ACI Concrete Field Testing Technician - Grade 1 (18) Exam Questions with correct Answers ASTM C1064 - Answer- Standard Test Method For Temperature of Freshly Mixed Hydraulic-Cement Concrete
The end of the temperature sensing portion of the temperature measuring device shall be submerged a minimum of ____ into the freshly mixed concrete. - Answer- 3 inches [75 mm] C1064, Sec. 8.1
The temperature measuring device shall have a capacity of measuring the temperature of freshly mixed concrete to ± ____ °F (± ____ °C) throughout a range of ____ °F ( ____
°C). - Answer- ±1 °F (±0.5 °C) ; 30 to 120 °F (0 to 50 °C) C1064, Sec. 5.2
The temperature measuring device shall be calibrated ____ , or whenever there is a question of ____ . - Answer- annually, accuracy
C1064, Sec. 6.1
The temperature of concrete may be measured in a wheelbarrow. True or False - Answer- True
The temperature of concrete may be measured in a wall form. True or False - Answer- True
C1064, Sec. 7.1
A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temperature. True or False - Answer- False
C1064, Sec. 7.2.2
What must be done to the sample container prior to sampling the concrete? - Answer- Dampen with water
C1064, Sec. 7.2.1 What must be done to the concrete surrounding the temperature measuring device after
the device is submerged in the fresh concrete? - Answer- Close off air voids by gently pressing the concrete around the device
C1064, Sec. 8.1
How long must the temperature measuring device remain in the freshly mixed concrete?
- Answer- minimum of two minutes, maximum of five minutes
C1064, Sec. 8.2
After the temperature of the concrete is read, what is then required? - Answer- Reporting of temperature
C1064, Sec. 9.1
The temperature of the concrete is reported to the nearest ____ °F - Answer- 1 °F (0.5 °C)
C1064, Sec. 9.1
According to Test Method C1064, what is one reason to take the temperature of concrete? - Answer- Verify conformance to a specified requirement for temperature of concrete
C1064, Sec. 4.1
A maximum temperature of freshly mixed concrete is specified in ASTM C1064. True or False - Answer- False
The sample of concrete used for temperature determination must be rodded 25 times. True or False - Answer- False
C1064, Sec. 7 & 8
ASTM C172 - Answer- Standard Practice for Sampling Freshly Mixed Concrete
Sampling by this practice covers procedures for obtaining representative samples, on which tests are to be performed to determine ____ with quality requirements of the specifications under which the concrete is furnished. - Answer- compliance C172, Sec. 1.1
This practice covers sampling from five types of equipment, which are ____, ____, ____, ____, and ____. - Answer- stationary mixers, paving mixers, revolving drum mixers, continuous mixers, and open top mixers C172, Sec. 5.2.1 - 5.2.4
The maximum allowable time between obtaining the first and final portions of a composite sample shall not exceed ____ . - Answer- 15 minutes
C172, Sec. 4.1
Portions of a composite sample shall be thoroughly remixed before beginning tests on the sample. True or False? - Answer- True
C172, Sec. 4.1.1
Start tests for slump, temperature, and air content within ____ after obtaining the final portion of the composite sample? - Answer- 5 minutes
C172, Sec. 4.1.2
The maximum elapsed time allowed between obtaining the final portion of the composite sample and beginning the tests for slump, temperature, and air content is ____ minutes. - Answer- 5 minutes
C172, Sec. 4.1.2
Start molding specimens for strength tests within ____ after fabricating the composite sample. - Answer- 15 minutes C172, Sec. 4.1.2
The concrete sample must be protected from contamination and ____ . - Answer- rapid evaporation
C172, Sec. 4.1.2
The minimum size sample for making strength test specimens is ____ . - Answer- 1 ft³ [28 L]
C172, Sec. 5.1
When sampling from a stationary mixer, the batch must be sampled at ____ or more regularly spaced intervals during discharge of the middle portion of the batch. - Answer- two
C172, Sec. 5.2.1

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller millyphilip. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for £11.13. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76449 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now

Start selling
£11.13
  • (0)
  Add to cart