in a guardrail system; the guardrail can be made of any of the following except? - Answer-Rope banding What is type USE cable primarily used for? - Answer-Direct burial in the earth Electrical gloves should be inspected before each use to determine: - Answer-The maximum voltage they can stand...

[Show more]

Preview 3 out of 16  pages

  • September 4, 2024
  • 16
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • NCCER Electrical
  • NCCER Electrical
avatar-seller
NCCER Study Guide-Part 3 Exam
Questions with Correct Answers
in a guardrail system; the guardrail can be made of any of the following except? -
Answer-Rope banding

What is type USE cable primarily used for? - Answer-Direct burial in the earth

Electrical gloves should be inspected before each use to determine: - Answer-The
maximum voltage they can stand.

Which of the following is the classified location where combustible fibers are always
present? - Answer-Class 3, Division 1

As the load decreases on a squirrel cage induction motor; its power factor: - Answer-
increases

When installing 4/0 and larger cables in a cable tray; the tray width must not be less
than the sum of the cable: - Answer-Diameters

All multimeters are capable of measuring: - Answer-Current, voltage, and resistance

What is the resultant distance between center bends for a 10 - inch offset at 15
degrees? - Answer-38.7 inches

A current transformer has a rating of 4000:5. If 2000 amps loads is on the primary; the
secondary output would produce : - Answer-2.5 amps

What is the approximate developed length of a 40" radius 90° bend? - Answer-(DL =
1.57 × Radius)63"

A megohmmeter will be used to check a cable. The electrician must be sure that the
circuit is - Answer-de energized and locked, tagged out, and tested

Which of the following factors is used to control the speed of an induction motor ? -
Answer-Frequency

Electrical hand tools that use a regular 120v system must be 3 wire grounded unless
the : - Answer-Tool is double insulated and is approved by an independent testing
facility

If the potential across a circuit is 48 volts and the current is 5 amps the resistance of the
current is? - Answer-9.6 ohms

,the drawing scale is most likely to be found in which of the following drawing locations?
- Answer-the drawing title block

A UL listed rod type grounding electrode most have a minimum length of? - Answer-8"

What is the minimum number of overload sensing units required for all three phase
motor? - Answer-3

In a circuit of pure capacitance; the current leads the voltage by an angle of? - Answer-
90 degrees

The standard unit for measuring the cross-sectional area of wire is the? - Answer-
circular mil.

The length of a bare copper conductor in a ground ring must be buried no less than 2.5
" below grade and with a length of at least? - Answer-20ft

When installing heating cables for anti-icing systems; cable patterns should be in a? -
Answer-serpentine pattern

An auxiliary holding contact ( seal - in) on a NEMA starter is indicated by the terminal
marking ? - Answer-A1 & A2

The neutral bus in a sub panel is: - Answer-bonded

The peak voltage in a nominal 120/208 VAC system is : - Answer-208 V

THWN conductors have an outer jacket made of : - Answer-nylon

What is shown on a sectional drawing? - Answer-cutaway view of a building

Who is allowed to remove another electricians tag or lock from any valve;switch;or piece
of equipment without proper authorization? - Answer-no one

The main purpose of a revision block on an electrical drawing is to - Answer-Note any
changes to the original drawings

Which of the following is the classified location where combustible vapors are always
present? - Answer-Class 1 , Division 1

Exposed field-rounted electrical conduit should be installed so that it is - Answer-plumb
and level

When wiring a 3- wire control push button control circuit; the auxiliary holding contact
(seal-in) is wired with the start button in : - Answer-parallel

, Ferrous metal raceways ;boxes ; fittings; and supports must be protected against: -
Answer-corrosion

With a row of 3 -4" conduits and a second row of 3 -2" and 2 -1" conduits for an angle
pull box; what is the minimum distance between the opposite walls of the pull box ? -
Answer-32"

A conductor with 220 mils of insulation would have insulation thickness of - Answer-
0.22"

A protective device for limiting voltage spikes by discharging or bypassing surge current
is called a : - Answer-surge limiter

Which one of the fuses is a standard size according to the NEC? - Answer-3

What is the symbol for the secondary side of a transformer? - Answer-X

The most common transformer found on an industrial site is: - Answer-Single phase
step down

Applications for heat tracing systems with a self regulating control include those
requiring a narrow operating range and : - Answer-Temperature sensitive fluids

With a row of 3 -4" conduits and second row of 3 -2" and 1-1" conduits on each side for
a straight pull box what is the minimum distance between the opposite walls of the pull
box? - Answer-32"

When installing cables smaller than 4/0 in a cable tray; the allowable cable fill area must
not be less than the sum of the cable : - Answer-cross-sectional areas

The meter used to measure pulling tension is known as a : - Answer-dynamometer

On a push button; normally closed contacts are generally used to open a circuit to : -
Answer-initate a stop or off circuit function

How should heat shrink insulators be installed? - Answer-The insulator should be
slipped over the connector and heat should be applied for a few seconds

The conductor used to connect the system grounded conductor or the equipment to
grounding electrode or to a point on the grounding electrode system is called a: -
Answer-grounding electrode conductor

A material with poor electrical conducting properties is a: - Answer-good insulator

A 1000 KVA three phase transformer has a secondary voltage of 208/120. What is the
secondary full load amperage? - Answer-4817

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller lectknancy. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for £12.94. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77333 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now

Start selling
£12.94
  • (0)
  Add to cart