Tamper-resistant receptacles are not required in ___. - answer correctional facilities

A plug with a two-foot-long cord is permitted for a ___. - answer waste disposer

Plug-in-type overcurrent protection devices or plug-in type main lug assemblies that are
___ and used to terminate field-installed ungrounded supply conductors shall be
secured in place by an additional fastener that requires other than a pull to release the
device from the mounting means on the panel. - answerback fed

Panelboards equipped with snap switches rated ___ amperes or less shall have
overcurrent protection of 200 amperes or less. - answer30

The minumum clearance between a surface mounted fluorescent luminaire installed on
the wall above the door and the nearest point of a storage space in a clothes closet is
___. - answer6 inches

A recessed luminaire that is not identified for contact with insulation shall have all
recessed parts spaced not less than ___ from combustible materials. - answer1/2"

In which location is lighting track permitted? - answer4 feet above the floor operating on
24 volts.

A snap switch shall not be grouped or ganged in enclosures with other snap switches,
receptacles or similiar devices, unless they are arranged so that the voltage between
adjacent devices does not exceed ___, or unless they are installed in enclosures
equipped with identified, securely installed barriers between adjacent devices. -
answer300 volts

Three-way and four-way switches shall be wired so that all switching is done only in the
___ conductors. - answerungrounded

In general, flexible cords are not permitted in which application? - answerattached to
building surfaces

What is the allowable ampacity for 18 AWG fixture wire? - answer6 amperes

A non-grounding-type receptacle(s) shall be permitted to be replaced with a ground-fault
interupter-type of receptacle(s). These receptacles or their cover plates shall be marked
___. - answerCaution: No Grounding Means (correct would be No equipment means
being checked)

, Typical building construction utilizes concrete for ___ and foundations. - answerall of
these

Cement is a principal ingredient of concrete. Allowing wet concrete to touch your skin is
___. - answerhazardous

If you are working with wet cement products, you must wear ___. - answerI, II and III

When pieces of rebar protrude from concrete, these must be guarded to prevent
workers from being impaled upon them. Acceptable methods of guarding include
capping the rebar with ___. - answerlarge orange caps with steel inserts

You should not use scaffolding erected by other trades unless it has been inspected by
a competent person. - answerTrue

Working around concrete mixer trucks can be dangerous when ___. - answereither a or
b

When sizing the branch-circuit short-circuit and ground-fault protection for a three-phase
AC motor, you would use Table ___. - answer430.250

Conductors that supply a single motor used in a continuous duty application shall have
an ampacity of ___% of the motor FLA. - answer125

The conductors for a 30-minute-rated motor, used for intermittent duty, are permited to
have a rating ___% of the motor nameplate current rating. - answer90

For a hermetic refrigerant motor-compressor, the ampere rating of the disconnect shall
be ___% of the nameplate rating or the branch circuit selection current, whichever is
greater. - answer115

Overcurrent protection for generators is found in ___. - answer445.12

The walls and roofs of transformer vaults shall have a fire rating of ___ hours. - answer3

The minimum height of the door sill for a transformer vault is ___ inches. -
answer(wrong)

For one-family or two-family dwellings, a disconnecting means or its remote control for a
stationary battery system shall be located at a(n) ___ location outside the building. -
answerreadily accessible

A non-permit confined space does not contain any hazard capable of causing ___. -
answereither I or II

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for CA$20.92. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75323 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
CA$20.92
  • (0)
  Add to cart