[Mostrar más]When recovering refrigerant from a household refrigerator who's compressor does not run, it is 
recommended that a low and high side access valves be installed because: - it can help speed of 
recovery and required recovery effiency 
Recovery equipemnt used for the service or repair of small applia...
Vista previa 1 fuera de 4 páginas
Añadir al carritoWhen recovering refrigerant from a household refrigerator who's compressor does not run, it is 
recommended that a low and high side access valves be installed because: - it can help speed of 
recovery and required recovery effiency 
Recovery equipemnt used for the service or repair of small applia...
The primary water source for cooling the condenser of a water-cooled recovery unit is: - local 
municipal water supply 
Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - replacement 
of evaporator coil 
According to ASHRAE Guideline 3-1996, if the pressure in a syste...
Vista previa 2 fuera de 13 páginas
Añadir al carritoThe primary water source for cooling the condenser of a water-cooled recovery unit is: - local 
municipal water supply 
Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - replacement 
of evaporator coil 
According to ASHRAE Guideline 3-1996, if the pressure in a syste...
A __________ recovery device can be use for type 1 small appliance applications or type 2 applications if 
the total charge is below 15 pounds. - System dependent 
Always _____________ when connecting or disconnecting refrigeration hoses. - 1.) wear safety 
eyewear and butyl-lined gloves 2.) verify ...
Vista previa 2 fuera de 5 páginas
Añadir al carritoA __________ recovery device can be use for type 1 small appliance applications or type 2 applications if 
the total charge is below 15 pounds. - System dependent 
Always _____________ when connecting or disconnecting refrigeration hoses. - 1.) wear safety 
eyewear and butyl-lined gloves 2.) verify ...
Once you take the EPA exam, you must memorize all regulations because they will stay the same forever. 
t or f? - False 
What is the primary source of chlorine in the stratosphere? - Emissions of refrigerant chemicals 
such as CFCs and HCFCs by humans 
As technicians, we must follow and be up to dat...
Vista previa 1 fuera de 2 páginas
Añadir al carritoOnce you take the EPA exam, you must memorize all regulations because they will stay the same forever. 
t or f? - False 
What is the primary source of chlorine in the stratosphere? - Emissions of refrigerant chemicals 
such as CFCs and HCFCs by humans 
As technicians, we must follow and be up to dat...
Containers designed "refillable" by DOT are used for transporting recovered pressurized refrigerant to? - 
To meet safety requirements. 
What is the best proof that CFC's are in the stratosphere? - The measurement of CFC's in air 
samples from the stratosphere. 
The size (capacity) of the vacuum...
Vista previa 1 fuera de 3 páginas
Añadir al carritoContainers designed "refillable" by DOT are used for transporting recovered pressurized refrigerant to? - 
To meet safety requirements. 
What is the best proof that CFC's are in the stratosphere? - The measurement of CFC's in air 
samples from the stratosphere. 
The size (capacity) of the vacuum...
The EPA regulations require that leaking commercial or industrial process refrigeration equipment must 
be repaired when the leak rate exceeds _____ of the charge per year. - 35% 
The proper charging method for blended (non-azeotropic) refrigerants (400 Series) is to use a remove 
the charge from th...
Vista previa 2 fuera de 7 páginas
Añadir al carritoThe EPA regulations require that leaking commercial or industrial process refrigeration equipment must 
be repaired when the leak rate exceeds _____ of the charge per year. - 35% 
The proper charging method for blended (non-azeotropic) refrigerants (400 Series) is to use a remove 
the charge from th...
heat added to refridgerant vapor that causes its temperature to rise above its saturartion temp - 
Subheated refridgerant 
causes change of state, cannot be felt, cannot be measured with a thermometer, but does not cause a 
change in temperature. - Latent Heat 
a high capacity vacuum pump and short,...
Vista previa 2 fuera de 8 páginas
Añadir al carritoheat added to refridgerant vapor that causes its temperature to rise above its saturartion temp - 
Subheated refridgerant 
causes change of state, cannot be felt, cannot be measured with a thermometer, but does not cause a 
change in temperature. - Latent Heat 
a high capacity vacuum pump and short,...
To recover refrigerant is to: - Remove refrigerant is any condition from a system in either an active 
or passive manner, and store it in an external container without necessarily testing or processing. 
The required evacuation level for recovering refrigerant from a low pressure appliance with a re...
Vista previa 2 fuera de 10 páginas
Añadir al carritoTo recover refrigerant is to: - Remove refrigerant is any condition from a system in either an active 
or passive manner, and store it in an external container without necessarily testing or processing. 
The required evacuation level for recovering refrigerant from a low pressure appliance with a re...
What are Cooling Towers? - They are heat removal devices used to transfer process waste heat to 
the atmosphere. 
The most efficient method of leak checking a charged low-pressure system is to use? - Controlled 
hot water or heater blankets 
In relation to the three "R's" what is Reclaim? - To pr...
Vista previa 2 fuera de 7 páginas
Añadir al carritoWhat are Cooling Towers? - They are heat removal devices used to transfer process waste heat to 
the atmosphere. 
The most efficient method of leak checking a charged low-pressure system is to use? - Controlled 
hot water or heater blankets 
In relation to the three "R's" what is Reclaim? - To pr...
Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!
Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.
Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.
Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICMATERIALS. Stuvia facilitates payment to the seller.
No, you only buy this summary for $15.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
45,681 summaries were sold in the last 30 days
Founded in 2010, the go-to place to buy summaries for 14 years now