Ohio Sprinkler Technician Practice Test Exam Review 100% Guaranteed Pass! 1. For ESFR sprinklers, the clearance between sprin- kler and the top of the storage shall be... 36 inches 2. Permits required for the removal of a standpipe sys- tem on state property, when not issued by the loca...

[Show more]

Preview 2 out of 10  pages

  • September 5, 2024
  • 10
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
avatar-seller
Ohio Sprinkler Technician Practice Test
Exam Review 100% Guaranteed Pass!
1. For ESFR sprinklers, the clearance between sprin- 36 inches
kler and the top of the storage shall be...

2. Permits required for the removal of a standpipe sys- State fire marshal
tem on state property, when not issued by the local
fire code official, shall be obtained from...

3. Components that do not affect systems perfor- True
mance such as drain piping, drain valves, and signs
shall not be required to be listed...

4. Under certain circumstances, NFPA 13 allows the CPVC
use of "other" types of pipe or tube materials includ-
ing...

5. The minimum operating pressure of any sprinkler True
head in a residential (13D) sprinkler system shall
be the higher of the minimum operating pressure
specified by the listing or 7 PSI...

6. Equipment, materials, or services included in a list Listed
by an organization that us to the authority having
jurisdiction and concerned with evaluation of prod-
ucts or services, that maintains periodic inspection
of production of listed equipment or materials or
periodic evaluation of services, and whose listing
states the either the equipment, materials, or ser-
vices meets the appropriate designated standards
or has been tested and found suitable for a specified
purpose is a definition of...

7. Panel construction and other construction were Obstructed construc-
beams, trusses and other members impede heat tion
flow or water distribution in a in a matter that ma-
terially affects the ability of sprinklers to control or
suppress fire is know as...

8. Ordinary hazard (groupI) occupancies have low False
combustibility, moderate amounts of combustibles
may exceed 12 feet...


, Ohio Sprinkler Technician Practice Test
Exam Review 100% Guaranteed Pass!

9. A valve or device designed for the purpose of reduc- Pressure regulating
ing downstream under flowing (residual) conditions valve
only is a...

10. For large drop sprinkler the maximum distance from Not exceeding one
the sprinkler to the wall shall be... half of the allow-
able distance be-
tween sprinklers

11. For extended coverage sidewall spray sprinklers, Ceilings and roofs
the deflection of sprinklers shall be aligned to...

12. For stages greater than 1,000 square feet in area, 3
they shall be equipped with a class... standpipe
system with 1.5 inch and 2.5 inch hose connections
on each side of the stage.

13. In the NFPA 13D standard, sprinklers shall not be True
required in the bathrooms of 55 square feet or less...

14. Manual standpipe systems shall not be used in True
high-rise buildings...

15. All fire department connections shall be supplied Listed check valve
with... near the point where
it joins the system

16. Dry standpipes shall only be used where piping is True
subject to freezing...

17. Used sprinkler may be used in new sprinkler instal- False
lations as long as the tenant is notified of their use...

18. Sidewall sprinklers shall only be installed as fol- "ALL OF THE
lowed... ABOVE" - Light haz-
ard occupancies with
smooth, horizontal or
sloped, flat bind-
ings. - Ordinary haz-

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Accurate. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for £10.71. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75759 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now

Start selling
£10.71
  • (0)
  Add to cart