100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Oil burner test Questions with 100% Actual correct answers | verified | latest update | Graded A+ | Already Passed | Complete Solution £6.49   Add to cart

Exam (elaborations)

Oil burner test Questions with 100% Actual correct answers | verified | latest update | Graded A+ | Already Passed | Complete Solution

 4 views  0 purchase

Oil burner test Questions with 100% Actual correct answers | verified | latest update | Graded A+ | Already Passed | Complete Solution

Preview 2 out of 5  pages

  • June 19, 2024
  • 5
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
All documents for this subject (414)
avatar-seller
Hkane
Oil burner test
A chimney connector shall not pass through a - correct answer-Floor or cieling

A venting system that terminates in the sidewall shall be - correct answer-3 feet above any
air inlet that is within 10 feet of the vent.

Are probe type or float type low-water cutoff switches acceptable? - correct answer-Yes, as
long as they are of a listed types and used per the appliance manufacturers instructions.

Can a Certified Oil Burner Technician wire a new oilburner? - correct answer-No, only a
licensed electrician can wire a new installation. However, wiring of replacement equipment
may be done by a certified technician within the guidelines of the Advisory Ruling of the
Board of Electricians dated December 3, 1993.

Can a technician replace an existing primary control with a safety timing of more than 15
seconds during a routine service call? - correct answer-Yes, but only to replace an existing
control of the same type already is use and existing. Any new primary control being installed
must have a safety timing of no longer than 15 seconds and be equipped to provide for
interrupted ignition.

Can any power venter be used? - correct answer-Yes, as long as the power venter is listed,
used within its listing, and installed according to the manufacturer's instructions.

Can anyone make out Form 1 or Form 1A? - correct answer-Yes, but only a holder of a
Certificate of Competency can sign as the installer on a Form 1 and as the inspector in the
case of a Form 1A.

Can I cross connect two tanks (at the bottom) to the same burner with 3/8 inch pipe or
tubing? - correct answer-No, the cross connection of two supply tanks to the same burner
must be made with pipe no smaller than 1/2 inch iron pipe or 1/2 o.d. tubing.

Can I place an oilfired unit up against a wall? - correct answer-Cleanout and service Yes, as
long as it was constructed for zero clearance from combustibles. panels may not be blocked,
and clearances must be verified using manufacturer's literature.

Can I put an oil tank under a stairway? - correct answer-Yes, nothing in NFPA 1 prohibits the
installation of an oil tank under a stairway unless it blocks means of egress, or blocks service
meters, valves, or panels.

Can I still use an old "Mass. 'approved' tank"? - correct answer-No. After May 1, 1996 only
tanks that are constructed to the UL Standards found in NFPA 1 are acceptable.

Can I use a stack switch? - correct answer-Only to replace an existing control of the same
type already in use and existing.

, Can I use any forms other than Form 1 or Form 1A? - correct answer-No, only Form 1 and
form 1A as approved by the State Fire Marshal shall be used by local fire departments and
installers. No modification whatsoever of the form are allowed.

Can I use either the button type or wheel type thermal (Firomatic) switch? - correct
answer-Yes, any thermal switch may be used as long as the manufacturer has secured a
listing from an approved testing lab, and that the switch complies with both CMR 1.00, and
the Massachusetts Electrical Code,

Can I use Teflon tape when piping oil lines? - correct answer-No.

Can you solder an oil line? - correct answer-Yes, by brazing using traditional solder with a
melting point of over 500°F.

Chimney connector need a pitch of - correct answer-1/4

Chimney connector of low, medium, or high heat Industrial appliance shall not pass through
a - correct answer-Combustible wall of partisan

Crankcase/used oil may only be used in - correct answer-Commercial/industrial setting. Or in
a appliance specifically designed to do so.

Do I have to sheetrock or install a sprinkler if I have combustibles within five feet vertically of
the heating unit? Is an AFUE or EF Listing required? - correct answer-No, the so called
"overhead protection" requirement is no longer required after January 1, 2015.

Do I need to pull a permit when replacing an oil line or installing an osv? - correct
answer-Yes. Any alteration of an oil burner installation requires a permit be pull under CMR
1.00 using a Form 1 only.

Draft is created by - correct answer-Pressure difference between top and bottom of the
chimney

Draft produced by a chimney is - correct answer-Variable

Excessive draft drop through the heat exchanger indicates - correct answer-Heavy soot and
scale deposits in the heat exchanger

Flue gas exit of a chimney shall be Atleast - correct answer-3 feet above highest point of the
building, 2 feet above any portion of a building within 10 feet

Flue pipe must be how far from combustible wall - correct answer-18 inches

Flue pipe should not exceed __ without a draft fan - correct answer-10 feet

High draft will cause - correct answer-Too much air and reduced efficiency

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Hkane. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for £6.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79373 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now

Start selling
£6.49
  • (0)
  Add to cart