PSI National Home Inspector Practice Exam 2023 Questions and Answers with complete solution Which of the following describes partial vapor pressure? A) Water vapor has a tendency to disperse itself equally in the available air. B) Water vapor causes new homes to require house wrap. C) Water...

[Meer zien]

Voorbeeld 2 van de 9  pagina's

  • 16 maart 2023
  • 9
  • 2022/2023
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
avatar-seller
PSI National Home Inspector Practice Exam 2023
Questions and Answers with complete solution
Which of the following describes partial vapor pressure?

A) Water vapor has a tendency to disperse itself equally in the available air.
B) Water vapor causes new homes to require house wrap.
C) Water vapor is common with forced induction natural gas furnaces.
D) Water vapor is an indication of sick house syndrome.
A) Water vapor has a tendency to disperse itself equally in the available air.
In order for soffit vents to operate properly, there MUST be:

A) A clear air channel between the roof boards and the insulation.
B) An absence of insect, bee, and bird nests.
C) Vents on both ends on the outside.
D) Continuous vent strips on the length of the soffit.
A) A clear air channel between the roof boards and the insulation.
Home inspectors report receptacles with reversed polarity as potentially hazardous
because:

A) They contribute to the overheating of the receptacle.
B) They increase the shock likelihood at connected equipment.
C) Single phase appliance motors will run backwards.
D) They trip ground fault circuit interrupter outlets.
B) They increase the shock likelihood at connected equipment.
The term "wet vent" refers to a:

A) Vent that traps water and therefore stays wet.
B) Vent located above the roof line and exposed to rain.
C) Vent that runs outside an exterior wall.
D) Waste line that also functions as a vent.
D) Waste line that also functions as a vent.
EIFS is a siding material that:

A) Is used in commercial buildings only.
B) Looks like stucco but lacks a wire mesh.
C) Can be installed on top of a modified bitumen membrane.
D) Can be installed on top of a masonry surface.
B) Looks like stucco but lacks a wire mesh.
The joints on the exterior of the brick chimney should be:

A) Concaved.
B) Raked.
C) Open.
D) Closed.

, A) Concaved
When a water heater thermostat is set at 140 ° F or higher, a ______ should be
installed to temper the water.

A) Temperature probe
B) Mixing probe
C) Mixing valve
D) Temper valve
C) Mixing valve
In a forced air furnace, the burners are used to generate heat in the:

A) Heat exchanger.
B) Draft diverter.
C) Flue.
D) Plenum.
A) Heat exchanger.
While inspecting a crawl space, you should probe for decay if the _________ is dark in
appearance.

A) King joist
B) Floor joist
C) Masonry wall
D) Bearing wall
B) Floor joist
Which statement BEST describes the action a home inspector should take when a
safety issue is found in a home?

A) Determine the degree of immediacy, and report to the appropriate parties.
B) Explain verbally to the client, but do not include in a written report.
C) Repair the problem when possible.
D) Shut down the system and call a repair contractor.
A) Determine the degree of immediacy, and report to the appropriate parties.
Ivy has grown across the entire exterior brick wall surfaces of a one-family house. The
home inspector should report that the ivy:

A) Will increase the resale value.
B) Will keep the home cooler in the summer.
C) Could cause damage to the surface and recommend removal.
D) Needs additional maintenance and support to remain on the wall surfaces.
C) Could cause damage to the surface and recommend removal.
Which of the following is the correct termination where the sloped roof terminates with
an EIFS wall?

A) Use polyurethane caulking between the gutter and the wall.
B) Use silicone caulking between the gutter and the wall.

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper magdamwikash23. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €10,00. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 82871 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen

Laatst bekeken door jou


€10,00  1x  verkocht
  • (0)
  Kopen