Cooling Correct Answer-Heat Exchangers Shall Be Checked For _____ Water Flow. Off Correct Answer-All Alarm Pilot Lights Should Be In What State? Ventilating Louvers Are Free To Operate & Heat Is Adequate, Not Less Than 40 Degrees F For Diesel Pump Rooms Correct Answer-There Are 2 Requirements...

[Meer zien]

Voorbeeld 3 van de 16  pagina's

  • 16 augustus 2024
  • 16
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • Cal. Fire Firepump
  • Cal. Fire Firepump
avatar-seller
Fire pump Exam preparation Questions with Correct
Answers
1. The purpose of inspection shall be to verify that the pump assembly
Correct Answer-Appears to be condition and is free from physical
damage


2.The 5 pertinent visual observations specified in the NFPA 25 checklist
that shall be performed weekly are Correct Answer-1 Pump house
condition 2 pump system conditions 3 electrical system conditions
Diesel engine system conditions 5 steam system conditions


3.Part of the check of the pump house conditions is that : Correct
Answer-ventilating louvers are free to operate


4. During the weekly inspection the pump suction discharge and bypass
valves should be observed to be : Correct Answer-OB fully open


05. During the weekly inspection , the suction reservoir should be
observed to be : Correct Answer-A full


6. As observed during the weekly inspections wet pit suction screens
should be Correct Answer-Unobstructed and in place


7. During the weekly inspection of the pump assembly the controller
pilot light should be Correct Answer-Illuminated (power on)

,8. During the weekly inspection of the pump assembly the transfer
switch normal pilot light should be Correct Answer-Illuminated (power
on)


9 During the weekly inspection of the pump assembly the isolating
switch should be observed to be Correct Answer-Closed


10 During the weekly inspection of the pump assembly the reverse phase
alarm pilot light should be observed to be Correct Answer-Off


11. During the weekly inspection of the pump assembly the normal
phase rotation pilot light should be observed to be Correct Answer-On


12, during the weekly inspection of the pump assembly the oil level in
the vertical motor sight glass should be observed to be Correct Answer-
Normal


13.During the weekly inspection of the pump assembly the fuel tank
should be observed to be Correct Answer-Two-thirds full


14.during the weekly inspection of the pump assembly the controller
selector switch should be in ___________ position Correct Answer-
Auto


15. During the weekly inspection of the pump assembly all alarm pilot
lights should be Correct Answer-Off

, 16.During the weekly inspection of the pump assembly the engine
running________ meter is reading Correct Answer-Time


17. During the weekly inspection of the pump assembly the oil level in
the ______gear drive should be normal Correct Answer-Right angle


18. During the weekly inspection of the pump assembly the electrolyte
level in batteries should read Correct Answer-Normal


19. A weekly test of the fire pump assemblies shall be conducted Correct
Answer-Without flowing water


20. The pump test shall be conducted by starting the pump automatically
Correct Answer-True


21. A weekly test of the fire pump assembly shall be conducted by
starting the pump without flowing water. The electric pump shall be run
a minimum of. Correct Answer-10 minutes


22. A weekly test of the fire pumps assembly shall be conducted by
starting the pump without flowing water. The diesel pump shall run a
minimum of. Correct Answer-30 minutes


23. During the weekly test of the fire pump assemblies, an installed
safety relief valve shall. Correct Answer-Permit water to flow

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper cracker. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €14,72. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 66579 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€14,72  1x  verkocht
  • (0)
  Kopen