100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
OIL BURNER LICENSE EXAM QUESTIONS AND ANSWERS #11 CA$19.84   Add to cart

Exam (elaborations)

OIL BURNER LICENSE EXAM QUESTIONS AND ANSWERS #11

 5 views  0 purchase

OIL BURNER LICENSE EXAM QUESTIONS AND ANSWERS #11

Preview 3 out of 18  pages

  • July 9, 2024
  • 18
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
All documents for this subject (105)
avatar-seller
puritywanjihia
OIL BURNER LICENSE EXAM QUESTIONS AND ANSWERS #11

What is the first thing a tech should do when arriving at a no combustion call? - correct
answer Ask how many times the customer reset the unit.

What is the best long term solution for preventing a clogged nozzle? - correct answer -
Remove any underground storage tanks.
-Install a quality oil filter.
-Cut the suction line 10" above the tank outlet to prevent sludge.

Hot water and steam valves are interchangeable. - correct answer False

When in the presence of a flame, a cad cell normally reads.. - correct answer 300-1000
ohms

If a pump is used to bring oil to a level higher than the tank, an oil safety valve is
required. - correct answer True

On a call where a hydronic heat system is putting out too much heat on the stack, the
issue may be.. - correct answer -Too much draft.
-Not enough combustion air in the equipment room.
-Air leakage into chamber.

A high CO2 reading is caused by.. - correct answer Incomplete combustion

An often overlooked cause of a high CO2 reading is.. - correct answer Not enough
combustion air in the equipment room.

When multiple pumps are wired together in a heating system, they should be wired in.. -
correct answer parallel

In a series circuit.. - correct answer Current has one path.

When 2 burners are connected to the same chimney.. - correct answer Sufficient draft
must be obtained to operate both units.

The ignition transformer is located.. - correct answer In the primary control.

When safeties are wired in series one safety will affect the operation of the others. -
correct answer True

,A stack switch is no longer allowed to be installed or replaced because.. - correct
answer It's safety cutout time is higher than what is now required.

What is a power venter and what does it do? - correct answer An electrical device that
sends fluid gases into the chimney connector.

A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent
opening for combustion air? - correct answer 140"

The difference between an adjustable flame retention burner and a fixed flame retention
burner is? - correct answer Air inlets can be adjusted

Ignitor position can be adjusted

Fuel can be adjusted

Oil tank design, construction, installation and testing shall be in accordance with.. -
correct answer 527 CMR 9.0

Heat is a form of.. - correct answer Energy

If a burner is operational but the circulator pump isn't running.. - correct answer The
pump relay is not working correctly

A method of dealing with low viscosity/cold temps with #2 oil? - correct answer Increase
pump pressure/ decrease nozzle size

What is needed at the outlet of an oil tank? - correct answer Thermal safety valve

Where do you obtain an installation permit for oil burners? - correct answer Fire Dept

How many Btu's approximately in 1 gal of #2 fuel oil? - correct answer 140,000 btu's

Solid state ignition is superior to spark because - correct answer It is not affected by
reduced voltage

What is an installation? - correct answer The complete setting in place, ready for
operation, of an oil burner appliance together with its accessories and equipment.

How far must a power vent terminate from an opening or window? - correct answer 4'

A pump in a one pipe system that is full of air can be self purged. - correct answer False

List the minimum size of an oil supply line. - correct answer 3/8"

, A material with electrons so loose it allows voltage to pass with little or no resistance.. -
correct answer Is a conductor

If a high limit goes off, what does a low water switch do? - correct answer Maintains
water temperature

What is flashpoint an indicator of? - correct answer Minimum temperature oil will ignite
but not continue to burn.

What travels on the inside of the wire? - correct answer Volts

What does readily accessible mean pertaining to oil burning equipment? - correct
answer Capable of being reached easily and quickly for operation, maintenance or
inspection.

What is the minimum vent pipe on an oil tank? - correct answer 1 1/4"

What causes corrosion on a flue pipe? - correct answer When the flue pipe is operating
below the dew point temperature.

What are the methods to prevent oil waxing? - correct answer Put additives in the fuel.

Add an oil line heater.

Cut with #1 fuel or kerosene.

What is the maximum tank size allowed inside unenclosed? - correct answer 660 gal

What is the purpose of a delayed oil valve? - correct answer Allows time for the oil
pump to get up to speed.

Delays oil flow to the nozzle.

On a call where a hydronic heat system is putting out too much heat, the issue could
be? - correct answer A shorted out thermostat.

When measuring a cad cell with the burner running and the ff terminals jumped out,
what should the cad cell reading be? - correct answer 1600 ohms

What are the possible causes of soot at or near the power venter? - correct answer
Incomplete combustion

What is a possible side effect of air in a nozzle line? - correct answer Soot

What is the cause if the cad cell is tripped on safety? - correct answer Dirty cad cell

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller puritywanjihia. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for CA$19.84. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76800 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
CA$19.84
  • (0)
  Add to cart