Package deal
MEDICAL PHYSICS TESTS COMPILATION BUNDLE
MEDICAL PHYSICS TESTS COMPILATION BUNDLE
[Show more]MEDICAL PHYSICS TESTS COMPILATION BUNDLE
[Show more]medical physics final exam Questions With Complete Solutions
Preview 2 out of 15 pages
Add to cartmedical physics final exam Questions With Complete Solutions
Medical Physics ABR Part 1 Clinical (Basic Anatomy and Radiobiology for the Medical Physicists) Questions With Complete Solutions
Preview 2 out of 15 pages
Add to cartMedical Physics ABR Part 1 Clinical (Basic Anatomy and Radiobiology for the Medical Physicists) Questions With Complete Solutions
1x sold
Medical Physics Jurisprudence Exam TMB - Study Guide 2023 Questions With Complete Solutions
Preview 2 out of 13 pages
Add to cartMedical Physics Jurisprudence Exam TMB - Study Guide 2023 Questions With Complete Solutions
Medical Physics MCQS Questions With Complete Solutions
Preview 4 out of 49 pages
Add to cartMedical Physics MCQS Questions With Complete Solutions
Virtual Source Distance Equation correct answer: (R100/R110) = ((VSD+Dmax+gap)/(VSD+Dmax))^2 
 
Dose Delivered at Time correct answer: D(t) = D0(rate)/decay_constant*(1-e^(-dc(t)) 
D(t) = 1.44*D0(rate)*(1-e^(.693/T1/2*t)) 
 
TG-43 Geometry Function (Non-perpendicular) correct answer: Gl = Beta/(L...
Preview 4 out of 45 pages
Add to cartVirtual Source Distance Equation correct answer: (R100/R110) = ((VSD+Dmax+gap)/(VSD+Dmax))^2 
 
Dose Delivered at Time correct answer: D(t) = D0(rate)/decay_constant*(1-e^(-dc(t)) 
D(t) = 1.44*D0(rate)*(1-e^(.693/T1/2*t)) 
 
TG-43 Geometry Function (Non-perpendicular) correct answer: Gl = Beta/(L...
Physics correct answer: The science of space, time, matter, energy and their interactions at the most fundamental level. 
 
Time correct answer: Dimension that relates to when events occur. 
 
Matter correct answer: Anything that occupies space and has mass. 
 
Energy correct answer: The ability...
Preview 4 out of 44 pages
Add to cartPhysics correct answer: The science of space, time, matter, energy and their interactions at the most fundamental level. 
 
Time correct answer: Dimension that relates to when events occur. 
 
Matter correct answer: Anything that occupies space and has mass. 
 
Energy correct answer: The ability...
ABR Medical Physics Part 3 - TG Reports/MPPG/CFR Questions With Complete Solutions
Preview 2 out of 7 pages
Add to cartABR Medical Physics Part 3 - TG Reports/MPPG/CFR Questions With Complete Solutions
CONDITIONAL Complete - Imaging Medical Physics (Full Set of Imaging Study Cards for Therapuetic Medical Physics ABR Part 3 Oral Exams) Questions With Complete Solutions
Preview 4 out of 54 pages
Add to cartCONDITIONAL Complete - Imaging Medical Physics (Full Set of Imaging Study Cards for Therapuetic Medical Physics ABR Part 3 Oral Exams) Questions With Complete Solutions
Medical Physics Exam 1 Questions With Complete Solutions
Preview 3 out of 18 pages
Add to cartMedical Physics Exam 1 Questions With Complete Solutions
Medical Physics Study Set Questions And Answers
Preview 2 out of 8 pages
Add to cartMedical Physics Study Set Questions And Answers
Medical Physics Questions And Answers With Complete Solutions
Preview 2 out of 10 pages
Add to cartMedical Physics Questions And Answers With Complete Solutions
ABR Medical Physics Part 3 - Rules of Thumb Questions With Complete Solutions
Preview 2 out of 10 pages
Add to cartABR Medical Physics Part 3 - Rules of Thumb Questions With Complete Solutions
ABR part 1 medical physics Questions And Answers With Complete Solutions
Preview 4 out of 39 pages
Add to cartABR part 1 medical physics Questions And Answers With Complete Solutions
Medical Physics ABR part 1 constants and equations
Preview 1 out of 4 pages
Add to cartMedical Physics ABR part 1 constants and equations
Ion Chamber - Operational Theory correct answer: a) Cavity of air is surrounded by two electrodes charged to around 300 Volts 
b) Incident radiation creates ion pairs in air volume 
c) Ions are swept away by the potential between the plates 
d) Charge of current is read by an electrometer 
 
Ion Ch...
Preview 1 out of 3 pages
Add to cartIon Chamber - Operational Theory correct answer: a) Cavity of air is surrounded by two electrodes charged to around 300 Volts 
b) Incident radiation creates ion pairs in air volume 
c) Ions are swept away by the potential between the plates 
d) Charge of current is read by an electrometer 
 
Ion Ch...
The heat capacity of a CT x-ray tube anode (kJ) is most likely: 
a. 0.4 
b. 4 
c. 40 
d. 400 
e. 4,000 correct answer: Answer (e) 
The typical anode heat capacity of a modern CT x-ray tube anode is 4,000 kJ (4 MJ) 
 
The power (kW) applied to a modern CT x-ray tube is most likely: 
a. 1 
b. 3 
c. 1...
Preview 2 out of 8 pages
Add to cartThe heat capacity of a CT x-ray tube anode (kJ) is most likely: 
a. 0.4 
b. 4 
c. 40 
d. 400 
e. 4,000 correct answer: Answer (e) 
The typical anode heat capacity of a modern CT x-ray tube anode is 4,000 kJ (4 MJ) 
 
The power (kW) applied to a modern CT x-ray tube is most likely: 
a. 1 
b. 3 
c. 1...
In a 1.5T MRI, if the temperature is 22C, what is the ratio of 
 
spins parallel to B₀ to those antiparallel to B₀? correct answer: 1.00001 
 
A 10kg block of ice is at 15⁰F. How much energy must be transferred in order to heat it to a 55⁰F puddle of water? (specific heat of water is 4186 ...
Preview 2 out of 12 pages
Add to cartIn a 1.5T MRI, if the temperature is 22C, what is the ratio of 
 
spins parallel to B₀ to those antiparallel to B₀? correct answer: 1.00001 
 
A 10kg block of ice is at 15⁰F. How much energy must be transferred in order to heat it to a 55⁰F puddle of water? (specific heat of water is 4186 ...
Vertebral Level of : 
A: Clavicle 
B: Scapula correct answer: A: C7-T1 
B: T2-T7 
 
What is the master gland and where is it located? correct answer: Pituitary - base of the brain (between the optic nerves) - Hormone production is stimulated by hypothalmus 
 
What does the pancreas do? correct a...
Preview 4 out of 81 pages
Add to cartVertebral Level of : 
A: Clavicle 
B: Scapula correct answer: A: C7-T1 
B: T2-T7 
 
What is the master gland and where is it located? correct answer: Pituitary - base of the brain (between the optic nerves) - Hormone production is stimulated by hypothalmus 
 
What does the pancreas do? correct a...
TG-51 def: %dd(10)x correct answer: the photon component of the photon beam percentage depth-dose at 10 cm depth in a 10x10 cm2 field on the surface of a water phantom at an SSD of 100 cm 
 
TG-51 def: %dd(10) correct answer: the measured photon beam percentage depth dose at 10 cm depth in a 10x10...
Preview 4 out of 102 pages
Add to cartTG-51 def: %dd(10)x correct answer: the photon component of the photon beam percentage depth-dose at 10 cm depth in a 10x10 cm2 field on the surface of a water phantom at an SSD of 100 cm 
 
TG-51 def: %dd(10) correct answer: the measured photon beam percentage depth dose at 10 cm depth in a 10x10...
US attenuation rule of thumb correct answer: 0.5 dB/cm*MHz in soft tissue 
 
Lens dose is calculated at what depth? correct answer: 0.3 cm 
 
How many HVLs in a collimator head? correct answer: 2% transmission, so 0.02=2^(-n)-> n=5.6, 6 HVL 
 
Temperature and pressure correction correct answer...
Preview 2 out of 7 pages
Add to cartUS attenuation rule of thumb correct answer: 0.5 dB/cm*MHz in soft tissue 
 
Lens dose is calculated at what depth? correct answer: 0.3 cm 
 
How many HVLs in a collimator head? correct answer: 2% transmission, so 0.02=2^(-n)-> n=5.6, 6 HVL 
 
Temperature and pressure correction correct answer...
How to make tangent beams coplanar correct answer: Divergence = arctan((0.5 * width)/distance)) 
 
e- density correct answer: e- density = (density*Na*Z)/Aw 
 
Percent photon contamination of e- beam with Energy correct answer: [6e = 1 ....... 20e = 5] * 0.6% 
 
Virtual e- source distance calcula...
Preview 2 out of 5 pages
Add to cartHow to make tangent beams coplanar correct answer: Divergence = arctan((0.5 * width)/distance)) 
 
e- density correct answer: e- density = (density*Na*Z)/Aw 
 
Percent photon contamination of e- beam with Energy correct answer: [6e = 1 ....... 20e = 5] * 0.6% 
 
Virtual e- source distance calcula...
Co-60 dmax - 0.5cm 
 
6x dmax - 1.5cm 
 
10x dmax - 2.5cm 
 
18x dmax - 3.5cm 
 
% attenuation in water for: 
6MV 
10MV 
18MV - 6MV=3%/cm 
10MV=2.5%/cm 
18MV=2%/cm 
 
Electron attenuation in AIR - 2%/cm 
105 to 110 SSD change in output ~10% 
 
Electron attenuation in WATER and LEAD - 2MeV/cm for Wat...
Preview 2 out of 13 pages
Add to cartCo-60 dmax - 0.5cm 
 
6x dmax - 1.5cm 
 
10x dmax - 2.5cm 
 
18x dmax - 3.5cm 
 
% attenuation in water for: 
6MV 
10MV 
18MV - 6MV=3%/cm 
10MV=2.5%/cm 
18MV=2%/cm 
 
Electron attenuation in AIR - 2%/cm 
105 to 110 SSD change in output ~10% 
 
Electron attenuation in WATER and LEAD - 2MeV/cm for Wat...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Classroom. Stuvia facilitates payment to the seller.
No, you only buy these notes for £28.78. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
57413 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now