The minimum blowdown for a spring loaded safety valve shall be of what percent of set pressure? - ANSWER>>10%
How is the main steam pressure gages tested? - ANSWER>>With an inspectors gage
Who is in charge...
nyc high pressure boiler license exam with questio
nyc high pressure boiler license exam
Geschreven voor
Nyc high pressure boiler license
Nyc high pressure boiler license
Verkoper
Volgen
winniewaweru
Ontvangen beoordelingen
Voorbeeld van de inhoud
Nyc high pressure boiler license exam with question and answers latest 2023 -2024 update The minimum blowdown for a spring loaded safety valve shall be of what percent of set pressure? - ANSWER>> 10% How is t he main steam pressure gages tested? - ANSWER>> With an inspectors gage Who is in charge of the code for any plumbing installations? - ANSWER>> The nyc plumbing code When will anchorage or guides be inspected? - ANSWER>> Annually How many brass washout plugs does a miniature boiler have? - ANSWER>> 3 brass washout plugs, 1" in size How often is HP piping expansion joints inspected? - ANSWER>> Weekly How long should a hydronic system be pressure tested for? - ANSWER>> 2 hours at no l ess than 100 psig How is a gage protected from excessive pressure? - ANSWER>> Shut off cock Who is authorized to witness a test on a gas piping system? - ANSWER>> Plumbing inspector, architect, licensed PE, master plumber, agency by the DOB How should a r emote disconnect be labeled? - ANSWER>> Remote control for burner When is a fusible plug not needed to be installed on a boiler? - ANSWER>> Over 200 psig When shall a power boiler with a MAWP over 400 be tested? - ANSWER>> Pressure tested annually What sha ll a design plan of a boiler and application contain but not limited to? - ANSWER>> Size, location, operating pressure + temperature of the pressure vessel and type + specs of PRV Who is responsible for maintaining the copies of the certified welder qualif ications report? - ANSWER>> The welding agency and shall be available to the DOB Who needs to furnish a control diagram and boiler operation instructions? - ANSWER>> The installer Who will certify and calibrate all gages utilized for testing? - ANSWER>> A testing operator What shall be placed in between different joints and piping material? - ANSWER>> An approved adapter fitting What items are exempt from the reporting requirements? - ANSWER>> The seal welds of the tubes and the installation of back rings to man holes and hand holes to boilers Who will be under control for any welding done to a high pressure tank? - ANSWER>> An engineer supervising a welding inspection agency acceptable to the DOB At what pressure is it requires to have extra heavy valves installed? - ANSWER>> 100 psig The ______ files an application for a boiler alteration? - ANSWER>> Inspector How many safety valves does a boiler have with over 500 square feet of heating surface? - ANSWER>> 2 Gas fired boilers not exceeding 100 square feet of heating surface shall be provided with a? - ANSWER>> Single or double cone type of hood diverter in the stack A heater for either liquid fuels or other liquids harmful to the boiler shall not be installed? - ANSWER>> Directly in the steam or water space within the boiler Who is responsible for any spatial relationship between tanks and gas services? - ANSWER>> The installer of the last installation to correct a violation a Who is responsible for the setting of operating and safety controls? - ANSWER>>The Installing Company With what safety fitting shall you protect high pressure steam and water boilers with? - ANSWER>>Dual low water cut outs Spring loaded safety valves have a total combined reli eve capacity of? - ANSWER>>100% of the max designed capacity of the boiler What is the total combined relieving capacity of power actuated relieving valves? - ANSWER>>No less the 10% of the MAWP or no higher then 20% above the MAWP What is the minimum bl owdown for a spring loaded safety valve? - ANSWER>>2% When a boiler is derated what changes? - ANSWER>>The MAWP decreases and the BTU output In hydronic piping systems where shall a shutoff valve be installed? - ANSWER>>Before and after the Pressure Redu cing Valve Hydronic piping joints between steel tubing and fittings shall be? - ANSWER>>Mechanical or Welded
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper winniewaweru. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €13,77. Je zit daarna nergens aan vast.