The phantom pictured below contains only water. Based on the ROI readings what problem should be
reported to the medical physicist? - correct answer ✔✔Unacceptable uniformity



What artifact is visible in the image below in the posterior portion of the patient's abdomen? - correct
answer ✔✔Beam hardening artifact



What CT artifacts are demonstrated in this image? - correct answer ✔✔Beam hardening artifact

Ring artifact



A technologist review a patient's EMR for evidence of a gadolinium allergy prior to performing a scan
with contrast. is this a hippa violation? - correct answer ✔✔This is NOT a hippa violation



Compared to a pitch of 1.2, a pitch of 1 will result in

1. Increased dose

2. increased spatial resoluation

3. increased total scan time - correct answer ✔✔Increased dose

Increased spatial resolution



Which part of the PACS system houses all of the historic digital image data along with the current digital
data being generated by the modalities? - correct answer ✔✔Archive server



Consider a PACS network running through a traditional internet network. What is the primary advantage
of this network architecture? - correct answer ✔✔The PACS archive server can be accessed from any
internet-connected computer



What difference in image processing accounts for the visible difference between these two images of the
brain? - correct answer ✔✔Back projection filter

,During spiral scaling attenuation data from the patient is first organized in a helical pattern. the process
of converting this information into axial sections is accompanied by through: - correct answer
✔✔interpolation



Matrix size in CT refers to: - correct answer ✔✔The number of pixels in the matrix



Consider a CT image that was initially displayed with a 300 WW and a 30 WL. DECREASING the WL from
30 to 0 will have what effect on the image? - correct answer ✔✔decreased brightness



If the pitch is greater than one, this results in: - correct answer ✔✔Missing view in the scan data



The contrast resolution of a CT system is recorded with which of these units? - correct answer ✔✔HU



Compared to a pitch of 1, a pitch of 1.137 will have



1. decreased scan time

2. decreased pt. dose

3. decreased spatial resolution - correct answer ✔✔1. decreased scan time

2. decreased pt. dose

3. decreased spatial resolution



The main DISADVANTAGE of using thick detector rows is - correct answer ✔✔decreased contrast
reolution



ideally, the patient worklists on imaging equipment should be automatically populated from examination
request placed though the: - correct answer ✔✔Electronic medical record ( EMR)



After completing a routine scan of the chest the radiologist request a sagittal image series with 5mm
slices. this request can be completed using which of these imaging techniques? - correct answer
✔✔multiplaner reformation

, What is the principle function of the data acquisition system (DAS) in CT? - correct answer
✔✔Reconstruct raw data into image data



This image shows excessively high contrast. Improving the contrast could be accomplished by: - correct
answer ✔✔Increasing the WW



Cone beam artifact is increased under what circumstances? - correct answer ✔✔Use a wide X-ray beam



A protocol designed for viewing boney injures to the thorax should use what kind of reconstruction
algorithm? - correct answer ✔✔Edge enhancing algorithms



Compared to a 2mm reconstruction slice thickness a 1mm slice thickness will result in

1. decreased image noise

2. decreased spatial resolution

3. more total image slices - correct answer ✔✔more total image slices



Which of the following is a disadvantage of accessing the PACS server through the internet on a basic
desktop computer

1. decreased image quality

2. inability to access archived studies

3. increased archived retrieves time - correct answer ✔✔decreased image quality



Ring artifact can be the result of - correct answer ✔✔using a large display field of view



The physical size of the X-ray beam is controlled by: - correct answer ✔✔Pre patient collimators



Which of these images is displayed with a WW of 2500 and WL of 600? - correct answer ✔✔image b

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Sakayobako30. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €17,06. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 85443 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€17,06
  • (0)
  Kopen