1. Fire streams that deliver less than __________ GPM 350
are considered to be hand lines.
2. Using an in-line eductor, the back pressure must not 70 percent of the
exceed ________ pressure. inlet.
3. Fire streams greater that 350 GPM are considered to Master Streams.
be:
4. A test that is conducted using NFPA 1911 once a year Service/perfor-
is called a _______________ test. mance test.
5. Which best describes a dry hydrant? Found near lakes
or rivers.
6. Most fire fighting foam consists of approximately 94-99.9
_______ percent water.
7. The vacuum test requires a reading at the end of 5 10
minutes with no more than ________ inches of vacu-
um being lost.
8. Once the power take-off has been properly activated Slightly above 0
and the pump is engaged, the vehicle speedometer MPH
should show a speed of:
9. Indications of cavitation include: Rattling noise like
you're pumping
gravel.
10. A dual-pumping operation is: placing one
pumper at a hy-
drant and a sec-
ond pumper con-
nected intake to in-
take.
11. Improper tire pressure may cause: Poor handling
12.
1/8
, DPO Test A
_________ consists of a small return bypass water Around-the-pump
line connected from the discharge side of the pump proportioners
back to the intake side of the pump:
13. The nozzle reaction from a 1 1/4" tip at 50 PSI nozzle 123 LBS
pressure is approximately:
14. What is the desired pump pressure when supplying 2 137.5 PSI
lines of 2 1/2 hose, one 200' long and one 300' long,
each with a 250 GPM nozzle operating at 100 PSI?
15. The _________ enables apparatus to move and dis- Power Take Off
charge water at the same time: (PTO)
16. The purpose of an inverter on an apparatus is to trans- DC current into AC
form: current (DC-NJ)
17. Before an apparatus response from the station, the Ensure that every-
driver/operator should: one is seated and
belted.
18. When pumping to a standpipe system, a pump opera- 25 PSI
tor should allow ______ friction loss for the standpipe
system.
19. Which foam has excellent heat stability and burn back Protein foam
resistance?
20. In-line relay valves allow for: late-arriving
pumpers to hook
up without
interrupting
operations.
21. A sudden stoppage of water moving through a hose Water hammer
or pipe may result in:
22. Which is a fire hose appliance carried on a fire appa- Gated wye
ratus?
2/8
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Arrjun. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €10,43. Je zit daarna nergens aan vast.