100% tevredenheidsgarantie Direct beschikbaar na betaling Zowel online als in PDF Je zit nergens aan vast
logo-home
CIC Practice Questions-Cleaning, Sterilization, Disinfection, Aspesis €7,77   In winkelwagen

Tentamen (uitwerkingen)

CIC Practice Questions-Cleaning, Sterilization, Disinfection, Aspesis

 0 keer bekeken  0 keer verkocht
  • Vak
  • Instelling

CIC Practice Questions-Cleaning, Sterilization, Disinfection, Aspesis

Voorbeeld 2 van de 8  pagina's

  • 13 juni 2024
  • 8
  • 2023/2024
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
avatar-seller
CIC Practice Questions-Cleaning,
Sterilization, Disinfection, Aspesis
A BI that was included in a load of surgical implantables has indicated a failure. You are
able to deduce that this was due to operator error, as this one load was not run on the
correct cycle. Which of the following actions should you take?
1. No action is needed as the implantables did go through a sterilizer cycle
2. The load with the positive BI must be reprocessed
3. A recall must be initiated; any loads of implantables run by the tech who ran this load
must be reprocessed
4. A recall must be initiated; any loads of implantables run by any tech must be
reprocessed - ANS-2. The load with the positive BI must be reprocessed

A tech in the OR has reported an infestation of fruit flies in the sterile instrument storage
room. The sterile packs were temporarily removed and pest management was called in
to eradicate the flies. The OR staff want to know whether they can use the sterile packs.
Which of the following is the best response?
1. The OR staff can use the packs without any reprocessing because there are no flies
visible on the outside of the packs
2. The OR staff can use the packs without any reprocessing if they open a test pack and
don't find any flies inside it
3. The OR staff don't need to repack the items but they do need to run the packs
through the sterilizer again
4. They need to completely reprocess all of the items that were in the affected room -
ANS-4. They need to completely reprocess all of the items that were in the affected
room

According to AAMI ST79. which of the following are among the recommendations for
testing of mechanical cleaning equipment in order to verify adequate cleaning?
a. Verification should be carried out monthly
b. Verification should be carried out upon installation
c. Verification should be carried out after major repairs
d. Verification should be carried out when changing cleaning chemistry

1. a, b, c, d
2. a, b, d
3. a, b, c
4. b, c, d - ANS-4. b, c, d

, b. Verification should be carried out upon installation
c. Verification should be carried out after major repairs
d. Verification should be carried out when changing cleaning chemistry

An OR team was using a unique surgical instrument on a patient and the instrument
was accidentally dropped on the floor. The team needs to reprocess it as quickly as
possible to finish the surgery and would like to use Immediate-Use Steam Sterilization
(IUSS). Which of the following is best recommended for this?
1. The team must clean and inspect the instrument before proceeding
2. The team can proceed with IUSS without prior cleaning and inspection of the
instrument since it will be used on the same patient
3. There is no need to use IUSS as the team can simply soak the instrument in 10%
bleach for 10 min
4. There is no situation in which IUSS is acceptable - ANS-1. The team must clean and
inspect the instrument before proceeding

Aseptic technique is defined as:
1. No touch technique
2. A process used in the OR
3. An absence of organisms
4. The process for keeping away disease producing organisms - ANS-4. The process
for keeping away disease producing organisms

During infection control rounds in the ED, the manager tells you that they will be doing
endovaginal ultrasounds soon and would like to use probe covers to speed up the
cleaning process. You inform the manager that:
1. Using a probe cover will eliminate the need to high level disinfect the probe
2. Using a probe cover will reduce the amount of time needed to clean the probe
3. Using a probe cover is acceptable, but high-level disinfection is still required
4. Using a probe cover is acceptable, but this device requires steam sterilization -
ANS-3. Using a probe cover is acceptable, but high-level disinfection is still required

In an effort to reduce cost and decrease turn around time, the endoscopy manager has
asked if the enzymatic detergent can be used for multiple patients. Your response is:
1. It is acceptable to reuse the detergent
2. The enzymatic detergent must be discarded after each use
3. There are no recommendations on reuse of the detergent
4. It is not necessary to use an enzymatic detergent for endoscopes - ANS-2. The
enzymatic detergent must be discarded after each use

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper modockochieng06. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €7,77. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 75759 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€7,77
  • (0)
  Kopen