Does a fire hood system and a kitchen need to be monitored by the fire alarm system? --
Yes
What does P.L.F.A stand for?--Power Limited Fire Alarm
What does N.P.L.F.A stand for?--Non-Power Limited Fire...
TFM 12 Fire Alarm Technical Exam Questions with Verified Answers . Does a fire hood system and a kitchen need to be monitored by the fire alarm system? --
Yes What does P.L.F.A stand for? --Power Limited Fire Alarm What does N.P.L.F.A stand for? --Non-Power Limited Fire Alarm What is the difference between P.F.L.A and N.P.F.L.A? --an N.P.L.F.A can operate at up to 600v, and the power output isn't limited a P.L.F.A has the voltage and power limited by a listed power so urce. What material must N.P.F.L.A circuit conductors be made from? --ONLY solid stranded copper is permitted. What does A.W.G stand for? --American Wire Gauge What size conductors are permitted? --Size 18 A.W.G and 16 A.W.G are permitted, provided they do not exceed certain capacities. What is used to protect transformers or other devices supplied from power -supply conductors? --An over -current device not rated over 20 amperes. When located within 7 feet of the floor, how shall cables be fastened? --Cables shall be fastened in an approved manner at intervals of not more than 18 inches. Single conductors shall not be smaller than ___ A.W.G? --18 Conductors of 28 A.W.G shall only be permitted in which circumstance? --Spliced with a connector listed as suitabl e for 26 to 24 A.W.G How shall P.F.L.A conductors NOT be installed? --P.F.L.A conductors shall not be strapped, taped, or attached to the exterior of any conduit or raceway. What is Plenum cable? --Cable that can be installed in ducts, plenums, or other spaces used for environm ental air. What is a Riser cable? --Cable to be used in vertical wire runs in shafts between floors. Not to be used where Plenum cable is required. It is capable of preventing fire from rising from floor to floor. What is general purpose cable? --Cable fo r general purpose fire alarm use. Not to be used where plenum cable or riser cable is required. It is resistant to the spread of fire. Why 'type' shall plenum cable be? What substitutions are allowed? --Power Limited Fire Alarm Plenum (F.P.L.P) C.M.P can be substituted. Why 'type' shall riser cable be? What substitutions are allowed? --Power Limited Fire Alarm Riser (F.P.L.R) C.M.P, F.P.L.P. C.M.R can be substituted. What 'type' shall general purpose wire be? What substitutions are permitted? --Power Limi ted Fire Alarm (F.P.L) C.M.P, F.P.L.P, C.M.R, F.P.L.R, C.M.G
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper AcademiaExpert. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €10,78. Je zit daarna nergens aan vast.