Exam (elaborations)

Unit 36 Refrigeration Applied to Air Conditioning Questions and Answers 100% Correct

 15 views  0 purchase
  • Module
  • Unit 36 Refrigeration Applied to Air Conditioning
  • Institution
  • Unit 36 Refrigeration Applied To Air Conditioning

Unit 36 Refrigeration Applied to Air Conditioning Questions and Answers 100% CorrectUnit 36 Refrigeration Applied to Air Conditioning Questions and Answers 100% CorrectUnit 36 Refrigeration Applied to Air Conditioning Questions and Answers 100% CorrectUnit 36 Refrigeration Applied to Air Conditioni...

[Show more]

Preview 3 out of 23  pages

  • September 19, 2024
  • 23
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Unit 36 Refrigeration Applied to Air Conditioning
  • Unit 36 Refrigeration Applied to Air Conditioning
avatar-seller
Unit 36 Refrigeration Applied to
Air Conditioning Questions and
Answers 100% Correct
comfort cooling - ANSWER - Air-Conditioning


Refrigeration process applied to _____________________


high-temperature - ANSWER - Air-Conditioning


Classified as a ___________________________ refrigeration system


Compressor, condenser, metering device, evaporator - ANSWER - Air-Conditioning


Uses the same four components as other refrigeration systems
___________________, ____________________, __________________, and
____________________


indoors, outside - ANSWER - Air-Conditioning


Absorbs heat _______________ and puts it _____________


conduction, infiltration, radiation - ANSWER - Structural Heat Gain


Heat leaks into a structure by ________________, _________________, and
________________


higher - ANSWER - Structural Heat Gain

,Summer solar load on a structure is _____________ on east and west sides


Attic ventilation, powered, natural-draft - ANSWER - Structural Heat Gain


_____________________ can help relieve solar load on the ceiling
Accomplished with _________________ or ________________ ventilation systems


walls, closed windows, closed doors, cracks - ANSWER - Structural Heat Gain:
Conduction and Infiltration


Heat enters through ________, ________________, and _____________________ by
conduction, and by infiltration through ____________ around the doors and windows


Infiltrating air - ANSWER - Structural Heat Gain: Conduction and Infiltration


________________ has different characteristics (humidity), depending on location, that
must be taken into account


low - ANSWER - Evaporative Cooling


Used primarily in climates with ________ humidity


water, evaporation, outlet, pressurize, Drip, spray or singer, rotary - ANSWER -
Evaporative Cooling


Uses fiber mounted in a frame with __________ running over the fiber as cooling
media
Fresh air is drawn through the fiber and cooled by _________________
Must be an _____________ for air that has entered to leave the structure or it will
________________
Three common configurations:

, _________-type swamp cooler, the ___________________-type swamp cooler, and the
___________-type swamp cooler


operate, same - ANSWER - Package-Type and Split-Type Air-Conditioning Systems


Air-conditioning, comfort cooling, or high-temperature refrigeration systems
_______________ with the ____________ four main system components


Package air-conditioning - ANSWER - Package-Type and Split-Type Air-Conditioning
Systems


Self-contained; all components in one cabinet with air ducted to and from the unit


Split-system air-conditioning, popular - ANSWER - Package-Type and Split-Type Air-
Conditioning Systems


Condenser outside; removed from evaporator; connected by refrigerant lines
Ductless split system very __________


air, refrigerant, sensible, latent - ANSWER - The Evaporator


Transfers heat from _______ to ______________
Absorbing ____________ heat lowers air temperature
Absorbing ___________ heat removes moisture by changing water vapor to
condensate, which is drained


75 degrees F, 50%, 62.5 degrees F - ANSWER - The Evaporator


Typical room conditions: _________ dry-bulb temperature, ________ relative humidity,
________ wet-bulb temperature


40 degrees F - ANSWER - The Evaporator

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller NursingTutor1. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for £10.37. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

85443 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now

Start selling
£10.37
  • (0)
  Add to cart