The lowest acceptable fuel gauge reading on a fire apparatus during inspection is:
at least 3/4-full.
The rescue tool supply system equivalent of a junction box is called:
a manifold
3 conditions where you should drive your fire a...
d o pumper cdc ccre questions and answers graded a
the lowest acceptable fuel gauge reading on a fire
3 conditions where you should drive your fire appa
three conditions to wearing your seat belt befo
Geschreven voor
FIRE APPARATUS DRIVER/OPERATOR - PUMPER
FIRE APPARATUS DRIVER/OPERATOR - PUMPER
Verkoper
Volgen
julianah420
Ontvangen beoordelingen
Voorbeeld van de inhoud
D-O Pumper CDC CCRE QUESTIONS
AND ANSWERS GRADED A+
The lowest acceptable fuel gauge reading on a fire apparatus during inspection is: -
answerat least 3/4-full.
The rescue tool supply system equivalent of a junction box is called: - answera manifold
3 conditions where you should drive your fire apparatus in low gear: - answer1.
Approaching an intersection
2. Travelling around a corner
3. Climbing a hill
Three conditions to wearing your seat belt before an emergency vehicle moves: -
answer1. Providing patient care in the back of an ambulance.
2. Performing training for personnel learning to drive the tiller portion of a tractor draw
aerial apparatus.
3. Loading the hose back onto the fire apparatus.
if you are driving a fire apparatus that is longer than you are familiar with you must: -
answerAre more caution when judging clearance so you don't run up on curbs and
corners.
NFPA Standard 1002 requires that driver/operators operate a fire apparatus over a
predetermined route on a public roadway that incorporates all of the following EXCEPT :
- answerBoth a left and a right curve.
If a 3-inch hose is flowing 150 GPM, and a 2-inch hose is flowing at 150 GPM, which is
flowing at the higher velocity? - answerThe 2-inch is flowing at a higher velocity.
One of the principles of pressure says that the pressure on an amount of water... -
answer... is always perpendicular to any of any surface it acts on.
To raise the temperature of one lb. of water from 100F to 212F takes how many BTUs?
- answer112 BTUs
What are BTUs? - answerBritish Thermal Unit.
One BTU is equal to the amount of energy used to raise the temperature of one pound
of water one degree Fahrenheit. +1 degree Fahrenheit = 1 BTU.
, The master stream device that is often called a deck gun is the.. - answer...turret pipe
device.
BOUNCING water off the INSIDE WALL of the nozzle bore to create a fog pattern is
called? - answerPeriphery deflection
Periphery means side(like a wall is the side of a room)
Deflection means bounce.
A pumper has two 300-foot sections of a 3-inch hose with 2 1/2inch-couplings. They are
siamesed into 200 feet of 5-inch attack line.The attack line ends in a master stream with
a flow of 350 GPM. Given this hose layout, determine the total pressure loss for this
hose assembly. - answer44 PSI
"C" in the formula FL = C Q² L represents what? - answerHose Diameter Coefficient.
Determine the TPL for a hose assembly in which 400 feet of 5-inch hose is wyed into a
one 200-foot section of 2 1/2-inch hose and one 300-foot section of 2 1/2 inch hose.
Each attack hose is flowing at 200 GPM. - answer39 PSI
Most flowmeters in use have a design based on: - answera spring probe
(Note) A Municipal storm drain is not a water source - answer(Note) A Municipal storm
drain is not a water source
Name TWO correct statements about looping mains in a distribution grid. - answer1.
They create constant flow and less sediment forms in the pipes.
2. They ensure that water flows from two directions.
In a relay operation, relay pumpers must set their intake pressure relief valves (if
available) at: - answer10 psi ABOVE the discharge pressure of a previous pumper.
One of the assumptions of a maximum distance relay method is that: - answerThere is
20 PSI of residual pressure at each relay pumper.
State 2 characteristics of a forward lay. - answer1. A four-way hydrant valve is often
used with this lay.
2. Allows driver/operator to monitor the fire scene
1. fourway
2. d/o monitor fire scene.
State 3 characteristics of a reverse lay. - answer1. Forces the fire personnel to unload
equipment before hooking up to the hydrant.
2. Keeps pumper at the hydrant.
3. Pumper moves away from the fire incident to the hydrant
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper julianah420. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €17,50. Je zit daarna nergens aan vast.