BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM LATEST QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED 100% GUARANTEED PASS
6 keer bekeken 0 keer verkocht
Vak
BACKFLOW PREVENTION ASSEMBLY
Instelling
BACKFLOW PREVENTION ASSEMBLY
BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM LATEST QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED 100% GUARANTEED PASS
In responding to a backflow incident the water purveyor should
(A) Call the mayor
(B) Implement the emergency response plan
(C) Install a vacuum breaker
(D) Develop a ...
BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM
LATEST QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED
100% GUARANTEED PASS
In responding to a backflow incident the water purveyor should
(A) Call the mayor
(B) Implement the emergency response plan
(C) Install a vacuum breaker
(D) Develop a good excuse
Implement the emergency response plan
A mixture of air and gas is considered hazardous when the mixture exceeds what
percentage of gthe lower explosive limit
(A) 0%
(B) 3%
(C) 7%
(D) 10%
10%
To exert a pressure of 1.0 psi at base of a water column the column would have to
be
(A) 4.34 high
(B) 14.7 high
(C) 27.75 high
(D) 33.89 high
27.75 high
,A DC must be tested
(A) Upon installation
(B) Every 6 month
(C) Annually on a health hazard
(D) none of the above
Upon installation
An absolute perssure of 25 psiaa (at sea level) is equal to approximately
(A) 5 psi
(B) 10 psi
(C) 20 psi
(D) 25 psi
10 psi
Dueing a field test the air inlet on PVB must open at
(A) Above 2.0 psid
(B) Below 1.0 psid
(C) Above 1.0 psid
(D) Below 2.0 psid
Above 1.0 psid
A differential pressuer gauge is used to field test
(A) PVB's
(B) Dual Checks
(C) AVB's
(D) All the above
PVB's
Backflow in a water supply can be caused by
(A) Backpressure only
, (B) A Barometric Loop
(C) Backsiphonage only
(D) Backpressure and Backsiphonage
Backpressure and Backsiphonage
A BPAT tester is required to report test information on the proper forms to the
(A) Administrative authority
(B) Manufacturer's Rep
(C) EPA
(D) None of the above
Administrative authority
The relief valve opens when closing #2 shut off valve on a RP What is the most
probable cause
(A) #1 Shut off valve is open
(B) #2 Shut off valve is open
(C) #1 check is fouled open
(D) Shut off is leaking
#1 check is fouled open
When field testing the #1 Check of a RP the differential pressurw shouid be
(A) Greter than or equal to 5.0 psid
(B) 3.0 psid greater than the relief valve opening point
(C) 1.0 psid in the directiom of flow
(D) Less than 5.0 psid
Greter than or equal to 5.0 psid
When testing a SVB what is the firsrt test being performed
(A) The air inlet opening point
(B) The static pressure across the check valve
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper NurseAdvocate. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €8,78. Je zit daarna nergens aan vast.