Answers to Common Questions About Safety of CT Scans
The radiation dose to the patient during a
CT scan is - CORRECT ANSWER - CTDI
Contact shields are made of _______________ and selectively protect organs that lie within the scanned
region during a CT scan. - CORRECT ANSWER - Bismuth
Which ...
Answers to Common Questions About Safety of CT Scans
The radiation dose to the patient during a
CT scan is - CORRECT ANSWER - CTDI
Contact shields are made of _______________ and selectively protect organs that lie within the scanned
region during a CT scan. - CORRECT ANSWER - Bismuth
Which technical factor has a direct effect on patient dose? - CORRECT ANSWER - MAs
A device used to measure the patient dose from a CT exam is - CORRECT ANSWER - Ionization chamber
To meet current industry standards for required dose reduction measures, a CT system must employ
which of the following?
1. Automatic exposure control (AEC)
2. Adult and pediatric protocols
3. Digital imaging and communications in medicine (DICOM) radiation dose structured reporting (RDSR) -
CORRECT ANSWER - 1, 2, & 3
When scanning a pediatric patient, what technical factor should be adjusted - CORRECT ANSWER - Tube
milliamperage (mAs)
Whole body risk based upon the radio sensitivity of exposed tissues may be estimated using the unit: -
CORRECT ANSWER - Effective dose
CTDI stands for - CORRECT ANSWER - CT dose index
The use of iterative reconstruction techniques for CT data processing results in
, 1. Decreased noise on the reconstructed image
2. Decreased radiation dose to the patient
3. Decreased image reconstruction time. - CORRECT ANSWER - 1 and 2 only
Which of the following methods may be employed to reduce the radiation dose to the pediatric patient
undergoing CT?
1. Reduce mA
2. Limit phases of acquisition
3. Increase pitch - CORRECT ANSWER - 1, 2 and 3
A decrease in the focus to detector distance of a multi detector CT system would result in - CORRECT
ANSWER - Increased patient dose
The radiation dose index calculation that takes into account the variations in absorption across the field
of view due to beam hardening is termed - CORRECT ANSWER - CTDIw
The radiation dose structured report (RDSR) must include which of the following details regarding a CT
acquisition
The reduction in intensity of the CT x-ray beam as it passes through patient tissue may be generally
termed - CORRECT ANSWER - Attenuation
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Smartdove. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €8,88. Je zit daarna nergens aan vast.