An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an - ans-Reversing valve
What is the difference between "demand defrost" and "timed defrost"? - ans-Demand defrost happens only when needed and timed def...
Heat Pump ESCO Exam Questions And Answers
An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an - ans-Reversing valve
What is the difference between "demand defrost" and "timed defrost"? - ans-Demand defrost happens only when needed and timed defrost is based on time/temperature.
The thermostat that controls the auxiliary electric heat according to the outdoor temperature is called the; - ans-Outdoor ambient thermostat
The outdoor temperature at which the heat pump provides the same amount of heat as the heat loss of the conditioned space without an auxiliary heat is known as the; - ans-Initial balance point
At what temperature is an outdoor ambient thermostat normally set? - ans-Slightly above the initial balance point.
The outdoor coil is frozen solid on a "no heat" service call. The most likely reason is; - ans-The outdoor fan is inoperative.
In order to determine a heat pumps' balance point, you must first calculate; - ans-The building's heat load.
When a heat pump is used for heating and cooling, the system is sized by the; - ans-Cooling load. A high efficiency heat pump system designed to function from high to low ambient conditions below 10*F, may have? - ans-Two outdoor coils with each one incorporating a dual stage compressor.
Room thermostats for heat pumps should be installed; - ans-As near to the main return air grill as possible.
When the heat pump compressor has malfunctioned, the customer has the option to switch the system into; - ans-Emergency heat mode.
Start up with a night set back digital thermostat requires the technician to always; - ans-Teach the customer how to program the thermostat.
The heat pump defrost board can be manipulated by the technician to; - ans-Simulate the defrost cycle.
The air-to-air heat pump outdoor unit is most efficient if located; - ans-In a moderate climate zone.
Which of the following are innovations that may be found on new high efficiency units? - ans-ECM fan motors.
How may a lockout (impedance) relay be reset? - ans-Simply disconnect power to the unit momentarily.
The temperature difference between the 1st and 2nd bulbs for heating on a heat pump thermostat is; - ans-Approximately 2*F
SEER is calculated by; - ans-Dividing the Btu's removed by the watts consumed during the cooling season.
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Prose1. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €10,69. Je zit daarna nergens aan vast.