Which standard establishes limits for the VOC content of furniture for Feature 04 VOC Reduction? - ANSWERSThe ANSI/BIFMA e3-2011 Furniture Sustainability Standard establishes limits for VOC content for furniture and furnishings in Feature 04 ...
well ap test 2024 questions with complete solution
Written for
WELL AP
WELL AP
Seller
Follow
Bensuda
Reviews received
Content preview
WELL AP Test 2024 Questions with
complete Solutions
Which standard establishes limits for the VOC content of furniture for Feature 04 VOC Reduction? -
ANSWERSThe ANSI/BIFMA e3-2011 Furniture Sustainability Standard establishes limits for VOC content
for furniture and furnishings in Feature 04 VOC Reduction.
In order to comply with Feature 26 Enhanced Material Safety, 25% of products (by cost) must be certified
under which standard? - ANSWERSCradle to Cradle
Exceeding ASHRAE minimum fresh air supply rates by what amount is the requirement for earning
Feature 15 Increased Ventilation? - ANSWERS30% ????
A restaurant is upgrading their HVAC system, and is concerned with the negative effects that humidity
extremes can have on the building occupants. What can they do to ensure that humidity levels will be in
the acceptable range? - ANSWERSUse modeling software to show that humidity levels will be within the
acceptable range for 95% of all annual business hours.
A janitorial company is beginning work at a WELL-Certified building, and several requirements related to
the WELL Building Standard are written into the contract. Since the project has achieved Feature 29,
which of the following requirements must all cleaning equipment meet? - ANSWERSCleaning products
are certified by EPA's Design for the Environment, UL EcoLogo, or Green Seal.
What is the primary reason to introduce activated charcoal filters to the main air ducts of an existing
building? - ANSWERSTo reduce VOCs in the indoor air.
The Property Manager for a Johannesburg office building is installing lobby signage to display real-time
data on indoor environmental quality. What is NOT a required parameter for this display to meet the
requirements of Feature 18 Air Quality Monitoring and Feedback? - ANSWERSCarbon monoxide
Real-time display of temperature, humidity, and carbon dioxide concentration must be made available to
achieve Part 03 of Feature 8 Air Quality Monitoring and Feedback.
, Which WELL Features requires that all doorknobs be coated in or comprised of a material that is
abrasion-resistant, non-leaching and meets EPA testing requirements for antimicrobial activity? -
ANSWERSFeature 27 Antimicrobial Activity for Surfaces
What is the humidity level required to meet Feature 16 Humidity Control? - ANSWERSBetween 30% and
50%
In cleaning storage areas, which two items should be stored in separate bins from one another? -
ANSWERSBleach and ammonia-based products
Which WELL Features promotes the use of products that have been independently verified to be free of
many suspected hazards? - ANSWERSFeature 26 Enhanced Material Safety
A new medical office building is being constructed in a suburban campus setting. The 2-story building is
planned to hold 6 tenants, and the main lobby will host a 24-hour security desk and a daily parking
attendant. The building architect did not specify revolving doors for the building entry system; however,
a tenant intending to move into the 2nd floor of the new building would like to pursue WELL
certification. Which of the following would qualify as an air seal for Feature 08 Healthy Entrance? -
ANSWERSAn entryway vestibule with 2 sets of normally-closed doors (because this building will have a
regularly occupied lobby).
A retailer is designing a new corporate office for the global headquarters. The architect is preparing
narratives for the WELL Feature 12 Moisture Management. In addition to the narratives that describe
how exterior and interior water from common sources are addressed, what other narrative should the
architect prepare? - ANSWERSCondensation, and materials selection and protection
A London office building's air quality test has met 3 of the minimum requirements for particulate matter
and inorganic gases: Carbon monoxide, PM2.5, and PM10. What other minimum standard is required for
WELL Certification? - ANSWERSOzone less than 51 ppb
Feature 01 Air Quality Standards, Part 2 has 4 required thresholds:
1. Carbon monoxide less than 9 ppm; 2. PM2.5 less than 15 µg/m3; 3. PM10 less than 50 µg/m3; 4.
Ozone less than 51 ppb
The new Property Management team at a Toronto building would like to implement a pesticide
management policy and pursue WELL certification. Where should they look for a list of acceptable
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Bensuda. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for £6.77. You're not tied to anything after your purchase.