100% tevredenheidsgarantie Direct beschikbaar na betaling Zowel online als in PDF Je zit nergens aan vast
logo-home
ARRT CT REGISTRY PHYSICS || 100% SOLVED SOLUTIONS!! €25,12   In winkelwagen

Tentamen (uitwerkingen)

ARRT CT REGISTRY PHYSICS || 100% SOLVED SOLUTIONS!!

 7 keer bekeken  0 keer verkocht
  • Vak
  • ARRT CT REGISTRY PHYSICS
  • Instelling
  • ARRT CT REGISTRY PHYSICS

The main advantages of CT over conventional radiography are correct answers -Elimination of superimposed structures - the ability to differentiate small differences in density of an atomic structures - superior quality of the images Computer tomography for technologists exam review Romans chapte...

[Meer zien]

Voorbeeld 4 van de 68  pagina's

  • 20 augustus 2024
  • 68
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • ARRT CT REGISTRY PHYSICS
  • ARRT CT REGISTRY PHYSICS
avatar-seller
ARRT CT REGISTRY PHYSICS || 100% SOLVED
SOLUTIONS!!
The main advantages of CT over conventional radiography are correct answers -Elimination
of superimposed structures
- the ability to differentiate small differences in density of an atomic structures
- superior quality of the images
Computer tomography for technologists exam review Romans chapter 1 page 3

CT image quality is evaluated using a number of criteria including correct answers - spatial
resolution
- low contrast resolution
- temporal resolution

Computer tomography for technologists exam review Romans chapter 1 page 3

This type of resolution choice refers to acquisition speed correct answers Temporal resolution

Computer tomography for technologists exam review Romans chapter 1 page 3

What is the controlling factor of temporal resolution correct answers -gantry rotation speed
-reconstruction method

This term offers the ability to freeze motion and provide blur free images correct answers
Temporal resolution

https://coursewareobjects.elsevier.com/objects/elr/DeMaio/CT2e/computedtomography/
index.htm

Which of the following technical adjustments may be employed to improve temporal
resolution of an MDCT system correct answers decrease scan time

https://coursewareobjects.elsevier.com/objects/elr/DeMaio/CT2e/computedtomography/
index.htm

The CT process creates what type of images with information collected when an x-ray beam
passes through an area of anatomy correct answers Cross-sectional images


Computer tomography for technologists exam review Romans chapter 1 page 3

The CT slice represents a specific plane in the patient's body referred to as correct answers
The z-axis

Computer tomography for technologists exam review Romans chapter 1 page 3

What axis determines the thickness of the cross-sectional slice correct answers The z-axis

Computer tomography for technologists exam review Romans chapter 1 page 3

,The dimensions of a voxel can be calculated as a product of correct answers -pixel size
-section width

https://coursewareobjects.elsevier.com/objects/elr/DeMaio/CT2e/computedtomography/
index.htm

If the Z element or Z axis is taken into account the result is a cube referred to as a correct
answers Voxel

Computer tomography for technologists exam review Romans chapter 1 page 3

The voxels dimension may be decreased by which of the following? correct answers
Decreasing the selection width

Online exam Mosby

What term of a CT image controls the length of the voxel correct answers Section width

Online exam Mosby

The dimensions of a voxel may also be reduced through decreases in the ______ correct
answers -size of the pixels


Online exam Mosby

Data that form the CT slice are further section into correct answers Elements

Computer tomography for technologists exam review Romans chapter 1 page 3

These elements can consist of two dimensional squares in which the width is indicated by X
and the height is indicated by Y.... what is the name of the term correct answers Pixel

Computer tomography for technologists exam review Romans chapter 1 page 3

What is the term that is a grid formed from rows and columns of pixels correct answers
Matrix

Computer tomography for technologists exam review Romans chapter 1 page 3

The Xray photons pass through or are absorbed or scattered by structures and varying
amounts depending on correct answers - average photon energy of the x-ray beam
- characteristic of the structure in its path


Computer tomography for technologists exam review Romans chapter 1 page 3

The degree in which an x-ray beam is reduced is referred to as correct answers Attenuation

,Computer tomography for technologists exam review Romans chapter 1 page 3

Objects that have little ability to attenuate the beam are said to have what type of attenuation
correct answers Low attenuation
Computer tomography for technologists exam review Romans chapter 1 page 3

Objects that have the ability to absorb much, or all, of the beam said to have what type of
attenuation correct answers High attenuation
Computer tomography for technologists exam review Romans chapter 1 page 3

Lower attenuation structures are represented by what color correct answers Black or dark
grey area on the image

Computer tomography for technologists exam review Romans chapter 1 page 3

Higher attenuation structures are represented by what color correct answers White or light
gray area on the image

Computer tomography for technologists exam review Romans chapter 1 page 3

The number of photons that interact with an object depends on correct answers - thickness
- density
- atomic number of the object
Computer tomography for technologists exam review Romans chapter 1 page 3

The amount of Xray beam that is scattered or absorbed per unit thickness of the absorber is
expressed by the term correct answers Linear coefficient


Computer tomography for technologists exam review Romans chapter 1 page 3

Differences and linear coefficient amount issues are responsible for correct answers x-ray
image contrast


Computer tomography for technologists exam review Romans chapter 1 page 3

To differentiate an object on a CT image from adjacent objects there must be correct answers
There must be sufficient density differences between the two objects

Computer tomography for technologists exam review Romans chapter 1 page 3

The administration of what is often used to create a temporary artificial density difference
between objects correct answers Oral or intravenous administration of a contrast agent

Computer tomography for technologists exam review Romans chapter 1 page 3

________ agents flll certain structures with a higher density material, subsequently raising
the structures ability to attenuate that Xray beam. correct answers Oral or intravenous
iodinated

, Computer tomography for technologists exam review Romans chapter 1 page 149

It is important to note that the contrast agent does not change the body tissues but only
resides in them

True or false correct answers True


Computer tomography for technologists exam review Romans chapter 1 page 149

An -HU-hounsfield derived from a ______ can be useful in some instances, particularly when
a quick check of a density is needed correct answers single pixel



Computer tomography for technologists exam review Romans chapter 1 page 15

What hounsfield values are in the naturally occurring range and are not man made objects
like surgical clips? correct answers -1,000 to 1000



Computer tomography for technologists exam review Romans chapter 1 page 15

What is the term that is used to qualified the degree that the structure attenuates an Xray
beam correct answers Hounsfield unit

Computer tomography for technologists exam review Romans chapter 1 page 3

There are more than ______ Hounsfield unit while the monitor can only display _______
shades of gray. Furthermore the human eye can different shade only a fraction of those
shades correct answers -2000 Hounsfield unit
-256 shades of gray




Computer tomography for technologists exam review Romans chapter 1 page 14

the _______ of an object can provide valuable diagnostic information. correct answers
Hounsfield measurement
Computer tomography for technologists exam review Romans chapter 1 page 15

Because measurement may be negatively affected by ________, caution should be used
when. HU values are used in the diagnosis of disease correct answers volume averaging for
image noise

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper ProPerfomer. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €25,12. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 81849 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€25,12
  • (0)
  Kopen