Qualification for S98 certificate of fitness include all except - ANSWERSMust be 21 years of age
If you fail the written test you will not be permitted to Retest for - ANSWERS90 days
The following is an example of what type of Ceiling - ANSWERSStooped
A bean is defined as a structural or n...
FSDNY S98 Questions & Answers 100%
Correct!
Qualification for S98 certificate of fitness include all except - ANSWERSMust be 21
years of age
If you fail the written test you will not be permitted to Retest for - ANSWERS90 days
The following is an example of what type of Ceiling - ANSWERSStooped
A bean is defined as a structural or non structural solid member which could jacks down
into the rooms base more than _____ and is located more than _____ apart on center -
ANSWERSDown more than4" and 3' apart
The following are examples of line type detection except - ANSWERSionization smoke
detector
He could tonight a circuit to which automatic or manual initiating devices are connected
where the signal received does not identify the device operated is called? -
ANSWERSA signaling line circuit
Secondary power supplies are required to have sufficient power to operate the fire
alarm system in a non alarm condition for _______ hours and then be capable of
operating all notification devices for a minimum of ______ minutes - ANSWERS24
hours and 5 minutes
Secondary power supplies for emergency voice evacuation systems are required to
have sufficient power to operate the system in a non along condition for ______ hours
and kin be capable of operating the system during a fire or other emergency for a
minimum of ______ minutes - ANSWERS24 hours and 15 minutes under maximum
load
Secondary power supply shall automatically provide power to the protected premises
fire alarm system within _______ seconds when ever primary power fails to provide
minimum voltage required for proper operation? - ANSWERS10 seconds
Cording to NFPA chapter 4, batteries shall be permanently marked with what
information? - ANSWERSMonth and year of manufacture
NFPA 72 "record of completion" is prepared: - ANSWERSupon completion of
installation at just acceptance test
, According to NFPA chapter 4, the control panel charging apparatus shall be taken full of
recharging batteries within _____ _____ after batteries have been fully discharged? -
ANSWERS24 hours
According to the fire code of New York City, smoke detectors may be tested by the
following methods except for: - ANSWERSMeasured aerosol smoke introduced into the
detector
What type of drawing typically shows correct conductor counts? - ANSWERSRiser
diagrams
According to the fire code and fire rules, who is responsible for preventing unnecessary
and unwanted alarms? - ANSWERSOwner of a promise or a part thereof
I'll take you way and which according to NFPA chapter 4, a coded alarm signal shall
consist of not less than ______ complete rounds of the number transmitted. Each round
shall consist of not less than a ______ impulses - ANSWERS3 rounds and 3 impulses
According to the fire rules, who is responsible for making in trees in the smoke detector
maintenance log? - ANSWERSThe fire safety director or a person designated by
building owners if no FSD
According to NFPA chapter 4, installation Conductors shall be monitored for integrity.
The occurrence of a single open or single ground fault condition shall be automatically
indicated within ______ seconds - ANSWERS200 seconds
All of the following are good conductors of electricity except - ANSWERScarbon
Which of the following is an example of an initiating device? - ANSWERSSupervisory air
pressure switch and photo electric smoke detector
Into voice along and initiating device which is destroyed as a result of its operation is
what type? - ANSWERSNon restorable
It's the face of the nobleman equipment you shall be designed so that it is capable of
performing its intended function at ______ of its name plate voltage - ANSWERS85%
When installing heat detectors on ceilings, a row detector shall be located -
ANSWERSWithin 3' of the peak
The minimum distance for mounting of a spot type smoke detector from an air supply
diffuser is? - ANSWERS3' from diffusers
This is regarding manual fire alarm boxes, NFPA 72 requires that they be conspicuous,
unobstructed, and ________ - ANSWERSaccessible
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper papersmaster01. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €12,70. Je zit daarna nergens aan vast.