BACKFLOW PREVENTION FINAL EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 1. Backflow is defined as: a) the pressure in the distribution piping of the potable water supply b) the undesirable reversal of water, other liquids, gases or substances in the distribution pipes of the potabl...

[Show more]

Preview 4 out of 43  pages

  • June 30, 2024
  • 43
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
BACKFLOW PREVENTION FINAL EXAM QUESTIONS WITH

COMPLETE SOLUTIONS VERIFIED GRADED A+


1. Backflow is defined as:

a) the pressure in the distribution piping of the potable water supply

b) the undesirable reversal of water, other liquids, gases or substances in the

distribution pipes of the potable water supply

c) high pressure in the pipes of the water user

d) excess pressure through a pressure regulator

b) the undesirable reversal of water, other liquids, gases or substances in the

distribution pipes of the potable water supply

2. Primary responsibility for cross connection control is vested in

a) the water purveyor

b) the water site supervisor

c) the health department

d) the State Health department

a) the water purveyor

3. A reduced pressure principle backflow prevention assembly is comprised of:

a) two independently operating air inlet valves with a hydraulically operating

mechanically independent differential relief valve

b) two check valves, two shut off valves and an air relief valve

c) two independently acting approved check valves, a hydraulically operated

,differential pressure relief valve, with four appropriately located resilient seated

test cocks and two resilient seated shut off valves

d) two independently operated approved check valves, mechanically operated air

relief valve, four resilient seated test cocks between two resilient seated shut off

valves

c) two independently acting approved check valves, a hydraulically operated differential

pressure relief valve, with four appropriately located resilient seated test cocks and two

resilient seated shut off valves

4. A local ordinance establishing a cross connection control program must

require that:

a) the property owner test the assembly periodically

b) a certified tester test the assembly at least once every twelve months and

report the test results to the water purveyor it a timely manner

c) the water purveyor will install the necessary cross connection control

assembly

d) pressure vacuum breaker will be installed at all service connections

b) a certified tester test the assembly at least once every twelve months and report the

test results to the water purveyor it a timely manner

5. The definition of an approved air gap used for backflow prevention shall be:

a) be equipped with a splash guard and a receiving funnel

b) be not less than one inch from the side wall of the receiving vessel

c) be a vertical dimension of at least twice the diameter of the supply pipe but not

,less than one inch above the receiving vessel

d) be less that one inch above the flood rim of the receiving vessel

c) be a vertical dimension of at least twice the diameter of the supply pipe but not less

than one inch above the receiving vessel

6. The correct installation of a reduced pressure principle backflow prevention

assembly is:

a) it doesn't matter where the assembly is placed

b) in a pit behind the water meter

c) in a vented vault below the floodplain

d) in an above grade, protected and accessible site

d) in an above grade, protected and accessible site

7. If water is continuously flowing from the relief valve port of a reduced pressure

principle backflow prevention assembly the tester may report:

a) the relief valve is stuck closed

b) the first check may be fouled, or the differential pressure relief valve may have

malfunctioned, or the second check is fouled with backpressure on the assembly

c) the distribution line is subject to pressure surges

d) the number two check valve has failed

b) the first check may be fouled, or the differential pressure relief valve may have

malfunctioned, or the second check is fouled with backpressure on the assembly

8. Backpressure will cause backflow:

a) through an unprotected over the rim feed to an open make-up water tank

b) through an unprotected over the rim gravity feed line to an open wash tank

, c) through an unprotected feed to a closed make-up water tank

d) through an unprotected feed to a cattle watering trough

c) through an unprotected feed to a closed make-up water tank

9. In testing a reduced pressure principle backflow prevention assembly:

a) the relief valve must be tested first

b) the apparent drop across the first check valve must be tested first

c) the second check must be tested first

d) the flow rate must be tested first

a) the relief valve must be tested first

10. A water purveyor or public health agency may require more frequent testing

of a backflow prevention assembly than the maximum time allowed between

testing. What is the maximum legal length of time permitted between tests:

a) six months

b) eighteen months

c) twelve weeks

d) twelve months

d) twelve months

11. Which of the following types of cross connections are considered to be

illegal?

a) a by-pass hose with a shut off valve installed around a reduced pressure

principle backflow prevention assembly

b) a supply line to a boiler from a domestic service equipped with a reduced

pressure principle backflow prevention assembly

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller AcademicSuperScores. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for £8.56. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75632 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now

Start selling
£8.56
  • (0)
  Add to cart