The basic unit for measuring current flow is:
a. atomic weight
b. Coulomb
c. Volt
d. Ampere - d. ampere
The basic unit of resistance is:
a. Ohm
b. Coulomb
c. Ampere
d. Volt - a. ohm
Which of the following is NOT a valid expression ...
[Show more]
Preview 4 out of 204 pages
Uploaded on
January 9, 2025
Number of pages
204
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
Institution
EEG
Module
EEG
£11.31
Also available in package deal from £130.05
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
Also available in package deal (1)
EEG Bundled Exams Questions and Answers 100% Pass Guaranteed| 40% Discount Off!!
£ 313.62
£ 130.05
30 items
1. Exam (elaborations) - Electroencephalography (eeg) exam questions and answers 100% pass
2. Exam (elaborations) - Prep u ch. 65electroencephalogram (eeg) exam questions and answers 100% pass
3. Exam (elaborations) - Midterm exam normal electroencephalography questions and answers 100% pass
4. Exam (elaborations) - Lecture 3 & 4: electroencephalography (eeg) exam questions and answers 100% pass
5. Exam (elaborations) - Eeg terminology set 1 questions and answers 100% pass
6. Exam (elaborations) - Eeg study guide for registry (aset review questions) with correct answers
7. Exam (elaborations) - Eeg semester 1 102-2 exam questions and answers 100% pass
8. Exam (elaborations) - Eeg mock exam questions and answers 100% pass
9. Exam (elaborations) - Eeg review questions 1-150 exam with correct answers
10. Exam (elaborations) - Eeg mock exam questions and answers 100% pass
11. Exam (elaborations) - Eeg lesson 1 exam questions and answers 100% pass
12. Exam (elaborations) - Final exam (end 201, 202, and 203) questions and answers 100% pass
13. Exam (elaborations) - Eeg exam practice questions and answers 100% pass
14. Exam (elaborations) - Eeg boards part 2 practice test questions and answers 100% pass
15. Exam (elaborations) - eeg boards mock exam questions and answers 100% pass
16. Exam (elaborations) - eeg board prep (part 1) questions and answers 100% pass
17. Exam (elaborations) - Eeg board prep asap test prep questions and answers 100% pass
18. Exam (elaborations) - Eeg board prep mock exam #2 questions and answers 100% pass
19. Exam (elaborations) - Eeg board prep questions and answers 100% pass
20. Exam (elaborations) - Eeg board prep questions and answers 100% pass
21. Exam (elaborations) - Eeg board exam questions and answers 100% pass
22. Exam (elaborations) - Eeg board exam practice questions and answers 100% pass
23. Exam (elaborations) - Eeg board exam questions and answers 100% pass
24. Exam (elaborations) - Eeg 211 final exam review questions and answers 100% pass
25. Exam (elaborations) - Eeg 210- final exam review questions and answers 100% pass
26. Exam (elaborations) - Eeg210 final exam review questions and answers 100% pass
27. Exam (elaborations) - Eeg 203 final review questions and answers 100% pass
28. Exam (elaborations) - Eeg 101 final exam questions and answers 100% pass
29. Exam (elaborations) - Definitions for eeg – eeg exam questions and answers 100% pass
30. Exam (elaborations) - Anatomy and physiology: eeg lab exam questions and answers 100% pass
Show more
1|Page
EEG BOARD Prep (Part 1) Questions
and Answers 100% Pass
The basic unit for measuring current flow is:
a. atomic weight
b. Coulomb
c. Volt
d. Ampere - ✔✔d. ampere
The basic unit of resistance is:
a. Ohm
b. Coulomb
c. Ampere
d. Volt - ✔✔a. ohm
Which of the following is NOT a valid expression of Ohm's Law:
a. R=EI or (R=VI)
b. E=IR or (V=IR)
c. I=E/R or (I=V/R)
d. R=E/I or (R=V/I) - ✔✔a. R=EI or (R=VI)
Author. Emily Charlene, ©2025 All Rights Reserved.
,2|Page
Which of the following is NOT a unit for measuring alternating frequencies:
a. cycles per second
b. volts
c. hertz
d. kilocycles - ✔✔b. volts
Which of the following describes the action of a capacitor?
a. opposes changes in current flow
b. converts A/C to D/C
c. creates a direct current resistance
d. stores energy - ✔✔d. stores energy
A circuit that allows some frequencies to pass through it, while others are blocked is a:
a. resistor
b. transistor
c. filter
d. reactor - ✔✔c. filter
A combination of electronic components designed to increase the power, voltage or current of a signal:
a. amplifier
b. line filter
c. master gain control
d. sensitivity - ✔✔a. amplifier
Author. Emily Charlene, ©2025 All Rights Reserved.
,3|Page
A small fluctuating output recorded by the EEG instrument even when there is no input signal is called:
a. output voltage
b. linear distortion
c. 60Hz interference
d. noise - ✔✔d. noise
The EEG amplifier is designed so that when input 1 is more negative than input 2, the deflection will be -
✔✔upward
Common mode rejection is:
a. the ability of an amplifier to cancel out ECG artifact
b. the characteristic of an amplifier that rejects external interference
c. is dependent on the sampling rate
d. controlle by the 60-cycle notch filter - ✔✔b. the characteristic of an amplifier that rejects external
interference
Which of the following is most attenuated by a low frequency filter of 1 Hz?
a. 0.5 Hz
b. 5.0 Hz
c. 10.0 Hz
d. 0.1 Hz - ✔✔d. 0.1 Hz
Time constant is defined as the time required for the deflection to fall (decay):
a. to 47% of the peak deflection
Author. Emily Charlene, ©2025 All Rights Reserved.
, 4|Page
b. 57% of the peak deflection
c. 77% of the peak deflection
d. to 37% of the peak deflection - ✔✔d. to 37% of the peak deflection
An EEG record has 3/sec spike & wave discharges. Both the spike and the slow wave have voltages of
100uV. If this discharge is recorded with a LFF of 5Hz and a sensitivity of 10uV/mm, what would be the
deflection of the spike and the wave?
a. spike 10mm & wave 6mm
b. spike 6mm & wave 10mm
c. spike 10mm & wave 10mm
d. spike 6mm & wave 6mm - ✔✔a. spike 10mm wave 6mm
A high frequency setting of 35Hz would attenuate 50Hz muscle activity by approximately what
percentage:
a. 10%
b. 20%
c. 40%
d. 100% - ✔✔c. 40%
According to ACNS Guidelines, Recording on Clinical EEG on Digital Media requires monitors to have
between 25 & 35mm/second horizontal scaling and a:
a. maximum of 1,000 data points/second to accurately display EEG on the monitor screen
b. minimum of 100 data points/second to accurately display EEG on the monitor screen
c. maximum of 100 data points/second to accurately display EEG on the monitor screen