100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
CETP 4.5 Basic Propane Appliance Service and Troubleshooting Questions with 100% Actual correct answers | verified | latest update | Graded A+ | Already Passed | Complete Solution £6.46   Add to cart

Exam (elaborations)

CETP 4.5 Basic Propane Appliance Service and Troubleshooting Questions with 100% Actual correct answers | verified | latest update | Graded A+ | Already Passed | Complete Solution

 6 views  0 purchase

CETP 4.5 Basic Propane Appliance Service and Troubleshooting Questions with 100% Actual correct answers | verified | latest update | Graded A+ | Already Passed | Complete Solution

Preview 3 out of 17  pages

  • June 19, 2024
  • 17
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
All documents for this subject (376)
avatar-seller
Hkane
CETP 4.5 Basic Propane Appliance
Service and Troubleshooting

________ can be formed into a number of shapes; straight, U-shaped, disc shaped,
and coiled. - correct answer-Bimetals




_________ are two pieces of metal known to expand at different rates when heated.
________ sense temperature change and either open or close a switch. - correct
answer-Bimetals




___________ switches sense the flow of air. The __________ is a type of ________
switch that can be used on propane appliances. - correct answer-Air flow, sail switch,
air flow




____________ are designed for general purpose measurement of air, surface, and
gases. Extremely fast response time because of a small exposed tip. - correct
answer-Bead Probes




_______________ are safety devices. - correct answer-High limit controls




_______________ sensors are used on storage water heaters to sense the
temperature of water inside a water heater activate a switch that allows gas to flow to
the burner to heat water. - correct answer-Rod and tube




________________ were developed for unvented room heaters. - correct
answer-Oxygen Depletion Sensor (ODS)

,__________________ gas valves are used with some older mobile home furnaces. -
correct answer-slow opening




_____________________ should be tested for proper operation as apart of
preventative maintenance. - correct answer-Safety shutoff devices




A ________ used as a safety switch generally is normally closed (NC) and opens on
a temperature rise. - correct answer-bimetal




A ____________ is used only for a short time to give little extra power to start a
motor. Any _________ over 70 microfarads is a ____________ . - correct
answer-start capacitor, capacitor, start capacitor




A ____________ operates for the entire cycle of the motor operation. - correct
answer-run capacitor




A _______________ gas control valve is similar to a standard opening gas control
valve for other operators. - correct answer-snap-action




A 24-volt operator is commonly used for appliances such as ________ and
_________ that have standing pilot or electronic ignition systems. - correct
answer-furnaces, boilers




A bimetal sensor rated L140-40F is operating correctly if the switch opens at 120
degrees, T/F? - correct answer-False

, A Combustible Gas Indicator (CGI) can also signal an alarm when the level of gas
concentration in the air reaches/exceeds preset points marking the flammability
range. These presets points are called ____ or ____ for ____________ or
____________. - correct answer-LEL, LFL, Lower Explosive Limit, Lower
Flammability Limit




A common cause of no heat service calls is that a ________________ has opened. -
correct answer-limit switch




A gas control valve should be replaced if it is difficult to turn by hand, T/F? - correct
answer-True




A thermopile is energized when the _________ surrounds the tip of the thermopile.
The thermopile provides the power to operate the ______________ through the
thermostat circuit. - correct answer-pilot flame, gas control valve




All electrodes will spark at a rate of approximately ___________ per second. -
correct answer-2 1/2 pulses (sparks)




Almost 120 volts are used to power the igniter. Generally only
___________________ are required to operate the gas valve, depending on the
type of valve and igniter. - correct answer-3 volts (and 3.2 to 3.5 amps)




As propane vapor passes through orifice to the burner, it mixes with
_________________ . - correct answer-primary air

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Hkane. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for £6.46. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

62890 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now

Start selling
£6.46
  • (0)
  Add to cart