100% tevredenheidsgarantie Direct beschikbaar na betaling Zowel online als in PDF Je zit nergens aan vast
logo-home
MRI IN PRACTICE FINAL EXAM ACCOMPANEID WITH VERIFIED QUESTIONS & ANSWERS.. €9,89   In winkelwagen

Tentamen (uitwerkingen)

MRI IN PRACTICE FINAL EXAM ACCOMPANEID WITH VERIFIED QUESTIONS & ANSWERS..

 0 keer bekeken  0 keer verkocht
  • Vak
  • MRI IN
  • Instelling
  • MRI IN

MRI IN PRACTICE FINAL EXAM ACCOMPANEID WITH VERIFIED QUESTIONS & ANSWERS.. Resonance - CORRECT ANSWER --A phenomenon that occurs when two objects naturally vibrate at the same frequency. Results of resonance - CORRECT ANSWER --The direction of the NVM shifts as they transition to high ener...

[Meer zien]

Voorbeeld 2 van de 9  pagina's

  • 23 augustus 2024
  • 9
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • MRI IN
  • MRI IN
avatar-seller
MRI IN PRACTICE FINAL EXAM
ACCOMPANEID WITH VERIFIED QUESTIONS
& ANSWERS..
Resonance - CORRECT ANSWER --A phenomenon that occurs when two objects
naturally vibrate at the same frequency.

Results of resonance - CORRECT ANSWER --The direction of the NVM shifts as
they transition to high energy. Away from Bo
The angle to which the NMV moves out of alignment with the Bo is called FLIP
ANGLE

Effect of RF Pulse - CORRECT ANSWER --1)hydrogen protons absorbs the RF
energy
2)increases the # of spin down hydrogen nuclei
SPIN UP NUCLEI GAIN ENERGY THROUGH RESONANCE

Flip angle - CORRECT ANSWER --the angle to which the longitudinal magnetization
is tipped into the transverse plane, following the initial RF excitation pulse

Faraday's Law - CORRECT ANSWER --When a conductive receiver coil is placed in
the area of a moving magnetic field, a voltage is induced in it.
Resonance causes protons to precession in phase in the transverse plane, this
generates an electric current.
The MR signal is produced when when in-phase magnetization cuts across the coil.

Magnitude of MR signal - CORRECT ANSWER --Depends on the amount of
magnetization present in the transverse plane
-Small magnetization transverse plane=LOW SIGNAL {Hypo-intense, DARK}
-Large magnetization=HIGH SIGNAL {hyper-intense, BRIGHT}

relaxation - CORRECT ANSWER --The process by which hydrogen transition back
to low energy state.
When the RF pulse is removed the NMV, the NMV is influenced by Bo:
1.The protons move out of phase (dephase) with each other causing the transverse
magnetization to slowly disappear.
2.Protons return to lower energy level (relax) to the resting state of net longitudinal
magnetization (Mz)

Free Induction Decay Signal (FID) - CORRECT ANSWER --The loss of
signal/voltage
As the transverse magnetization decreases, so does the magnitude induced in the
receiver coil.
This occurs by the inhomogeneities, causing the protons to lose coherency
(deodars)

pulse sequence - CORRECT ANSWER --a series of RF pulses, gradient applications
and intervening time periods

, Dramatically impacts the appearance of a MRI image
MRI obtain various contrast images using pulse sequence.
All help to visualize different anatomy and pathology

pulse timing parameters - CORRECT ANSWER --a. A sequence of transmitting rf
pulses during precise times with interviening periods of recovery.
Repetition Time (TR)
Echo Time (TE)

Echo Time (TE) - CORRECT ANSWER --Time in milliseconds from the application of
the RF pulse to the peak of the signal induced in the coil. TE determines how much
decay of transverse magnetization is allowed to occur

Intrinsic Contrast Parameters - CORRECT ANSWER --those parameters that cannot
be changed because they are inherent to the body's tissues
T1 recovery time
T2 Decay Time
Proton density
Flow
Apparent diffusion coefficient (ADC)

Extrinsic Contrast Parameters - CORRECT ANSWER --those parameters that can
be changed at the operator console
Repetition time (TR)
Echo time (TE)
Flip angle
Inversion Time (TI)
Turbo factor or echo train Length (ETL)

T1 RECOVERY (SPIN LATTICE RELAXATION) - CORRECT ANSWER --Recovery
of longitudinal magnetization
(Gradually INCREASES).
Time it takes the protons to recover 63% of its longitudinal magnetization
Involves the nuclei giving up their energy to the surrounding environment
Occurs at different rates in different tissues

Repetition Time (TR) - CORRECT ANSWER --time between each excitation pulse

T2 Decay (Spin spin relaxation) - CORRECT ANSWER --loss of transverse
magnetization as a result of spin-spin relaxation
Interactions between neighboring nuclei cause dephasing (energy loss)
Involves loss of phase coherence

T2 Decay Time - CORRECT ANSWER --The time it takes 63% of the transverse
magnetization to dephase (37% in-phase) in a tissue.
The rate of decay is also an exponential process & occurs in different tissues.

T2* Decay - CORRECT ANSWER --Caused by the immediate deplaning of spins in
the transverse Mxy plane once the RF pulse is turned off.
Detected by receiver coil immediately after the termination of the RF pulse.

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper reagandave. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €9,89. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 83637 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€9,89
  • (0)
  Kopen