Thhn - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Thhn? On this page you'll find 319 study documents about Thhn.
Page 3 out of 319 results
Sort by
-
Journeyman Electrician Practice Test | Questions with 100% Correct Answers | Latest Update 2024 | Verified
- Exam (elaborations) • 17 pages • 2024
-
- $9.99
- + learn more
Journeyman Electrician Practice Test | Questions with 100% Correct Answers | Latest Update 2024 | Verified 
Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - 
THHN 
conductors with THHN insulation are approved for use in dry and damp locations only and 
conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet 
locations. 
Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 
120/240 volt, sin...
-
Journeyman Practice Test Questions and Answers
- Exam (elaborations) • 16 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman Practice Test Questions and Answers 
Conductors with _____ marked on the insulation are NOT approved for use in a wet 
location. -Answer-THHN 
conductors with THHN insulation are approved for use in dry and damp locations only 
and conductors with THWN, THHW, and THW insulation are recognized for use in dry 
and wet locations. 
Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 
120/240 volt, single-phase, electrical system from the local utility co...
-
IEC Final Exam Year 1 Questions and Answers 2024
- Exam (elaborations) • 34 pages • 2024
- Available in package deal
-
- $12.99
- + learn more
What is the result if the neutral wire becomes open on a multiwire circuit having unequal loads? 
a. 
The load of higher resistance would overheat and probably be damaged. 
b. 
The load of lesser resistance would overheat and probably be damaged. 
c. 
No effect until one load is turned off or opens. 
d. 
No effect. 
a. 
The load of higher resistance would overheat and probably be damaged. 
 
 
Circuits 7 and 9 share a neutral. This is a multiwire branch circuit. If Ckt. 7 is drawing 13 amps and ...
-
NICET 2 exam 2024 with 100% correct answers
- Exam (elaborations) • 9 pages • 2024
-
Available in package deal
-
- $16.49
- + learn more
Where located above floor (within 2.1m or 7ft.) cables shall be securely fastened at intervals of?Answer - not more than 18 inches 
 
Which cable types can be installed in fireproof riser shafts?Answer - FPLP, FPLR, and FPL 
 
How many THHN conductors can fit in a 3/4 size Rigid PVC conduit?Answer - 17 
 
This is the defined as the height from the continuous floor of a room to the continuous ceiling of a room or space?Answer - Ceiling height 
 
The visible annunciation of the location of ope...
-
Journeyman Electrician Practice Test Latest Update Graded A+
- Exam (elaborations) • 20 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
Journeyman Electrician Practice Test Latest Update Graded A+ 
Conductors with _____ marked on the insulation are NOT approved for use in a wet location. THHN 
conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. 
Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 120/240 volt, single-phase, electrical system from the local utility ...
Get paid weekly? You can!
-
Nicet Level 1 Study Guide | 150 Questions with 100% Correct Answers | Verified | Latest Update 2024
- Exam (elaborations) • 17 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water 
level _____________from the required level 
(NFPA 72, Table 14.4.3.2 17 (j) (4) - rises or falls over 3 inches 
If combination audible/visible appliances are installed the location of the installed appliance shall be 
determined by the requirements of _______. 
(Nfpa 72 18.4.8.1) - the visible appliance 
What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT? 
(...
-
Journeyman Electrician Practice Test | Questions and Correct Answers | Latest Update 2024/2025
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman Electrician Practice 
Test | Questions and Correct 
Answers | Latest Update 
2024/2025 
Conductors with _____ marked on the insulation are NOT approved for 
use in a wet location. - Answer -THHN 
conductors with THHN insulation are approved for use in dry and damp 
locations only and conductors with THWN, THHW, and THW insulation 
are recognized for use in dry and wet locations. 
Given: A one-family dwelling unit with a demand load of 200 amperes is 
supplied with a 120/240 volt, sing...
-
IEC Lesson 118 - First Semester Final Exam Questions and Answers Latest (2024 / 2025) (Verified Answers)
- Exam (elaborations) • 10 pages • 2024
-
- $13.49
- + learn more
. 23.5 V =	mV 
ANS 23,500 
2.	512 cubic inches =	cubic feet 
ANS .2963 
3.	A 20-ampere, 125-volt single receptacle installed in a dwelling garage for a freezer would require GFCI protection. 
ANS True 
4.	A 240-volt branch circuit supplies a resistive heating load of 10 amps. The distance from the panel to the heater is 200'. Using 12 AWG THHN copper, what is the voltage drop on the wire? Use K = 12. 
ANS 7.35 (Vd = 2KIL ÷ cma = (2)(12)(10)(200) ÷ 6530 = 7.35 volts) 
5.	A GFCI receptacle or c...
-
Journeyman practice test 100% Correct!!
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $15.99
- + learn more
There are six conductors in a raceway connected to 75° rated breakers. Each wire has a 70-amp load using 
THHN conductors. The minimum size conductor used are #__________ AWG. 
a. 4 
b. 6 
c. 8 
d. 10 - ANSWERa 
 
Thermal insulation shall not be installed within __________ inch(es) of recessed fixtures. 
a. 1⁄2 
b. 3⁄4 
c. 2 
d. 3 - ANSWERd 
 
A 1-inch conduit contains three 3-wire circuits. All conductors are #10 TW. Each circuit consist of two 
phase conductors, one grounded conductor, an...
-
Journeymans test exam 2024 with verified solutions
- Exam (elaborations) • 15 pages • 2024
-
- $15.49
- + learn more
Thermal insulation shall not be installed within ______ inch(es) of recessed fixtures correct answers3 
 
An AC system of 50 to 1000 volts shall be grounded if maximum voltage to ground does not exceed ____ volts. correct answers150 
 
The underwater light fixture shall be at least ____ inches below water level. correct answers18 
 
A junction box for the 120 volt wet-niche fixture shall be at least ____ inches above the ground correct answers4 
 
A GFCI protected ____ receptacle for the pump mo...