[Show more]#2 fuel oil - ANSWER-most frequently used and burns at 140,000 BTU per gallon 
 
air bend - ANSWER-regulates the volume (amount) by changing it to a spray of tiny droplets 
 
atomizing - ANSWER-vaporizing liquid oil (turning it into gas) by changing it to a spray of tiny droplets 
 
bleeder - ANSWER...
Preview 1 out of 2 pages
Add to cart#2 fuel oil - ANSWER-most frequently used and burns at 140,000 BTU per gallon 
 
air bend - ANSWER-regulates the volume (amount) by changing it to a spray of tiny droplets 
 
atomizing - ANSWER-vaporizing liquid oil (turning it into gas) by changing it to a spray of tiny droplets 
 
bleeder - ANSWER...
Max safety timing on a primary control - ANSWER-15 seconds 
 
Safety control circuits shall be - ANSWER-2-wire, one side grounded, with nominal voltage not exceeding 150v 
 
Crankcase/used oil may only be used in - ANSWER-Commercial/industrial setting. Or in a appliance specifically designed to do s...
Preview 2 out of 6 pages
Add to cartMax safety timing on a primary control - ANSWER-15 seconds 
 
Safety control circuits shall be - ANSWER-2-wire, one side grounded, with nominal voltage not exceeding 150v 
 
Crankcase/used oil may only be used in - ANSWER-Commercial/industrial setting. Or in a appliance specifically designed to do s...
leak. - ANSWER-The answer is EXCESS ELEVATION CHANGE. Excessive elevation change is not a common oil supply line problem. A fuel filter is needed in this arrangement. 
 
All of the following are common vent connector issues on oil furnaces except 
 
A) 
poor connection to chimney. 
 B) 
poor support...
Preview 2 out of 7 pages
Add to cartleak. - ANSWER-The answer is EXCESS ELEVATION CHANGE. Excessive elevation change is not a common oil supply line problem. A fuel filter is needed in this arrangement. 
 
All of the following are common vent connector issues on oil furnaces except 
 
A) 
poor connection to chimney. 
 B) 
poor support...
whats a good defintion for viscosity - ANSWER-viscosity is resistance to flow 
 
whats the flash point of number 2 heating fuel - ANSWER-115 degrees 
 
whats the pour point of number 2 heating fuel - ANSWER-17 degress farenheit 
 
what is a btu - ANSWER-the amount of energy to raise one pound of wat...
Preview 2 out of 7 pages
Add to cartwhats a good defintion for viscosity - ANSWER-viscosity is resistance to flow 
 
whats the flash point of number 2 heating fuel - ANSWER-115 degrees 
 
whats the pour point of number 2 heating fuel - ANSWER-17 degress farenheit 
 
what is a btu - ANSWER-the amount of energy to raise one pound of wat...
What causes oil tanks to rust? - ANSWER-the air int he tank condenses and forms water 
 
Where will the oil filter be located in the oil supply line? - ANSWER-Between the tank and the oil burner 
 
NAAHT a function of the primary control on an oil burner - ANSWER-to sense air temperatures in furnace...
Preview 1 out of 1 pages
Add to cartWhat causes oil tanks to rust? - ANSWER-the air int he tank condenses and forms water 
 
Where will the oil filter be located in the oil supply line? - ANSWER-Between the tank and the oil burner 
 
NAAHT a function of the primary control on an oil burner - ANSWER-to sense air temperatures in furnace...
The nozzle flow rate, spray angle and pattern are directly related to: - ANSWER-All of the above - tangential slots, swirl chamber, orifice 
 
Cold oil or high viscosity problems may be eliminated by - ANSWER-Increasing pump pressure and reducing nozzle size & installing a nozzle line pre-heater 
 
...
Preview 2 out of 8 pages
Add to cartThe nozzle flow rate, spray angle and pattern are directly related to: - ANSWER-All of the above - tangential slots, swirl chamber, orifice 
 
Cold oil or high viscosity problems may be eliminated by - ANSWER-Increasing pump pressure and reducing nozzle size & installing a nozzle line pre-heater 
 
...
Tank sizes - ANSWER-Tanks are available from 100 gallons to 1000 gallons 
 
How much of the annual oil consumption should the tanks hold - ANSWER-1/3 
 
Underground tanks - ANSWER-Tanks installed on the ground must be protected against corrosion, most popular types are the STI - p3 tanks in fibergla...
Preview 1 out of 4 pages
Add to cartTank sizes - ANSWER-Tanks are available from 100 gallons to 1000 gallons 
 
How much of the annual oil consumption should the tanks hold - ANSWER-1/3 
 
Underground tanks - ANSWER-Tanks installed on the ground must be protected against corrosion, most popular types are the STI - p3 tanks in fibergla...
Squirrel Cage - ANSWER-Cylinder shaped fan assembly used to move air 
 
Coupling - ANSWER-A device for joining 2 fluid-flow lines 
 
Oil Pump - ANSWER-Transfers oil from the supply tank, increases pump pressure to 100/140 psig 
 
Cad Cell - ANSWER-A device containing cadmium sulfide used to prove th...
Preview 1 out of 2 pages
Add to cartSquirrel Cage - ANSWER-Cylinder shaped fan assembly used to move air 
 
Coupling - ANSWER-A device for joining 2 fluid-flow lines 
 
Oil Pump - ANSWER-Transfers oil from the supply tank, increases pump pressure to 100/140 psig 
 
Cad Cell - ANSWER-A device containing cadmium sulfide used to prove th...
The reducing of oil into very small particles is termed 
 
a) fluidization 
 
b) fractionation 
 
c) turbulence 
 
d) atomization 
 
e) distillation - ANSWER-d 
 
Before atomization can occur, heavy oils are heated to 
approximately 
 
a) 203 degrees C 
 
b) 95 degrees C 
 
c) 115 degrees C 
 
d) 75...
Preview 2 out of 9 pages
Add to cartThe reducing of oil into very small particles is termed 
 
a) fluidization 
 
b) fractionation 
 
c) turbulence 
 
d) atomization 
 
e) distillation - ANSWER-d 
 
Before atomization can occur, heavy oils are heated to 
approximately 
 
a) 203 degrees C 
 
b) 95 degrees C 
 
c) 115 degrees C 
 
d) 75...
What is an oil safety valve required - ANSWER-On existing installations when a burner, boiler, furnace or tank is replaced 
 
When must you install a draft regulator - ANSWER-When not exempted by the manufacturer 
 
As of January 1 2014, max safety timing for an oil burner safety switch must be no m...
Preview 3 out of 19 pages
Add to cartWhat is an oil safety valve required - ANSWER-On existing installations when a burner, boiler, furnace or tank is replaced 
 
When must you install a draft regulator - ANSWER-When not exempted by the manufacturer 
 
As of January 1 2014, max safety timing for an oil burner safety switch must be no m...
Regarding the replacement of a burner on an approved appliance: 
a) any burner approved and certified by the manufacturer of the appliance can be used 
b) any approved burner can be field approved by TSSA 
c) the installer must ensure that the appliance is in good condition before replacing the burn...
Preview 2 out of 8 pages
Add to cartRegarding the replacement of a burner on an approved appliance: 
a) any burner approved and certified by the manufacturer of the appliance can be used 
b) any approved burner can be field approved by TSSA 
c) the installer must ensure that the appliance is in good condition before replacing the burn...
On a "no heat" service call for an oil-fired furnace, what is the main safety precaution that the technician must take before attempting to fire the oil furnace? - ANSWER-check the combustion chamber for liquid oil 
 
On start-up of an oil unit, the technician's smoke test shows the unit to have ...
Preview 1 out of 3 pages
Add to cartOn a "no heat" service call for an oil-fired furnace, what is the main safety precaution that the technician must take before attempting to fire the oil furnace? - ANSWER-check the combustion chamber for liquid oil 
 
On start-up of an oil unit, the technician's smoke test shows the unit to have ...
What is the size of an air vent on an oil storage tank? - ANSWER-1 1/4" 
 
What safety feature is used on an inside oil storage tank that will protect against a house fire? - ANSWER-a fuse-type globe valve 
 
What effect, if any, would a decrease of primary air have on combustion? - ANSWER-It would...
Preview 2 out of 9 pages
Add to cartWhat is the size of an air vent on an oil storage tank? - ANSWER-1 1/4" 
 
What safety feature is used on an inside oil storage tank that will protect against a house fire? - ANSWER-a fuse-type globe valve 
 
What effect, if any, would a decrease of primary air have on combustion? - ANSWER-It would...
The purpose of the gauge glass on steam boiler is what? - ANSWER-tells how much water is in boiler 
 
What is also on a steam heating system that tells how much water is in it? - ANSWER-pressure gauge that reads from 0 to 15 psi steam safety valve 
 
When there is a call for heat what happens to a s...
Preview 1 out of 2 pages
Add to cartThe purpose of the gauge glass on steam boiler is what? - ANSWER-tells how much water is in boiler 
 
What is also on a steam heating system that tells how much water is in it? - ANSWER-pressure gauge that reads from 0 to 15 psi steam safety valve 
 
When there is a call for heat what happens to a s...
Which of the three elements needed for combustion is the key element and final adjustment of an oil burner - ANSWER-Air 
 
What does the tertiary air that exists around the outside of the flame retention ring or thru the tertiary slots do - ANSWER-Ensures that and escaping oil spray will be burned 
...
Preview 1 out of 3 pages
Add to cartWhich of the three elements needed for combustion is the key element and final adjustment of an oil burner - ANSWER-Air 
 
What does the tertiary air that exists around the outside of the flame retention ring or thru the tertiary slots do - ANSWER-Ensures that and escaping oil spray will be burned 
...
What does InStep mean - ANSWER-The stack relay is operating properly 
 
How is combustion achieved - ANSWER-Atomization ,air ,ignition. 
 
What is the minimum size oil line for residential burners - ANSWER-3/8 inch 
 
How is safety timing checked on a stack relay switch - ANSWER-Remove the stack rel...
Preview 3 out of 18 pages
Add to cartWhat does InStep mean - ANSWER-The stack relay is operating properly 
 
How is combustion achieved - ANSWER-Atomization ,air ,ignition. 
 
What is the minimum size oil line for residential burners - ANSWER-3/8 inch 
 
How is safety timing checked on a stack relay switch - ANSWER-Remove the stack rel...
Boiler, High Pressure). - ANSWER-. A boiler for generating steam at pressures in excess of 15 psi (103 kPa), or for heating water to a temperature in excess of 250°F (121°C) or at a pressure in excess of 160 psi (1103 kPa). 
 
Boiler, Hot Water Supply. - ANSWER-A low-pressure hot water boiler havi...
Preview 2 out of 12 pages
Add to cartBoiler, High Pressure). - ANSWER-. A boiler for generating steam at pressures in excess of 15 psi (103 kPa), or for heating water to a temperature in excess of 250°F (121°C) or at a pressure in excess of 160 psi (1103 kPa). 
 
Boiler, Hot Water Supply. - ANSWER-A low-pressure hot water boiler havi...
3 systems of an oil burner - ANSWER-Every oil burner must have 
an air delivery system, 
a fuel delivery system, and 
an ignition system. 
 
How are oil burners classified? - ANSWER-Classified by the method used to prepare the fuel for combustion. 
 
Which type of oil burner dominates the resident...
Preview 1 out of 2 pages
Add to cart3 systems of an oil burner - ANSWER-Every oil burner must have 
an air delivery system, 
a fuel delivery system, and 
an ignition system. 
 
How are oil burners classified? - ANSWER-Classified by the method used to prepare the fuel for combustion. 
 
Which type of oil burner dominates the resident...
A ______ carbon dioxide content is usually caused by insufficient draft or an overfired burner 
 
 low 
 high - ANSWER-high 
 
A _______ stack thermometer is generally used to measure the flue gas temperature in oil heating system: 
 
 200/2000°F 
 100/1000°F 
 200/1000°F 
 100/2000°F - ANSWER-2...
Preview 1 out of 4 pages
Add to cartA ______ carbon dioxide content is usually caused by insufficient draft or an overfired burner 
 
 low 
 high - ANSWER-high 
 
A _______ stack thermometer is generally used to measure the flue gas temperature in oil heating system: 
 
 200/2000°F 
 100/1000°F 
 200/1000°F 
 100/2000°F - ANSWER-2...
vent pipes must be atleast ______ feet above or _______ feet below any window or door. they must also be _____ get away from property line to prevent sewer gas from drifting to neighbors house - ANSWER-3 feet above or 5 feet below door or window. 
3 feet from property line 
 
To make combustion effi...
Preview 1 out of 4 pages
Add to cartvent pipes must be atleast ______ feet above or _______ feet below any window or door. they must also be _____ get away from property line to prevent sewer gas from drifting to neighbors house - ANSWER-3 feet above or 5 feet below door or window. 
3 feet from property line 
 
To make combustion effi...
What size is the oil line for a residential burner? - ANSWER-3/8 
 
Largest oil capacity for residential without a license? - ANSWER-10,000 Gallons 
 
At what height ceiling would a second thermal switch be required? - ANSWER-12' 
 
A typical residential oil burner is also s/u to run Kerosene True?...
Preview 2 out of 9 pages
Add to cartWhat size is the oil line for a residential burner? - ANSWER-3/8 
 
Largest oil capacity for residential without a license? - ANSWER-10,000 Gallons 
 
At what height ceiling would a second thermal switch be required? - ANSWER-12' 
 
A typical residential oil burner is also s/u to run Kerosene True?...
A fuel oil storage tank cannot be installed: - ANSWER-In the furnace room 5 feet within heating unit 
 
What temperature does a thermal wheel automatically activate at - ANSWER-165°F 
 
Who inspects an oil burner installation - ANSWER-State fire marshal 
 
Any valve used on a oil burner install mus...
Preview 2 out of 8 pages
Add to cartA fuel oil storage tank cannot be installed: - ANSWER-In the furnace room 5 feet within heating unit 
 
What temperature does a thermal wheel automatically activate at - ANSWER-165°F 
 
Who inspects an oil burner installation - ANSWER-State fire marshal 
 
Any valve used on a oil burner install mus...
The burner operates but there is no combustion because - ANSWER-There is too much air 
 
On a replacement steam boiler installation, you should pipe full-size risers to the header. True or false - ANSWER-False 
 
What is the best way to remove surface oil? - ANSWER-Skimming 
 
Where should the water...
Preview 2 out of 15 pages
Add to cartThe burner operates but there is no combustion because - ANSWER-There is too much air 
 
On a replacement steam boiler installation, you should pipe full-size risers to the header. True or false - ANSWER-False 
 
What is the best way to remove surface oil? - ANSWER-Skimming 
 
Where should the water...
List three things needed for ignition? - ANSWER-Fuel, air and spark. 
 
Flame Retention Burners have what advantage over Non Flame Retention? - ANSWER-Better air to oil mixture and cleaner burning. 
 
Flame Retention Burners work on _ pressure? - ANSWER-High Static pressure. 
 
Why is it important t...
Preview 2 out of 5 pages
Add to cartList three things needed for ignition? - ANSWER-Fuel, air and spark. 
 
Flame Retention Burners have what advantage over Non Flame Retention? - ANSWER-Better air to oil mixture and cleaner burning. 
 
Flame Retention Burners work on _ pressure? - ANSWER-High Static pressure. 
 
Why is it important t...
Viscosity problems can be corrected by: - ANSWER-Decreasing the nozzle size and increasing the pump pressure accordingly 
 
The minimum operating pressure of an oil pump is: - ANSWER-100 PSI 
 
If a stack relay fails you, must? - ANSWER-Replace it with an approved type controller 
 
Aquastats are no...
Preview 2 out of 5 pages
Add to cartViscosity problems can be corrected by: - ANSWER-Decreasing the nozzle size and increasing the pump pressure accordingly 
 
The minimum operating pressure of an oil pump is: - ANSWER-100 PSI 
 
If a stack relay fails you, must? - ANSWER-Replace it with an approved type controller 
 
Aquastats are no...
coupling - ANSWER-the connection between the fuel pump and oil burner motor 
 
housing - ANSWER-encases the burner and all of its components in the heating unit 
 
fuel line - ANSWER-a line meant for the passing of fuel from the fuel pump to the burner 
 
nozzle - ANSWER-oil is forced through the no...
Preview 1 out of 1 pages
Add to cartcoupling - ANSWER-the connection between the fuel pump and oil burner motor 
 
housing - ANSWER-encases the burner and all of its components in the heating unit 
 
fuel line - ANSWER-a line meant for the passing of fuel from the fuel pump to the burner 
 
nozzle - ANSWER-oil is forced through the no...
Minimum net stack temperature of above 350°F must be maintained - ANSWER-To avoid condensation and maintain draft 
 
The primary control must be capable of reacting to - ANSWER-The presence or absence of flame 
 
The two principal combustible elements in number two fuel oil are nitrogen and carbon ...
Preview 2 out of 7 pages
Add to cartMinimum net stack temperature of above 350°F must be maintained - ANSWER-To avoid condensation and maintain draft 
 
The primary control must be capable of reacting to - ANSWER-The presence or absence of flame 
 
The two principal combustible elements in number two fuel oil are nitrogen and carbon ...
wax crystals form, gels up and the viscosity of the oil goes up - ANSWER-What happens to fuel oil when it is stored outside on a day when the temp. is only 12 degrees F? 
 
85% carbon, 15% nitrogen, (ASTM D-396) - ANSWER-What is the chemical composition of fuel oil? 
 
If flames hit chamber it will ...
Preview 1 out of 4 pages
Add to cartwax crystals form, gels up and the viscosity of the oil goes up - ANSWER-What happens to fuel oil when it is stored outside on a day when the temp. is only 12 degrees F? 
 
85% carbon, 15% nitrogen, (ASTM D-396) - ANSWER-What is the chemical composition of fuel oil? 
 
If flames hit chamber it will ...
To wire an oil burner in MA you must be a licensed electrician: T or F - ANSWER-False 
 
Flash Point is the lowest temp. at which the vapours above the fuel will ignite: T or F - ANSWER-True 
 
Pour Point is the lowest temperature at which No. 2 fuel oil can be lit: T or F - ANSWER-False 
 
If the c...
Preview 1 out of 4 pages
Add to cartTo wire an oil burner in MA you must be a licensed electrician: T or F - ANSWER-False 
 
Flash Point is the lowest temp. at which the vapours above the fuel will ignite: T or F - ANSWER-True 
 
Pour Point is the lowest temperature at which No. 2 fuel oil can be lit: T or F - ANSWER-False 
 
If the c...
Add an oil line heater. 
 
Cut with #1 fuel or kerosene. 
 
What is the maximum tank size allowed inside unenclosed? - ANSWER-660 gal 
 
What is the purpose of a delayed oil valve? - ANSWER-Allows time for the oil pump to get up to speed. 
 
Delays oil flow to the nozzle. 
 
On a call where a hydr...
Preview 3 out of 26 pages
Add to cartAdd an oil line heater. 
 
Cut with #1 fuel or kerosene. 
 
What is the maximum tank size allowed inside unenclosed? - ANSWER-660 gal 
 
What is the purpose of a delayed oil valve? - ANSWER-Allows time for the oil pump to get up to speed. 
 
Delays oil flow to the nozzle. 
 
On a call where a hydr...
The primary control starts burner operation in response to a signal from​ the_____. - ANSWER-room thermostat 
 
When replacing an oil burner​ nozzle, always use​ a(n)_____. - ANSWER-nozzle wrench 
 
When doing a smoke spot test on a heavy​ boiler, an acceptable smoke spot number​ is_____. ...
Preview 1 out of 1 pages
Add to cartThe primary control starts burner operation in response to a signal from​ the_____. - ANSWER-room thermostat 
 
When replacing an oil burner​ nozzle, always use​ a(n)_____. - ANSWER-nozzle wrench 
 
When doing a smoke spot test on a heavy​ boiler, an acceptable smoke spot number​ is_____. ...
When applying current through a conductor that is wound in coil, the magnetic lines of force created are used in - ANSWER-•Solenoid valve 
. Relay 
.Electric Motor 
 
If in an average 15-amp residential heating circuit, the fuse occasionally blows, you should - ANSWER-Install a 15-amp breaker 
 
T...
Preview 3 out of 20 pages
Add to cartWhen applying current through a conductor that is wound in coil, the magnetic lines of force created are used in - ANSWER-•Solenoid valve 
. Relay 
.Electric Motor 
 
If in an average 15-amp residential heating circuit, the fuse occasionally blows, you should - ANSWER-Install a 15-amp breaker 
 
T...
Pour point - ANSWER-The maximum temperature at which oil can be stored, retrieved and used 
 
Complete Combustion flames - ANSWER-mainly yellow 
 
Incomplete combustion flame - ANSWER-dull reddish orange 
 
The Range of CO2 content indicating proper combustion in an oil fired furnace - ANSWER-8% to ...
Preview 2 out of 5 pages
Add to cartPour point - ANSWER-The maximum temperature at which oil can be stored, retrieved and used 
 
Complete Combustion flames - ANSWER-mainly yellow 
 
Incomplete combustion flame - ANSWER-dull reddish orange 
 
The Range of CO2 content indicating proper combustion in an oil fired furnace - ANSWER-8% to ...
the breaking up of a liquid into tiny droplets - ANSWER-atomization 
 
the ignition of a large amount of vaporized fuel oil that blows soot backward out of the combustion chamber - ANSWER-blowback 
 
a pump used to move fuel oil from the main storage tank to a fuel oil accumulator or reservoir tank ...
Preview 2 out of 5 pages
Add to cartthe breaking up of a liquid into tiny droplets - ANSWER-atomization 
 
the ignition of a large amount of vaporized fuel oil that blows soot backward out of the combustion chamber - ANSWER-blowback 
 
a pump used to move fuel oil from the main storage tank to a fuel oil accumulator or reservoir tank ...
When nozzles problems are apparent, the nozzle should be removed using ____ and replaced - ANSWER-a special nozzle wrench 
 
The cad cell relay is a safety device that uses which of the following to prove ignition? - ANSWER-light in the combustion chamber 
 
The stack switch or stack relay _____. - ...
Preview 1 out of 4 pages
Add to cartWhen nozzles problems are apparent, the nozzle should be removed using ____ and replaced - ANSWER-a special nozzle wrench 
 
The cad cell relay is a safety device that uses which of the following to prove ignition? - ANSWER-light in the combustion chamber 
 
The stack switch or stack relay _____. - ...
air bend - ANSWER-regulates the volume (amount) by changing it to a spray of tiny droplets 
 
atomizing - ANSWER-vaporizing liquid oil (turning it into gas) by changing it to a spray of tiny droplets 
 
bleeder - ANSWER-on the side of the oil pump - used to remove air from oil line 
 
cad cell - ANS...
Preview 1 out of 2 pages
Add to cartair bend - ANSWER-regulates the volume (amount) by changing it to a spray of tiny droplets 
 
atomizing - ANSWER-vaporizing liquid oil (turning it into gas) by changing it to a spray of tiny droplets 
 
bleeder - ANSWER-on the side of the oil pump - used to remove air from oil line 
 
cad cell - ANS...
Ch 1 Flame Retention Burner - ANSWER-An oil burner, designed to hold the flame near the nozzle surface. Strongly swirling air pattern recirculates combustion products for more complete mixing of fuel and air. 
 
Ch 1 Motor - ANSWER-Electric motor drives the fan and fuel pump. In the event of motor f...
Preview 1 out of 2 pages
Add to cartCh 1 Flame Retention Burner - ANSWER-An oil burner, designed to hold the flame near the nozzle surface. Strongly swirling air pattern recirculates combustion products for more complete mixing of fuel and air. 
 
Ch 1 Motor - ANSWER-Electric motor drives the fan and fuel pump. In the event of motor f...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Topgrades20. Stuvia facilitates payment to the seller.
No, you only buy these notes for £18.79. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
75057 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now