Overlay cold mix can you overlay cold mix? - ANSWER - No
What is ACP? - ANSWER - Asphalt concrete pavement.
What does HMA stand for? - ANSWER - Hot mix asphalt
What does ATP stand fo...
IBC Random Exam – Questions &
Answers (Graded A+)
Overlay cold mix can you overlay cold mix? - ANSWER - No
What is ACP? - ANSWER - Asphalt concrete pavement.
What does HMA stand for? - ANSWER - Hot mix asphalt
What does ATP stand for? - ANSWER - Asphalt treated base
What does RAM stand for? - ANSWER - Request for approval of material.
what standard must be used for structural capacities and design provisions for
prefabricated wood i-joist? - ANSWER - ASTM D 5055
a clear passage with of how many inches minimum must be provided, where an inclined
platform lift or stairway chair lift is installed on stairs stairway serving occupancies in
group R3? - ANSWER - 20 in
egress Court serving group are three and you occupancies must have a minimum width
of how many inches? - ANSWER - 36
the tolerance between the largest and smallest Riser height must not exceed how many
inches in any flight of stairs? - ANSWER - three eighths of an inch
a question mark is a dry standpipe system that is arranged through the use of a device,
such as a deluge valve, to admit water into a system into the system piping upon
activation of a remote control vote device located at a hose connection. a clue is dry -
ANSWER - semi automatic dry
the maximum area of exterior wall openings is what percentage, where the fire
separation system is 15 to less than 20 feet and the building is unprotected and non
sprinkler sprinkled - ANSWER - 25%
true or false, single drinking fountain with two separate spouts is not permitted to
substitute the two separated drinking fountains? - ANSWER - false
where roof slopes towards a parapet at a slope greater than 2 to 12 the parapet must
extend to the same height as any portion of the roof within a fire separation distance
wear protection of the wall opening is required, but in no case must the height be less
than how many inches? - ANSWER - and no case it can't be less than 30 in
, the shear capacity for horizontal wood frame gypsum board diaphragm ceiling
assemblies is how many plf for a gypsum board 1/2 inch thick with 16 on Center
spacing of framing members. - ANSWER - 90 plf
what residential occupancy includes buildings used by more than 5 people with a
maximum of 16 who reside on a 24-hour basis in a supervised residential environment
and receive custodial care? - ANSWER - R4
the minimum space between two doors in a series must be how many inches plus the
width of the door swinging into the - ANSWER - 48 in
in type 1 and 2 Construction, non classified roof coverings are permitted on the
buildings of group are 3 and group you occupancies, where the minimum fire separation
distance of how many feet? Measured from the Leading Edge of the roof - ANSWER - 6
ft 6 ft
a? Isn't approved system of devices and Equipment which it automatically detects of fire
and discharge An approved fire extinguishing agent onto or in the fire area - ANSWER -
automatic fire extinguishing system
the slope of a ramp tiles that are not part of an accessible route must be a Max of -
ANSWER - one unit vertical and 8 units for horizontal
studs in non load-bearing walls and partitions, are not part of a braced wall panel, must
be spaced a minimum of? On Center - ANSWER - 24 in
what Residential Group occupancy includes buildings used by more than five persons
or 16 Max who reside on a 24 hour basis in a supervised residential environment and
receive custodian care - ANSWER - group R 4
minimum airspace of? Must be provided between the insulation and the roof sheathing
of an enclosed attic how many inches? - ANSWER - 1 inch
? unit of masonry composed of glass units funded by mortar - ANSWER - glass
where there is only one elevator it must automatically transferred to standby Power
Within? after failure of normal Power - ANSWER - 60 Seconds
the average dead loads for Combined roof and ceiling, exterior walls, floor and partitions
in light frame construction, must not exceed? - ANSWER - 15 psf
in order to reduce the required open space surrounding certain unlimited area buildings
from 60 ft to 40 ft, the the reduced with must be a maximum of what percentage of the
perimeter of the building? - ANSWER - 75%
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper conceptialresearchers. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €7,42. Je zit daarna nergens aan vast.