Package deal
BICSI BUNDLE/ LATEST UPDATE
BICSI Practice Test-RETAKE. Top Exam Questions and answers. Latest update. VERIFIED. BICSI IN225 7, BICSI IN250 BICSI TDMM12 BICSI OSP BICSI Installer 2
[Show more]BICSI Practice Test-RETAKE. Top Exam Questions and answers. Latest update. VERIFIED. BICSI IN225 7, BICSI IN250 BICSI TDMM12 BICSI OSP BICSI Installer 2
[Show more]BICSI Installer 1, Top Questions and answers, 100% Accurate. Graded A+ 
 
 
25-pair color code - -White - Blue, orange, green, brown, slate 
Red - Blue, orange, green, brown, slate 
Black - Blue, orange, green, brown, slate 
Yellow - Blue, orange, green, brown, slate 
Violet - Blue, orange, green, b...
Preview 3 out of 17 pages
Add to cartBICSI Installer 1, Top Questions and answers, 100% Accurate. Graded A+ 
 
 
25-pair color code - -White - Blue, orange, green, brown, slate 
Red - Blue, orange, green, brown, slate 
Black - Blue, orange, green, brown, slate 
Yellow - Blue, orange, green, brown, slate 
Violet - Blue, orange, green, b...
BICSI - Installer 1 – Exam Review Questions and answers, 100% Accurate. Graded A+ 
BICSI - Installer 1 – Exam Review Questions and answers, 100% Accurate. Graded A+ 
B 
A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______? 
 
A 5 m (16.5') 
B 10 m (33') 
C...
Preview 4 out of 49 pages
Add to cartBICSI - Installer 1 – Exam Review Questions and answers, 100% Accurate. Graded A+ 
BICSI - Installer 1 – Exam Review Questions and answers, 100% Accurate. Graded A+ 
B 
A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______? 
 
A 5 m (16.5') 
B 10 m (33') 
C...
BICSI Practice Test-RETAKE. Top Exam Questions and answers. Latest update. VERIFIED. 
 
 
The 2 main considerations concerning the existing cabling are? - -Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is ...
Preview 2 out of 11 pages
Add to cartBICSI Practice Test-RETAKE. Top Exam Questions and answers. Latest update. VERIFIED. 
 
 
The 2 main considerations concerning the existing cabling are? - -Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is ...
BICSI ITSMM, Top Exam Questions and 
answers. 100% Accurate. Graded A+
Preview 2 out of 8 pages
Add to cartBICSI ITSMM, Top Exam Questions and 
answers. 100% Accurate. Graded A+
BICSI Exam Review Questions and answers, 100% Accurate, rated A+
Preview 2 out of 12 pages
Add to cartBICSI Exam Review Questions and answers, 100% Accurate, rated A+
BICSI RTPM, Top Exam Questions and answers, 100% Accurate. VERIFIED. 
 
 
design and implementation/installation - -Telecommunications project management (TPM) typically consists of two distinct processes: 
 
Design PM Tasks - -Review expression of interest for client 
Perform a user needs analysis...
Preview 4 out of 41 pages
Add to cartBICSI RTPM, Top Exam Questions and answers, 100% Accurate. VERIFIED. 
 
 
design and implementation/installation - -Telecommunications project management (TPM) typically consists of two distinct processes: 
 
Design PM Tasks - -Review expression of interest for client 
Perform a user needs analysis...
BICSI Installer 2: Fiber Module. Top Exam Questions and answers. Graded A+ 
 
 
Code - -Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - -National electric code 
 
Frequency conversion chart - -One thousand hertz = 1KHz 
 
One millio...
Preview 2 out of 11 pages
Add to cartBICSI Installer 2: Fiber Module. Top Exam Questions and answers. Graded A+ 
 
 
Code - -Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - -National electric code 
 
Frequency conversion chart - -One thousand hertz = 1KHz 
 
One millio...
BICSI IN250 Optical Fiber Review Questions and answers. 100% Accurate. VERIFIED. 
 
 
SAFETY REVIEW 
OSHA - -Occupational Safety and Health Administration 
 
What is the 1st step you should take to safely assist an injured person during an emergency? - -Survey the Scene 
 
When Surveying a Victim wh...
Preview 2 out of 11 pages
Add to cartBICSI IN250 Optical Fiber Review Questions and answers. 100% Accurate. VERIFIED. 
 
 
SAFETY REVIEW 
OSHA - -Occupational Safety and Health Administration 
 
What is the 1st step you should take to safely assist an injured person during an emergency? - -Survey the Scene 
 
When Surveying a Victim wh...
BICSI IN250 Optical Fiber Review 
Questions and answers. 100% Accurate. 
VERIFIED. 
SAFETY REVIEW 
OSHA - -Occupational Safety and Health Administration 
What is the 1st step you should take to safely assist an injured person during an emergency? - - 
Survey the Scene
Preview 2 out of 11 pages
Add to cartBICSI IN250 Optical Fiber Review 
Questions and answers. 100% Accurate. 
VERIFIED. 
SAFETY REVIEW 
OSHA - -Occupational Safety and Health Administration 
What is the 1st step you should take to safely assist an injured person during an emergency? - - 
Survey the Scene
BICSI Technician HW #2. Top Exam Questions and answers, 100% Accurate. VERIFIED. 
 
 
The function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? - Backbone cable 
 
The main components of backbone cabling are cabling pathways, cables, mis...
Preview 1 out of 4 pages
Add to cartBICSI Technician HW #2. Top Exam Questions and answers, 100% Accurate. VERIFIED. 
 
 
The function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? - Backbone cable 
 
The main components of backbone cabling are cabling pathways, cables, mis...
BICSI Installer 2, Top Exam Questions & Answers, 100% Accurate. 
 
 
1 
KEY TERMS 
 
Choose Correct Term: 
 
1. Attenuation, 2. Bandwidth, 3. Cable Loss, 4. Cladding, 5. Connector, 6. Dispersion, 7. Ferrule (Optical Fiber), 8. FC, 9. Furcating Harness, 10. Insertion Loss, 11. LC Connector/Adapter, 1...
Preview 4 out of 91 pages
Add to cartBICSI Installer 2, Top Exam Questions & Answers, 100% Accurate. 
 
 
1 
KEY TERMS 
 
Choose Correct Term: 
 
1. Attenuation, 2. Bandwidth, 3. Cable Loss, 4. Cladding, 5. Connector, 6. Dispersion, 7. Ferrule (Optical Fiber), 8. FC, 9. Furcating Harness, 10. Insertion Loss, 11. LC Connector/Adapter, 1...
BICSI 1 & 2, Top Exam Questions & Answers, 100% Accurate. Rated A+ 
 
 
TIA/EIA - -Telecommunications Industry Association / Electronic Industries Alliance 
 
TIA/EIA-568-C.0 - -Generic Telecommunications Cabling for Customer Premises 
 
TIA-568-C.1 - -Commercial Building Telecommunications Cabling ...
Preview 3 out of 28 pages
Add to cartBICSI 1 & 2, Top Exam Questions & Answers, 100% Accurate. Rated A+ 
 
 
TIA/EIA - -Telecommunications Industry Association / Electronic Industries Alliance 
 
TIA/EIA-568-C.0 - -Generic Telecommunications Cabling for Customer Premises 
 
TIA-568-C.1 - -Commercial Building Telecommunications Cabling ...
BICSI IN225 7.0, Installer 2, Copper. Exam Review Question Sections & Answers. Rated A+ 
 
 
Attenuation - -The Decrease in magnitude or power loss of a signal. 
 
Decibels, dB - -Unit of measurement for attenuation. 
 
American Wire Gauge (AWG) - -The numerical system for designating wire diameter....
Preview 4 out of 33 pages
Add to cartBICSI IN225 7.0, Installer 2, Copper. Exam Review Question Sections & Answers. Rated A+ 
 
 
Attenuation - -The Decrease in magnitude or power loss of a signal. 
 
Decibels, dB - -Unit of measurement for attenuation. 
 
American Wire Gauge (AWG) - -The numerical system for designating wire diameter....
BICSI chapter 5. Top Exam Questions & Answers, 100% Accurate. 
 
 
high pair count cable can be loaded onto reels that are up too - -2 meters (6.5 FT high) and 1.5meters (5 FT wide) 
 
elements common to all cabling installation projects - -knowledge of industry standards and codes 
understanding th...
Preview 1 out of 4 pages
Add to cartBICSI chapter 5. Top Exam Questions & Answers, 100% Accurate. 
 
 
high pair count cable can be loaded onto reels that are up too - -2 meters (6.5 FT high) and 1.5meters (5 FT wide) 
 
elements common to all cabling installation projects - -knowledge of industry standards and codes 
understanding th...
BICSI Installer 2, Copper, Chapter 1, Balanced Twisted Pair Cable. Top Exam Questions & Answers, Rated A+ 
 
 
Balanced twisted-pair cables have a nominal characteristic impedance of - -100 ohms at 100 MHz 
 
Insulation - -Copper wires must be physically separated 
 
UTP - -unshielded twisted-pair 
...
Preview 2 out of 11 pages
Add to cartBICSI Installer 2, Copper, Chapter 1, Balanced Twisted Pair Cable. Top Exam Questions & Answers, Rated A+ 
 
 
Balanced twisted-pair cables have a nominal characteristic impedance of - -100 ohms at 100 MHz 
 
Insulation - -Copper wires must be physically separated 
 
UTP - -unshielded twisted-pair 
...
BICSI Installer 2, Copper, Chapter 2. Top 
Exam Questions and answers, 100% 
Accurate. Rated A+
Preview 2 out of 11 pages
Add to cartBICSI Installer 2, Copper, Chapter 2. Top 
Exam Questions and answers, 100% 
Accurate. Rated A+
Systems Verification BICSI Final, Top Exam Questions & Answers, Graded A+
Preview 4 out of 35 pages
Add to cartSystems Verification BICSI Final, Top Exam Questions & Answers, Graded A+
BICSI chapter 4, Top Exam Questions & Answers, 100% Accurate, rated A+ 
 
 
In the absence of a specified distance, what is the minimum space front and back for work area? - -Minimum of, 3.3 feet front and back workspace.
Preview 1 out of 4 pages
Add to cartBICSI chapter 4, Top Exam Questions & Answers, 100% Accurate, rated A+ 
 
 
In the absence of a specified distance, what is the minimum space front and back for work area? - -Minimum of, 3.3 feet front and back workspace.
BICSI's ICT Terminology Handbook (Version 1.0). Exam Questions & Answers, rated A+ 
 
 
Administration - -The method for labeling, documentation, and usage needed to implement moves, additions, and changes of the telecommunications infrastructure. 
 
Alien Crosstalk - -A measure of the unwanted sig...
Preview 2 out of 5 pages
Add to cartBICSI's ICT Terminology Handbook (Version 1.0). Exam Questions & Answers, rated A+ 
 
 
Administration - -The method for labeling, documentation, and usage needed to implement moves, additions, and changes of the telecommunications infrastructure. 
 
Alien Crosstalk - -A measure of the unwanted sig...
BICSI Technician- Netcom - Chapter 1 exam Questions & Answers, rated A+ 
 
 
Three transmission methods are - -Symplex, half duplex, full duplex
Preview 3 out of 17 pages
Add to cartBICSI Technician- Netcom - Chapter 1 exam Questions & Answers, rated A+ 
 
 
Three transmission methods are - -Symplex, half duplex, full duplex
1x sold
BICSI OSP, Exam Review Questions & Answers, 100% Accurate. VERIFIED. 
 
 
If lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be_____ than suspension strand. - -One SIze Larger
Preview 2 out of 12 pages
Add to cartBICSI OSP, Exam Review Questions & Answers, 100% Accurate. VERIFIED. 
 
 
If lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be_____ than suspension strand. - -One SIze Larger
BICSI Exam Questions and answers. Graded A+/ latest updates. 
 
 
T or F: A STANDARD can be described as "a rule or set of rules intended to ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related objects. - False (describes Codes) 
 
A _____...
Preview 1 out of 4 pages
Add to cartBICSI Exam Questions and answers. Graded A+/ latest updates. 
 
 
T or F: A STANDARD can be described as "a rule or set of rules intended to ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related objects. - False (describes Codes) 
 
A _____...
BICSI Installer 2: Fiber Module. Top Questions & Answers, 100% Accurate. Graded A+ 
 
 
Code - -Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - -National electric code 
 
Frequency conversion chart - -One thousand hertz = 1KHz
Preview 2 out of 11 pages
Add to cartBICSI Installer 2: Fiber Module. Top Questions & Answers, 100% Accurate. Graded A+ 
 
 
Code - -Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - -National electric code 
 
Frequency conversion chart - -One thousand hertz = 1KHz
BICSI TDMM12 Chapter 12 Top Exam Questions & Answers, 100% Accurate. 
 
 
*Figure 12.1-Pic on test-Transposed pairs - -2 pairs wrong on 1 end (12-2) 
 
Propagation delay = - -A measurement of the time for signal to travel from one end of the transmission path to the other (12-4) 
 
TDR troubleshooti...
Preview 1 out of 2 pages
Add to cartBICSI TDMM12 Chapter 12 Top Exam Questions & Answers, 100% Accurate. 
 
 
*Figure 12.1-Pic on test-Transposed pairs - -2 pairs wrong on 1 end (12-2) 
 
Propagation delay = - -A measurement of the time for signal to travel from one end of the transmission path to the other (12-4) 
 
TDR troubleshooti...
BICSI TDMM12 Chapter 13. Top Exam Questions and answers, 100% Accurate. Rated A+ 
 
 
The first step on a project should be a review of the _________ from the previous project. - -lessons learned (13-4) 
 
In project management, an organization breakdown structure (OBS) is used to answer the questio...
Preview 1 out of 2 pages
Add to cartBICSI TDMM12 Chapter 13. Top Exam Questions and answers, 100% Accurate. Rated A+ 
 
 
The first step on a project should be a review of the _________ from the previous project. - -lessons learned (13-4) 
 
In project management, an organization breakdown structure (OBS) is used to answer the questio...
BICSI TDMM12 Chapter 4. Top Questions & Answers, 100% Accurate. Graded A+ 
 
 
Work area components include: - -Telecommunications outlet/connector, Work area cable (cord) MUTOA, WAP, NIC (4-1) 
 
In modular jack connections, the acronym 8P8C stands for: - -8-position, 8-contact (4-2) 
 
Figure 4.1 ...
Preview 2 out of 5 pages
Add to cartBICSI TDMM12 Chapter 4. Top Questions & Answers, 100% Accurate. Graded A+ 
 
 
Work area components include: - -Telecommunications outlet/connector, Work area cable (cord) MUTOA, WAP, NIC (4-1) 
 
In modular jack connections, the acronym 8P8C stands for: - -8-position, 8-contact (4-2) 
 
Figure 4.1 ...
BICSI TDMM12 Chapter 24. Top Exam Questions & Answers, Graded A+ 
 
 
Residential cabling consisting of a minimum of one 4-pair CAT5e (or higher) balanced twisted-pair cable and one 75-ohm Series 6 coaxial cable is classified as: - -Grade 1 (24-2) 
 
______ residential cabling is required to support...
Preview 1 out of 2 pages
Add to cartBICSI TDMM12 Chapter 24. Top Exam Questions & Answers, Graded A+ 
 
 
Residential cabling consisting of a minimum of one 4-pair CAT5e (or higher) balanced twisted-pair cable and one 75-ohm Series 6 coaxial cable is classified as: - -Grade 1 (24-2) 
 
______ residential cabling is required to support...
BICSI TDMM12 Chapter 19. Exam Questions and answers, 100% Accurate. 
 
 
ESS stands for - -Electronic Safety & Security (19-1) 
 
*Risk formula - -Risk = (Threat x Vulnerability)/Countermeasures (test) (19-7) 
 
The science of EAC is a means of regulating access to specific: - -Physical Space, Resou...
Preview 1 out of 3 pages
Add to cartBICSI TDMM12 Chapter 19. Exam Questions and answers, 100% Accurate. 
 
 
ESS stands for - -Electronic Safety & Security (19-1) 
 
*Risk formula - -Risk = (Threat x Vulnerability)/Countermeasures (test) (19-7) 
 
The science of EAC is a means of regulating access to specific: - -Physical Space, Resou...
BICSI TDMM12 Chapter 23, Top Exam Questions and answers. Graded A+ 
 
 
Two categories of public telephones= - -Coin telephones, Noncoin telephones (23-2) 
 
Advantages of booths: - -Max privacy, Min. noise interference, Seating capability, Weather protection (not cost) (23-2) 
 
**FCC has changed T...
Preview 1 out of 2 pages
Add to cartBICSI TDMM12 Chapter 23, Top Exam Questions and answers. Graded A+ 
 
 
Two categories of public telephones= - -Coin telephones, Noncoin telephones (23-2) 
 
Advantages of booths: - -Max privacy, Min. noise interference, Seating capability, Weather protection (not cost) (23-2) 
 
**FCC has changed T...
BICSI TDMM12 Chapter 15, Top Exam Questions & Answers, 100% Accurate. Graded A+ 
 
 
Two technologies in paging systems - -Centrally amplified systems, Distributed amplified systems (15-3) 
 
Jet airplane takeoff noise level = - -Exceeds 100 dB (15-7) 
 
Doctors exam room noise level = - -55 dB (15-...
Preview 1 out of 2 pages
Add to cartBICSI TDMM12 Chapter 15, Top Exam Questions & Answers, 100% Accurate. Graded A+ 
 
 
Two technologies in paging systems - -Centrally amplified systems, Distributed amplified systems (15-3) 
 
Jet airplane takeoff noise level = - -Exceeds 100 dB (15-7) 
 
Doctors exam room noise level = - -55 dB (15-...
BICSI Practice Test-RETAKE Questions and answers, 100% Accurate. VERIFIED. 
 
 
The 2 main considerations concerning the existing cabling are? - -Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is called a -...
Preview 2 out of 11 pages
Add to cartBICSI Practice Test-RETAKE Questions and answers, 100% Accurate. VERIFIED. 
 
 
The 2 main considerations concerning the existing cabling are? - -Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is called a -...
BICSI RTPM 002 section 1 Site Survey, Top Questions and answers, 100% Accurate. Rated A+ 
 
 
Pathway Considerations - -In planning for OSP cabling, cable infrastructure must be determined irst. The choices are underground, direct-buried, and aerial. 
 
Underground plant - -most expensive system, ha...
Preview 1 out of 3 pages
Add to cartBICSI RTPM 002 section 1 Site Survey, Top Questions and answers, 100% Accurate. Rated A+ 
 
 
Pathway Considerations - -In planning for OSP cabling, cable infrastructure must be determined irst. The choices are underground, direct-buried, and aerial. 
 
Underground plant - -most expensive system, ha...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller PassPoint02. Stuvia facilitates payment to the seller.
No, you only buy these notes for £29.51. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
62890 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now