There shall be a wall switch at each floor to control stairway lighting where the stairway has _____
or more risers 6
Bathtubs should be equipped with the waste outlets and overflow outlets connected to piping at
least _____ inches in diameter 1.5 inches
Doors between the garage and residence s...
Home Inspector National Exam
Questions and Answers Rated A
There shall be a wall switch at each floor to control stairway lighting where the stairway has _____
or more risers ✔✔6
Bathtubs should be equipped with the waste outlets and overflow outlets connected to piping at
least _____ inches in diameter ✔✔1.5 inches
Doors between the garage and residence shall be equipped with a ✔✔Self-closing door
The _____ shall not be considered as an effective ground-fault current path ✔✔Earth
For natural ventilation for habitable rooms, the min openable area to the outdoors shall be _____
percent of the floor area being ventilated ✔✔4%
Fuel gas appliance connectors shall not exceed an overall length of _____ feet ✔✔6 ft.
What size are fuel-gas-fired domestic clothes dryer ducts ✔✔4 inches
The maximum amount of fuel oil stored above ground or inside a building shall be _____ gallons.
✔✔660 gals.
The minimum bet area of ventilation openings shall not be less than _____ square foot for each
_____ square feet of under-floor space ✔✔1 sqft. for each 150 sqft
Foundation anchor bolts shall be at least _____ inch in diameter and shall extend a minimum of
_____ inches into concrete or grouted cells of concrete masonry units ✔✔1/2 in. , 7 in.
,Outdoor and return air for a forced-air heating and cooling system shall not be taken from
✔✔Closets, bathrooms, toilet rooms, kitchens, garages, boiler rooms, furnace rooms,
unconditioned attics, or other dwelling units
Receptacles installed on 15 and 20 ampere rated branch circuits shall be on the _____ type
✔✔Grounding
Ceiling-suspended paddle fans shall be supported ________________ of the outlet box.
✔✔independently
Dwelling units shall be provided with heating facilities capable of maintaining a minimum room
temperature of ✔✔68 *f
Conductors in NM cable assemblies shall be rated at _________ Celsius. ✔✔90 *C
Address numbers shall be a minimum of _____ inches high with a minimum stroke width of _____
inch. ✔✔4 inches , 1/2 inch
Habitable space, hallways, corridors, bathrooms, toilet rooms, laundry rooms and portions of
basements containing these spaces shall have a ceiling height of not less than _______ feet. ✔✔7
feet
A Type B or a Type L gas vent shall terminate at least _____ feet in vertical height above the
highest connected APPLIANCE DRAFT HOOD or FLUE COLLAR. ✔✔5 feet
Open web truss or I-Joist floor assemblies require a ____-inch gypsum wallboard membrane,
____-inch wood structural panel membrane, or the equivalent on the underside. ✔✔1/2 And 5/8
Flanges and lips of load-bearing cold-formed steel floor framing members shall not be cut or ____.
✔✔Notched
,Gas vents over 12 inches in size shall terminate not less than _____ feet above the highest point
where they pass through the roof. ✔✔2 feet
Foundations for masonry chimneys shall be constructed of concrete or solid masonry at least _____
inches thick ✔✔12 inches
Supports and foundations for the outdoor unit of a heat pump shall be raised at least ___ inches
above the ground. ✔✔3 inches
Attic ventilation openings shall have a least dimension of _________ inch minimum to _________
inch maximum openings. ✔✔1/16 And 1/4
All wood beams, joists, studs and other combustible material shall have a clearance of not less
than _____ inches from the front faces and sides of masonry fireplaces. ✔✔2 inches
The minimum headroom in all parts of the stairway shall not be less than _____ feet, _____ inches
✔✔6 feet, 8 inches
A nosing not less than ____ inch but not more than ____ inches shall be provided on stairways
with solid risers. ✔✔3/4 And 1 1/4
Unattached decks not exceeding _____ square feet in area, that are not more than _____ inches
above grade do not require a permit. ✔✔200 sqft. And 30 inches
Gas appliance shut off valves shall be located in the same room as the appliance and not further
than _____ feet from the appliance ✔✔6 feet
BTU is abbreviation for _____ _____ ______, which is the quantity of heat required to raise the
temperature of 1 pound of water 1*F ✔✔British thermal unit
, Stairways shall not be less than ____ inches in clear width at all points above the permitted handrail
height and below the required headroom height. ✔✔36 inches
An automatic fire sprinkler system is not required when _____ or _____ are made to existing
townhouses that do not have a sprinkler system ✔✔Additions and or Alterations
Chimney shall extend at least _____ feet higher than any portion of a building within ____ feet.
✔✔2 feet, 10 feet
Window wells serving emergency escape and rescue openings shall be designed for proper ____.
✔✔Drainage
Braces wall panels shall be constructed with intermittent bracing method s, or the continuous
sheathing methods. Mixing of bracing methods shall be ______. ✔✔Permitted
Physical interconnection of smoke alarms is not required where ____ ___ alarms are installed.
✔✔Listed wireless
(All alarms must sound upon activation of one alarm).
Physical interconnection of smoke alarms is not required where ____ ___ alarms are installed.
✔✔Listed wireless
(All alarms must sound upon activation of one alarm).
A thermal barrier is not required for foam plastic insulation in an attic that is entered only for
purposes of _____ or ______. ✔✔Repairs or Maintenance
ANy portion of a masonry chimney located in the interior of a building or within an exterior wall
shall have a minimum air space clearance to combustibles of _____ inches. ✔✔2 inches
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper BestOfLuck. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €15,47. Je zit daarna nergens aan vast.