100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
MASSACHUSETTS PLUMBERS JOURNEYMAN: EXAM QUESTIONS & ANSWERS VERIFIED 100% CORRECT 2024,2025 CA$11.49   Add to cart

Exam (elaborations)

MASSACHUSETTS PLUMBERS JOURNEYMAN: EXAM QUESTIONS & ANSWERS VERIFIED 100% CORRECT 2024,2025

 11 views  0 purchase
  • Course
  • MASSACHUSETTS PLUMBERS JOURNEYMAN
  • Institution
  • MASSACHUSETTS PLUMBERS JOURNEYMAN

A combination waste-and-vent system is limited to the installation of - floor drains and sinks A permit from the _________ & ________ shall be obtained for the installation of an unvented gas fired space room heater. - Fire Dept. & Gas Inspector 1. Any structure, in which a building drain is ins...

[Show more]

Preview 4 out of 31  pages

  • August 2, 2024
  • 31
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • MASSACHUSETTS PLUMBERS JOURNEYMAN
  • MASSACHUSETTS PLUMBERS JOURNEYMAN
avatar-seller
MASSACHUSETTS PLUMBERS JOURNE YMAN : EXAM A combination waste -and-vent system is limited to the installation of - floor drains and sinks A permit from the _________ & ________ shall be obtained for the installation of an unvented gas fired space room heater. - Fire Dept. & Gas Inspector 1. Any structure, in which a building drain is installed, shall have as a minimum one full size main stack vent or a vent stack no less than - three inches in diameter 2. Small Pipe - 12 Inch Clearance. Cleanouts smaller than three inches shall be so installed that there is a - 12-inch clearance for the purpose of clearing stoppages. A _________ shall be located on rigid piping up stream of a flexible connector. - Accessible Gas Shut -Off A backflow preventer or vacuum breaker shall be installed on all sillcocks, hose connections and wall hydrants including faucets that incorporate a_________________? - a hose thread outlet A Brass closet flange shall have a minimum thickness of - 1/8" A combination plumbing fixture may be installed on one trap - -one compartment is not more than six inches deeper than the other -the waste outlets are not more than 30 inches apart. A combination waste and vent system shall not be used unless - no other system is possible or practicable, and only then after Special -permission is granted by the Board A dead end may be used to? - Extend the cleanout. 3. Where only two fixtures that are battery waste and vented are installed on the same branch, a relief vent as described above shall - not be required A kitchen sink shall not waste into any horizontal drain line that receives the waste from a - bathtub or similar flat bottom fixture that is smaller than three inches in diameter A manometer used to measure gas shall be calibrated in ___________. - Inches of water column ___________________are required on the hot and cold water inlets to the automatic central control mixing valve - Check Valves A safe waste pan shall be installed under a water heater or hot water storage tank that is installed in a position - in a position elevated above any occupied space A sleeve for CSST tubing shall be schedule _______ black or galvanized pipe. - 40 A sleeve for CSST tubing shall extend a minimum of ________ in. from the top of a finished floor or deck. - 6 A suds relief vent shall connect to the laundry main drain a minimum of - 40 pipe diameters downstream from the base of the laundry stack. A waste and vent that serves a kitchen sink, a garbage disposal, a dish washer, or other fixture installed for culinary use, or one that receives the discharge from a clothes washing machine may not serve as a - wet vent for any other fixture. a. All two -piece toilets shall be low consumption toilets, which use a maximum of - 1.6 gallons per flush Air Gap (Drainage System). - The unobstructed vertical distance through the free atmosphere between the outlet of a waste pipe and the flood level rim of the receptacle into which the waste discharges. Air All area drains shall be connected to the - storm water drainage system All establishments summarized in 248 CMR 10.09(2)(a), (restaurants, cafeterias, hotels...) that are served by a municipal sanitary sewer and can seat 20 patrons or more shall incorporate - food waste grinders All floor drains and trough drains shall be installed with a, readily accessible - automatic trap -
priming device All food -waste grinder units shall be provided with an - adequate supply of cold water from faucets at sufficient flow rate to insure proper functioning of the unit. All hospitals shall have - dual services installed in a manner to provide an uninterrupted supply of water in case of a water main break. All indirect waste piping shall discharge into the building sanitary or storm drainage system through - an air gap or air break All strainer plates on drain inlets shall be designed and installed so that the diameter of the opening is no greater than...? - 1/2" All sumps and ejectors shall be protected against backflow and backpressure from the building sewer or building drain by installing - a backwater or check valve in the discharge pipe from the ejector or sump pump Allowable Materials. (a) When installing fittings or piping for renovations or alterations within an existing soil stack, waste stack, vent stack or drain, the fitting or piping shall be of the - same material as the existing stack or drain and be compliant with a joining method outlined in 248 CMR 10.07 An indirect waste stack receiving the discharge from fixtures on - two or more floors shall be extended to the outer air as required for a stack vent Any fixture or piece of equipment to be indirectly wasted that has a waste outlet smaller than 1¼ inches in diameter shall be connected to an indirect waste pipe - one size larger than said outlet. Approved shall mean __________________. - Accepted by the authority having jurisdiction As in the use of color bands, tags shall be attached to pipes at intervals of not more than - 25 feet and at either side of points where pipes pass through walls and above and below points where pipes pass through floors or roofs Automatic vent fittings are not permitted, except with - Special -permission from the Board. Automatic Vent Fittings. 1. The automatic vent fitting shall be installed in the vertical position not less than - six inches above the crown of the trap it serves. Backfilling. 1. Until the crown of the pipe is covered by at - at least two feet of tamped earth considerable care shall be exercised in backfilling trenches Backfilling. 1. Until the crown of the pipe is covered by at lest____________ feet of tamped earth considerable care shall be exercised in backfilling trenches - two feet Barometric Loop. - A vertical loop of pipe, rising to a height sufficient to prevent back -siphonage from occurring in the potable water supply pipe. (Approximately 35 feet, depending on the weight of the atmosphere.)

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICMATERIALS. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for CA$11.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75759 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
CA$11.49
  • (0)
  Add to cart