may be prescribed by the commisioner fire watch A temporary measure intended to ensure continuous and systematic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, detecting early signs of fire, raising an alarm of fire and notifying the department. hot work Cutting, welding, thermit welding, brazing, soldering, grinding, thermal spraying, thawing pipe, cad welding, installation of torch-applied system, or any other similar operation or activity. Hot Work Area The area exposed to sparks, hot slag, radiant heat, or convective heat as a result of hot work hot work equipments electric or gas welding or cutting equipment used for hot work hot work program program,implemented by a responsible person designated by the owner of a building or structure in or on which hot work is being performed,to oversee and issue authorizations for such hot work for the purpose of preventing fire and fire spread hot work program authorization authorization issued by the responsible person under a hot work program allowing welding or other hot work to be performed at the presmises NFPA National Fire Protection Association. The worlds leading advocate for fire protection and an authoritative source on public safety . NFPA develops, publishes, and disseminates more than 300 consensus codes and standards intended to minimize the possibility and effects of fire and other risks responsible person person trained in the fire safety hazards associated with hot work and in the necessary and appropriate measures to minimize those hazards who is designated by the owner of a premises to authorize the performance of hot work at the premises Torch Applied Roof-System Bituminous roofing systems using membranes that are adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion. A high temperature flame is need to perform______ hot work operation What causes fire? thousands of sparks and pieces of hot metal generated when using a torch possible sources of ignition and to what percentage are these the possible source in all fires sparks and pieces of hot metal 60% of all fires Rules to prevent fire safe distance between combustible materials, the hot work operation area, a fire guard watching for sparks have fire safety have licensed renovation how to get hot work operation with citywide permit the owner of the premises of the hot work operation area must be notified in writing by the city wide permit holder atleast 48 hours before the hot work is started who is the owner of the hot work operation area designated responsible person what does the responsible person do must ensure that the hot work is performed in compliance with the terms and conditions on the permit inspect the hot work site prior to issuing the hot work authorization to ensure it is a fire safe area periodically monitor the work as it is performed to ensure there are no safety hazards hot work operation must be conducted under the general supervision of___ the responsible person before hot work is authorized and should be done once a day ___ the hot work area should be inspected by the responsible person to ensure that it is a fire safe area what must be conducted by the responsible person before hotnwork is authorized and atleast once per day pre-hot check check reports must be kept at work site during the work and made available for inspection by a representative of the FDNY and maintained on the premises for a minimum of 48 hours after the work is completed a pre hot work check must verify ____ the hot work equipment is in good working order the hot work area is clear of combustible and flammable solids exposed construction is of noncombustible or if combustible its protected openings are protected hot work area floors are clear of combustible waste accumulation fire watch personnel, where require, are assigned approved actions have been taken to prevent accidental activation of fire extinguishing systems detection equipment portable fire extinguishers and fire hoses are operable and available all persons performing hot work posseses certificates of fitness where require all persons Performing Hardwork requiring a permit possesses a site specific permit or citywide permit authorizing such work 35 feet rule for cutting or welding operation Hardwork operations involving cutting or welding shall be conducted at least 35 feet from combustible materials and combustible Waze or shall be provided with appropriate shielding to prevent sparks, slag or heat from igniting expose combustibles 25 feet rule for other hot operation All other hot work operation shall be conducted at least 25 feet from combustible materials and combustible ways we shall be provided with appropriate shielding to prevent sparks slag reheat for igniting exposed combustibles sprinkles protection Sprinkler system protection must not be shut off or impaired for hot work is performed we're hot work is perform close to sprinklers non-combustible barriers or damp clothes guards shall shield the individual sprinkler heads and shall be removed when the work is completed if the word extends over several days the shell shall be removed at the end of each workday Fire Detection System Approved precautionary measures shall be taken to avoid accidental operation out of automatic fire detection systems G-60 required for torch operation Using oxygen and flammable gas G-60 or G-42 or G-42 Required for torch applied with system F 60 Required to perform the firewatch for torch operations at construction sites on any rooftop or in any building or structure when the torch operation is conducted by person holding a citywide permit for torch operation gas torch operation precautions each person is operate only one torch at a time and such torch must not be left unattended while ignited The torch equipment should only be used for purposes for which it was intended protection of combustibles areas designated for hot work operation shall have floors with non-combustible surfaces paper, wood shavings, straw and fabric or examples of combustible materials special requirements for a repair garage The use of a torch within a repair garage located on the property upon which a motor fuel dispensing facility is situated must be conducted within a fire rated and closure all doors of such enclosure shall be fireproof and self signage Where the hot work area is assessable to persons other than the operator of the hot work equipment visible hazards identification signs must be posted in a conspicuous location to warn others before they enter the hot area fire watch must be maintained during any hot work operation and shall observe the entire hot work area At work areas with vertical or horizontal fire exposures that are not observable by single individual should have an additional personnel assigned to ensure the exposed areas are monitored
Written for
- Institution
- FDNY G60
- Course
- FDNY G60
Document information
- Uploaded on
- August 3, 2023
- Number of pages
- 6
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- hot work cutting
- welding
- thermit welding
- brazin
- hot wor
-
f 60 questions with correct answers 2023
-
fire guard a person holding a certificate of fitne
-
fire watch a temporary measure intended to ensure
Also available in package deal