The minimum amp circuit breaker that should be used to protect a 120V water heater circuit with a 1600 watt element would be rated at ________ amps.
15 amps
When testing for excessive EMF emission near a conductor or appliance, ...
the minimum amp circuit breaker that should be use
thr primary problem with using a series circuit to
the primary by product of excessive electrical r
Geschreven voor
Abyc
Abyc
Verkoper
Volgen
Dreamer252
Ontvangen beoordelingen
Voorbeeld van de inhoud
ABYC, Electrical Exam - Study Guide
Questions with Solutions
The minimum amp circuit breaker that should be used to protect a 120V water heater
circuit with a 1600 watt element would be rated at ________ amps. - answer15 amps
When testing for excessive EMF emission near a conductor or appliance, the tool of
choice is a(n) ____________ - answer Gauss Meter
Thr primary problem with using a series circuit to supply multiple loads is that? - answer
Voltage drop through the circuit will be excessive
The most common electrical circuit problem in marine applications is a(n)
____________ - answer unwanted open
The primary by-product of excessive electrical resistance is ___________ - answer heat
One horsepower is equal to ________ watts - answer746
Excessive electrical resistance can be caused by? - answer undersized wire, loose
connections, and corrosion
The tool of choice for tracing shorted and open circuits is the ________. – answer TDR
(Time Domain Reflectometer)
What material is recommended for clamping conductors over egines and moving
machinery? - answerMetal (w/ insulated inserts)
What is the acceptable minimum clearance for routing wire near a DRY exhaust
section? - answer9in (225mm)
The maximum number of terminals allowed to be attached to any one terminal stud is
______. - answer4
How much current should flow through the DC grounding conductor in a 25 amp DC
motor circuit? - answer0 amps (grounding conductor)
Where the ampacity of each individual conductor is sufficient to carry the entire load
current shared by the parallel conductors, the allowable size (and larger) is ____awg for
connecting parallel conductors. - answer8
, Running a cable to a DC panelboard (3% VD), 15' from the batteries (30' circuit), 12V
system with a max current of 90 amps. What is the cable gauge for this run? - answer0
AWG
DC grounded conductors on new boats that are also equipped with AC systems should
use __________ colored insulation. - answeryellow
The maximum spacing for cable run support is _____ - answer18 in (450mm)
The smallest wire gauge cable allowed for unsheathed wire runs through the boat is
___. - answer16 AWG
What degree F above ambient temperature indicates a "hot spot" in general. -
answer25F
Up to how many volts is considered acceptable with a neutral to ground leakage test? -
answer2V
What % voltage swing is considered normal with AC nominal voltage? - answer+/- 10%
How much simulated theoretical voltage drop is considered too much with a 15A load? -
answer15.5%
According to the ABYC, the shore-power grounded conductor should: - answerB. Not be
grounded onboard the boat
If a customer complains about receiving shocks from his/her boat when the boat is
plugged into shore power, the first test should be a: - answerA. polarity check of the
shore cord
If a customer complains of low voltage at the AC panel, the technician should first: -
answerB. check voltage at the dock pedestal
A costomer complains about a reverse polarity problem. All of the following are likely
causes except: - answerC. an open neutral
In a galvanic isolator installation, which of the following could cause a loss of galvanic
isolation? - answerD. all of the above
Tech A says that a generators neutral and ground must be tied together when the
generator is supplying AC power. Tech B says they must always be kept isolated.
Which tech is correct? - answerA. tech A
A dropped neutral conductor in a 240/120V shore power system will most likely show up
as: - answerD. burned out 120V appliances
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Dreamer252. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €12,79. Je zit daarna nergens aan vast.