Package deal
NERC EXAMS AND STUDY GUIDES COMPILATION PACKAGE DEAL.
NERC EXAMS AND STUDY GUIDES COMPILATION PACKAGE DEAL.
[Show more]NERC EXAMS AND STUDY GUIDES COMPILATION PACKAGE DEAL.
[Show more]The Reliability Coordinator just informed you of a slow time error correction which will begin at the top of the next hour. Your EMS system will not let you change your scheduled frequency. Your Frequency Bias Setting is -100 MW/.1Hz. What action should you take? 
 
A) Increase Net Interchange Sched...
Preview 4 out of 109 pages
Add to cartThe Reliability Coordinator just informed you of a slow time error correction which will begin at the top of the next hour. Your EMS system will not let you change your scheduled frequency. Your Frequency Bias Setting is -100 MW/.1Hz. What action should you take? 
 
A) Increase Net Interchange Sched...
You are an external BA with a frequency bais of 20 MW/.1 Hz that sees a frequency of 60.02 due to a large loss of load in the contingent BA. If your generator governor control systems responded to the frequency deviation approximately how much of a generation change would you BA experience? 
-4MW 
 ...
Preview 3 out of 29 pages
Add to cartYou are an external BA with a frequency bais of 20 MW/.1 Hz that sees a frequency of 60.02 due to a large loss of load in the contingent BA. If your generator governor control systems responded to the frequency deviation approximately how much of a generation change would you BA experience? 
-4MW 
 ...
A Balancing Authority notices that Operating Reserve has steadily declined throughout the hour. What is the most likely cause? 
 
a) Loss of a large generator in the area 
b) An inaccurate load forecast 
c) Loss of a major transmission line 
d) A malfunction of EMS 
b) An inaccurate load forecast 
 ...
Preview 2 out of 13 pages
Add to cartA Balancing Authority notices that Operating Reserve has steadily declined throughout the hour. What is the most likely cause? 
 
a) Loss of a large generator in the area 
b) An inaccurate load forecast 
c) Loss of a major transmission line 
d) A malfunction of EMS 
b) An inaccurate load forecast 
 ...
Which type of relay operates on the premise of comparing the flow in and out of the area of protection? 
Differential relay 
 
 
Underfrequency load shedding is set-up so that which of the following does NOT occur? 
Uncontrolled separation 
 
 
Who is responsible to make sure that the operation of v...
Preview 1 out of 2 pages
Add to cartWhich type of relay operates on the premise of comparing the flow in and out of the area of protection? 
Differential relay 
 
 
Underfrequency load shedding is set-up so that which of the following does NOT occur? 
Uncontrolled separation 
 
 
Who is responsible to make sure that the operation of v...
Common standard time period for station battery to handle outage of AC power to chargers 
8-12 hours 
 
 
Time to restore data exchange redundancy when redundancy testing by RC/TOP/BA deemed unsuccessful 
2 hours 
 
 
Transition period to backup control facility (fully functioning) 
2 hours 
 
 
Ann...
Preview 3 out of 17 pages
Add to cartCommon standard time period for station battery to handle outage of AC power to chargers 
8-12 hours 
 
 
Time to restore data exchange redundancy when redundancy testing by RC/TOP/BA deemed unsuccessful 
2 hours 
 
 
Transition period to backup control facility (fully functioning) 
2 hours 
 
 
Ann...
1. If a 500 kV transmission line with a surge impedance loading of 800 MW is currently loaded at 1400 MW, which of the following events would most likely occur? 
 
a. Generator MVAR output would increase 
b. All system capacitors would trip off-line 
c. Generator MVAR output would decrease 
d. All a...
Preview 4 out of 73 pages
Add to cart1. If a 500 kV transmission line with a surge impedance loading of 800 MW is currently loaded at 1400 MW, which of the following events would most likely occur? 
 
a. Generator MVAR output would increase 
b. All system capacitors would trip off-line 
c. Generator MVAR output would decrease 
d. All a...
A transmission line is operating with a voltage phase angle different of 30 degrees between the sending Vs and the receiving bus Vr. If the receiving end load is suddenly increased, the voltage phase angle difference will be? 
The phase angle will increase. When load is increased phase angle will in...
Preview 4 out of 48 pages
Add to cartA transmission line is operating with a voltage phase angle different of 30 degrees between the sending Vs and the receiving bus Vr. If the receiving end load is suddenly increased, the voltage phase angle difference will be? 
The phase angle will increase. When load is increased phase angle will in...
Generating units jointly owned by two or more Balancing Authorities may be modeled in the AGC systems as a "virtual" tie line flow (pseudo-tie). To properly account for the jointly owned unit as a pseudo-tie, each Balancing Authority must include a portion o fthe unit's MW output as an adjustment...
Preview 3 out of 17 pages
Add to cartGenerating units jointly owned by two or more Balancing Authorities may be modeled in the AGC systems as a "virtual" tie line flow (pseudo-tie). To properly account for the jointly owned unit as a pseudo-tie, each Balancing Authority must include a portion o fthe unit's MW output as an adjustment...
1x sold
When using a dynamic schedule and the energy profile in an hour is >250 MW and the actual hourly integration deviates from the hourly energy profile by ____ the tag must be modified. 
A. 100 MW 
B. 10% 
C. 50 MW 
D. 25% 
B. 10% 
 
 
Dry steam plants, flash steam plants, and binary cycle power pla...
Preview 4 out of 98 pages
Add to cartWhen using a dynamic schedule and the energy profile in an hour is >250 MW and the actual hourly integration deviates from the hourly energy profile by ____ the tag must be modified. 
A. 100 MW 
B. 10% 
C. 50 MW 
D. 25% 
B. 10% 
 
 
Dry steam plants, flash steam plants, and binary cycle power pla...
What percentage of load gives a 1 Hz change in an island condition? 6-10% (Think 6-10 day island vacation) If ACE is Zero but system Hz is off, what should a system operator do? Nothing! ACE bi as and interchange schedule will improve frequency If ACE is Zero, why not adjust generation to help frequ...
Preview 4 out of 33 pages
Add to cartWhat percentage of load gives a 1 Hz change in an island condition? 6-10% (Think 6-10 day island vacation) If ACE is Zero but system Hz is off, what should a system operator do? Nothing! ACE bi as and interchange schedule will improve frequency If ACE is Zero, why not adjust generation to help frequ...
If a Balancing Authority does not comply with the Control Performance Standard, the Balancing Authority is not permitted to provide which of the following for any other Balancing Authority entities? 
Regulation of other services related to control performance 
 
 
1. It is the obligation of each Bal...
Preview 4 out of 60 pages
Add to cartIf a Balancing Authority does not comply with the Control Performance Standard, the Balancing Authority is not permitted to provide which of the following for any other Balancing Authority entities? 
Regulation of other services related to control performance 
 
 
1. It is the obligation of each Bal...
1x sold
At what torque angle of operation does power typically begin to flow from the generator to the system? A) 90 degrees B) 60 degrees C) 30 degrees D) 10 degrees 10 degrees Choose the answer that best describes the operation of a rotor. A) The stationary part of the transmission system. B) A type of su...
Preview 3 out of 24 pages
Add to cartAt what torque angle of operation does power typically begin to flow from the generator to the system? A) 90 degrees B) 60 degrees C) 30 degrees D) 10 degrees 10 degrees Choose the answer that best describes the operation of a rotor. A) The stationary part of the transmission system. B) A type of su...
NERC Reliability Coordinator Exam Vocabulary (STUDY GUIDE)
Preview 4 out of 120 pages
Add to cartNERC Reliability Coordinator Exam Vocabulary (STUDY GUIDE)
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller ProfGoodlucK. Stuvia facilitates payment to the seller.
No, you only buy these notes for £20.04. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
73918 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy revision notes and other study material for 14 years now