ICC Commercial Building Inspector Practice test questions 2 Questions and Answers Fully Solved
7 views 0 purchase
Module
ICC
Institution
ICC
ICC Commercial Building Inspector Practice test questions 2 Questions and Answers Fully Solved
What is the maximum allowable length of glass used in jalousies?
48"
3 multiple choice options
Adobe masonry units used in Type V construction shall have an average compressive strength of _____...
icc commercial building inspector practice test qu
what is the maximum allowable length of glass used
adobe masonry units used in type v construction sh
a penetration through a smoke barrier assembly
Written for
ICC
ICC
All documents for this subject (245)
Seller
Follow
julianah420
Reviews received
Content preview
ICC Commercial Building Inspector
Practice test questions 2 Questions and
Answers Fully Solved
What is the maximum allowable length of glass used in jalousies? - answer48"
Adobe masonry units used in Type V construction shall have an average compressive
strength of _______ when tested in accordance with ASTM C 67. - answer300 psi
Which of the following emergency escape and rescue openings complies with the code?
- answera net clear opening 27 inches high by 27 inches wide at the ground floor level
A penetration through a smoke barrier assembly shall _____________. - answerbe
protected by an approved through-penetration firestop system
A 400 square foot laundry chute discharge room, separated from the remainder of the
building by 1 hour fire rated construction, has a 45 minute rated door which is self-
closing up on the detection of smoke: - answerpass the inspection, complies with the
code
Means of egress doors used for the movement of beds in Group I-2 shall provide a clear
width: - answerall of the options comply with the code
Interior spaces intended for human occupancy shall be provided with a space heating
system capable of maintaining an indoor temperature of... - answer68 degrees F. 36"
above the floor
According to the International Building Code 2018 when the approved plans call for 2
No. 4 reinforcing bars in a footing and the inspector discovers that 2 No. 5 bars are
installed, which of the following is correct? - answerresubmit the plans for approval as
an amended set
A private garage, Group U, shall be separated from a one story dwelling unit, Group R-
3, by means of gypsum board not less than __________. - answer1/2", applied to the
garage side
Which type of valley lining metal requires a minimum thickness of 0.027"? - answerZinc
alloy
, Canopies under which fuels are dispensed shall have a clear, unobstructed height of: -
answernot less than 13'-6"
Public swimming pools shall be designed and constructed in accordance with
___________________. - answerInternational Swimming Pool Code
Which of the following best describes an automatic wet standpipe? - answera system
with a water supply capable of supplying the system demand automatically
What is the minimum fire resistance rating required when a fire barrier is constructed to
separate fire areas between a Group U and a Group S-2 occupancy? - answer2 hours
In an attic space without a vapor barrier, the net free ventilating area shall be not less
than ______ of the area, assuming all ventilation is located in the eaves. - answer1/150
The use of a building for the gathering of persons specifically for the purposes of
religious functions with an occupant load of 300 would be classified as a _________
occupancy. - answerAssembly Group A-3
Each continuous, vertical section of a wall, one masonry unit in thickness, is defined as:
- answera wythe
Construction documents shall designate the number of occupants to be accommodated
on every floor, and in all rooms and spaces, except for _________, regarding all
portions of the means of egress. - answera Group R-3, Residential, 6 unit, 2 story
townhouse
To achieve a 4 hour fire rating for a lightweight concrete floor slab, the minimum
thickness will be: - answer5.1 inches
A smoke control system has a fire fighter's control panel with status indicators. The pilot
lamp is amber. What is the status of the system? - answerfault
What is the minimum lap for fiber cement lap siding? - answer1-1/4 inch
Buildings shall have a fire resistance rating. When altered or extended in height a
building shall be classified in one of the _______ types of construction for this purpose.
- answerfive
Parapet walls shall be properly coped with noncombustible, weatherproof materials
having a width _______________________. - answerno less than the thickness of the
parapet wall
Bearing and exterior wall studs shall be capped with double top plates having their end
joints offset at least _______. - answer48"
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for £14.75. You're not tied to anything after your purchase.