Traditional Mills correct answers -Iron ore is processed into molten iron in a blast furnace, then converted to steel
- 25%-35% recycled
- Primary products: flat-rolled stock such as steel decking and other sheet products
Mini-Mills correct answers - Most US steel is made from recycled steel s...
COSC 253 Exam 3 Simms || A Verified A+ Pass.
Traditional Mills correct answers -Iron ore is processed into molten iron in a blast furnace, then
converted to steel
- 25%-35% recycled
- Primary products: flat-rolled stock such as steel decking and other sheet products
Mini-Mills correct answers - Most US steel is made from recycled steel scrap here
- steel scrap is converted directly to new steel using electric arc furnaces
Pros: less expensive to build, high quality low cost, use less energy, 90%+ recycled content, in
North America, almost all hot-rolled structural steel shapes are made from recycled steel here
Wide Flange correct answers - W shape
- most commonly used shape in beams and columns
- greater web depth for longer span
Wide-Flange Shape Designation correct answers "W10 x 30"
- W = wide flange shape
- 10 = nominal depth in inches
- 30 = Weight in pounds per lineal foot
- by varying roller size and spacing, various weights can be produced, all nominally 10" in depth
Channels, Tees, Angles correct answers For trusses, lighter weight framing, and other
miscellaneous uses
WT: T-shape cut from a W-shape correct answers "WT 13.5x47"
- 13.5"depth of web x 47 lb/ft
- Produced by cutting a W27x94 lengthwise in half
L angles correct answers "L4x3x3/8"
- 4" x 3" nominal legs
- with 3/8" thickness
HSS (Hollow Structural Section) correct answers "HSS 8x8x1/2"
- 8"x8"x1/2" wall thickness
- hollow square, rectangular, round, and elliptical shapes
- cold or hot-forming steel strip (sheet) and welding longitudinally
- suitable for structural members subject to twisting or buckling stresses
- used for trusses, structural column sections, and where simple external profile is desirable
Cold-worked (formed) steel correct answers Deforming steel in its cold state causes realignment
of steel crystals and increases its strength
Riveting correct answers - White hot fastener is inserted through holes to be fastened
- fastener is hammered to produce a head on the plain end
- metal cools and contracts tightly clamping steel members
, -rarely used today, mostly in historic structures
Bolts correct answers Carbon steel bolts - relatively low strength, limited uses, fastening light
frame elements and holding temp connections, also called common/unfinished bolts
High strength bolts - stronger than common bolts, used for fastening primary structural members,
heat treated for tensile strength
bearing-type connection correct answers - bolts only need to be installed in a snug tight condition
- body of bolt resists movement between connected members by bearing against sides of bolt
holes
- shear stress
- connection will slip before reaching full strength
slip-critical connection correct answers - bolt is tensioned to such an extent that movement in the
joint is resisted by friction between the members themselves
- bolt is very highly stressed but in tension
- no slippage, bolts tightened to 70% of their strength
- used where joints experience load reversals, high stressed joints, or where slippage would be
detrimental (column splices in tall buildings)
Bolt Tensioning correct answers Turn-of-nut method: nut is tightened 1/3 a turn past snug
Load indicator washers: when bolt is adequately tensioned, protrusions on the water are
flattened, some indicator washers squirt dye
Calibrated wrench: torque wrench used to tighten bolts, not used frequently
shear connection correct answers - joins only the web of the beam to column flange
- transfers gravity (shear) loads from beam to column
- not sufficiently rigid to transfer bending forces (bending moment)
Moment connections correct answers -Beam flanges are joined to column
-transfers gravity (shear) loads and bending forces to column
-Column may be reinforced with stiffener plates to carry bending forces
- welds join top and bottom beam flanges to column and reinforcing plates
- creates continuous beam condition that transmits bending forces
Coped Beam to Girder Connection correct answers - steal beam to girder connection
- top flanges of beam are coped (cut away) to allow the tops of a beam and girder to be set level
Column to Column Connection correct answers - column splices typically at waist height to
avoid interference with beam-column connections
- where outer dimensions of connected columns differ, a butt plate or bearing plate is added to
the connections
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller FullyFocus. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for £9.04. You're not tied to anything after your purchase.