Solutions Manual for Electrical Wiring Commercial
18th Edition by Phil Simmons A+

Solution and Answer Guide
SIMMONS/ODE, ELECTRICAL WIRING COMMERCIAL, 18E © 2024, 9780357767115;
CHAPTER 1:COMMERCIAL BUILDING PLANS AND SPECIFICATIONS


TABLE OF CONTENTS
Review .......................................................................................................................................................... 1



Note to instructor: It is recommended that students be required to respond, where
appropriate, with answers that are complete sentences.


REVIEW

Refer to the National Electrical Code or the working drawings when necessary. Where
applicable, responses should be written in complete sentences.
1. What section of a commercial building’s specification contains a list of contract
documents?
Answer: A list of the contract documents is contained in General Clauses and Conditions. A
listing of the Commercial Building contract documents is presented in this chapter under the
heading “Commercial Building Plans.” The instructor may wish to have the students check over
this listing and compare it with the plans provided.
2. The requirement for temporary light and power at the job site will be found in what
portion of a commercial building’s specification?
Answer: The Supplementary General Conditions specifies the job site requirements for
temporary light and power. In some contracts, this electrical system becomes the responsibility
of the general contractor; in other contracts, it is the electrical contractor’s responsibility to
install and maintain the temporary electrical system. The instructor may wish to refer the student
to NEC Article 590 and discuss the requirements in detail.


A+ Page 1

,Created By: A Solution




3. The electrician uses the Schedule of Working Drawings for what purpose?
Answer: The electrician uses the Schedule of Working Drawings to determine whether all of the
drawings are at hand. The information on “the other sheets” may be very important, especially in
coordinating with other contractors.
4. Complete the following items by indicating the letter(s) designating the correct source(s)
of information:
No. Answer Item Information

4. Sections Ceiling height Sections, Sheet A6

5. Electrical Electrical receptacle Electrical symbol schedule, Chapter
symbol style 2,Figure 2–6
schedule

6. Electrical Electrical outlet Electrical layout drawings, Sheets
layout location El,E2, and E3
drawings

7. Elevations Exterior wall finishes Elevations, Sheets A4 and A5

8. Site plan Grading elevations Site plan, Sheet A4

9. Electrical Panelboard schedules Electrical layout drawings, Sheet E4
layout
drawings

10. Architectural Room width Architectural floor plan, Sheets Al,
floor plan A2,and A3

11. Architectural Swing of door Architectural floor plan, Sheets Al,
floor plan A2,and A3

12. Sections View of interior wall Sections, Sheet A6



A+ Page 2

,Created By: A Solution


Match the items on the left with those on the right by writing the letter
designation ofthe appropriate organization from the list on the right.


13. NEC Electrical Code National Electrical Code (NEC)

14. IAEI Electrical inspectors International Association of
ElectricalInspectors (IAEI)


15. NFPA Fire codes National Fire Protection Association
(NFPA)

16. IESNA Lighting information Illuminating Engineering
Society ofNorth America
(IESNA)

17. UL Listing service Underwriters Laboratories, Inc.
(UL)

18. NEMA Manufacturers’ National Electrical
standards ManufacturersAssociation
(NEMA)

19. PE Seal Professional Engineer (PE)


Match the items on the left with those on the right by writing the letter
designation ofthe proper level of NEC interpretation from the list on the
right.


20. with Allowed by the Code Shall be permitted, or Shall not
special berequired, NEC
permission

21. with May be done Shall be permitted, or Shall not



A+ Page 3

, Created By: A Solution


special berequired, NEC
permission

22. shall Must be done Shall, National Electrical Code

23. shall Required by the Code Shall, National Electrical Code

24. never Up to the electrician Shall be permitted, or Shall not
berequired, NEC
25. Find NEC 250.52(A)(5) and record the first four words.

Answer: The first four words of NEC 250.52(A)(5) are Rod and pipe electrodes.

Show required conversion calculations for problem 26 and problem 27.

26. Luminaire style F is four feet long. The length in SI units, as specified by the NEC, is

Answer: The length in SI units is 1.22 m; 4 ft × 0.3048 m/ft = 1.2192 m. As will be discussed
later, this luminaire is now called a 4 by 2 or the equivalent 1200 by 600 in metric terms. This
question assumes that the luminaire is exactly 4 ft long.

27. The gross area of the drugstore basement is 1395 square feet. The area in square meters is

Answer: The area in SI units is 129.7 sq. m; 1395 sq. ft × 0.093 sq. m/sq. ft = 129.7 sq. m.




To answer Questions 28–31, refer to the Plans included with this book. Determine the Following
dimensions. Write the dimensions using unit names, not symbols (for example, 1 foot, not 1’),
and indicate the source of the information.

28. What is the inside clear distance of the interior stairway to the drugstore basement?

Answer: The inside clear distance of the interior stairway to the Drugstore basement is 4 ft 0 in.
(1.22 m), as scaled from Sheet A2.

29. What is the gross square footage of each floor of the building?

Answer: The gross area of each floor of the building is 60 ft × 43 ft = 2580 sq. ft (18.82 m ×
13.1 m = 246.5 sq. m), as taken from Sheets Al, A2, and A3.

30. What is the distance in the drugstore from the exterior block wall to the block wall
separating the drugstore from the bakery?

A+ Page 4

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper ASolution. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €12,68. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 64438 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen

Laatst bekeken door jou


€12,68  1x  verkocht
  • (1)
  Kopen