If a generator is producing 500MW and 200Mvar, the generator is:
✔️Ans -Lagging

87 ✔️Ans -Is the IEEE device number for a differential relay.

Can a Synchronous machine have a negative torque angle? What doies this
mean? ✔️Ans -Yes, the machine is absorbing active power.

A customer load is fed at 12o Volts. The customer's voltage is doubled while
the load magnitude stays the same. What effect does this have on the power
losses? ✔️Ans -Decreases the losses by a factor of 4.

In a DC circuit, a 100V battery is connected to both sides of a 2 ohm resistor.
What is the current through the resister and the power usage of the resister?
✔️Ans -50A/5000W

Which of the following is not a synchronizong variable? ✔️Ans -
MW flow differential.

In a typical multi-stage steam turbine, the governor control valves control
steam entry into the: ✔️Ans -High pressure turbine

The high side of a delta-wye connected transformer is connected to a power
system with 199KV L-G high side voltage. What is the voltage across the
winding of the delta transformer? ✔️Ans -345KV

Thermal limits are the direct result of? ✔️Ans -The thermal
capability of system equipment.

Reactive power flow is influenced more by system power and torque angles
than reactive power. True or False ✔️Ans -False

At what line power angle does the MW transfer across a transmission path
equal 1/2 of the path's Pmax? ✔️Ans -30 degrees

, A transmission line is rated at 1000MVA. The power flow on the line is 0MW
and 1001Mvar. Is the transmission line overloaded? ✔️Ans -Yes

The TTC limit has been determined to be 1000MW from east to west for a
particular transmission path. The transmission path operator sells 500MW of
its TTC. What is the path's ATC? ✔️Ans -500MW

A distribution line is rated for 50MVA. The line's power flow is currently
50MW and -50Mvar. The line is overloaded. True or Flase ✔️Ans -
True

Angle instability is the result of: ✔️Ans -High torque and power
angles.

If the resistance is ignored, the maximum theoretical MW flow across a
transmission line will occur at a power angle of: ✔️Ans -90
degrees.

If the resistance is ignored, the maximum theoretical Mvar flow across a line
will occur at a power angle of: ✔️Ans -180 degrees

200MW is schediuled to flow from bus X to bus Y. Transmission line A-B has a
distribution factor of 10% for this schedule. How many MW will flow on
transmission line A-B? ✔️Ans -20MW

According to the load/frequency relationship, a 1% change in frequency will
lead to what approximate magnitude of load change in a typical 10000MW
system? ✔️Ans -200MW

A governor with a 0% droop is called: ✔️Ans -An isochronous
governor

Steam turbine generators typically have better governor response than
hydroelectric generating units. True or False ✔️Ans -False

A balancing authority's frequency bias is equal to: ✔️Ans -The
balancing authority's frequency response characteristic (FRC), the natural
response of the BA, The AGC system's bias value.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Studycafe. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for £8.57. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79223 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now

Start selling
£8.57
  • (0)
  Add to cart