WELL AP Review Exam Questions & Answers 2024/2025
Requirements for Uniform Color Transmittance are included with which WELL Feature? - ANSWERSFeature 63 Daylighting Fenestration
What is the acceptable Light Reflectance Values (LRV) for ceilings? - ANSWERS0.8 - 0.9
.8 (80%) or more for at l...
Requirements for Uniform Color Transmittance are included with which WELL Feature? -
ANSWERSFeature 63 Daylighting Fenestration
What is the acceptable Light Reflectance Values (LRV) for ceilings? - ANSWERS0.8 - 0.9
.8 (80%) or more for at least 80% of surface area in spaces occupied regularly.
What term refers to minimum levels of natural lighting in spaces? - ANSWERSSpatial Daylight Autonomy:
Specifically, it describes the percentage of floor area that receives at least 300 lux for at least 50% of the
annual occupied hours.
Annual sunlight exposure places a cap on inappropriately high levels of sunlight.
Which of the following is NOT a benefit of automated controls for shading devices:
Ensures the systems operate as intended
Helps regulate circadian cycle
Contributes to energy use reduction
Contributes to comfort without disrupting occupants from other tasks - ANSWERSHelps regulate
circadian cycle
The circadian rhythm is an internal clock in humans and animals that synchronize physiological functions
on a cycle of what duration? - ANSWERS24 hours
On buildings with greater than 40% window-to-wall ratio as measured from exterior elevations, what
control measure is required to earn Feature 63 Daylighting Fenestration? - ANSWERSExternal Shading or
Adjustable Opacity Glazing
, In an existing retail center under renovation and pursuing WELL Certification, 50% of the windows are
being replaced. The project team is tasked with reducing glare in the building. Where is the most
appropriate location for a film of micro-mirrors on the window? - ANSWERSGlazing over 7ft AFF.
In order to minimize glare at workstations and desks, bare lamps and luminaire surfaces more than 53
degrees above the center of view must have luminances of what intensity? - ANSWERSLess than 8,000
cd/m2 per Feature 55 Electric Light Glare Control
What specific part of the body acts as a main internal clock that synchronizes with clocks in peripheral
tissues and organs? - ANSWERSSuprachiasmatic nucleus
Which Feature addresses the maximum luminance allowed for light fixtures above 53 degrees above the
center of view? - ANSWERSFeature 55 Electric Light Glare Control
A new university dorm is being constructed in Rome. The project team is pursuing Feature 60 Automated
Shading and Dimming Controls. Which windows need to have shading devices that automatically engage
when light sensors indicate that sunlight could contribute to glare at workstations? - ANSWERSAll
windows larger than 6 ft 2 [.55m2]
In an office building new construction project, consideration of the brightness contrast between which
two areas is NOT required? - ANSWERSMain lobby and the exterior
What is the ideal lighting type for building occupants? - ANSWERSDiffuse daylight
An average intensity for ambient lighting systems is 215 lux (20fc) and is required in what types of areas?
- ANSWERSWorkstations and desk areas
Feature 53 Visual Lighting Design, Part 1 Visual Acuity for Focus, refers to light level requirements at
workstations or desks. In these areas, ambient lighting must be able to maintain an average light
intensity of 215 lux (20 fc) or greater.
What is the name for the external cues that align physiological functions to the solar day? -
ANSWERSZeitgebers: a cue given by the environment, such as a change in light or temperature, to reset
the internal body clock
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Bensuda. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for £6.77. You're not tied to anything after your purchase.