NFPA established what - Answer-life safety codes
NFPA revises life safety codes every - Answer-3 years
Life safety codes - Answer-establishes regulations that govern all aspects of the
building structure
Deficiencies in the life safety codes are cited what - Answer-K-tags
Follow what edition of the NFPA - Answer-2012
Doors - Answer--must open outward (egress)
-must be lighted by exit signs
-only can lock from the outside
Fire doors - Answer--required in all corridors
-must have automatic hold open devices activated by the fire alarm
Locks - Answer-can only be on resident rooms if they can be opened from the outside
Fire alarms - Answer--both flashing and audible alarms
-connected to emergency power
Smoke detectors - Answer-must be hardwired and connect to emergency power
Smoking - Answer--not in any room
-hazardous location should have no smoking signs
-ashtrays shall be provided in smoking allowed areas
Hand sanitizer - Answer--placed in a corridor, the corridor must have a minimum width
of 6 feet
-dispensers can only be placed in areas with smoke detectors when on carpet
-cannot be placed 1 inch within an ignition source
American standards institute (ANSI) - Answer-established standards for making public
buildings accessible for those with disabilities.
Must decided to use ANSI or ADAAG (americans with disabilities act accessibility
guidelines) - Answer-
, Gratings - Answer-spaces no greater than 1/2 inch
Parking spaces are how wide - Answer-13 feet. 8 ft for vehicle, 5 feet for an aisle
Ramp - Answer--slope > 1"-20" is considered a ramp
-maximum rise of a ramp is 30 inches
-maximum slope 1" to 12"
Water fountain - Answer--no more than 36 inches off the floor
-flow must be at least 4 inches
Telephone chord length - Answer-29 inches
Grab bars - Answer-33 to 36 inches from floor
Toilet seat - Answer-17 to 19 inches from floor
Handraisl - Answer-30 to 34 inches from ground or stair tread
Thresholds (bottom part of door) - Answer-no more than 1/2 inch high and 3/4 on sliding
doors
Room size - Answer-80 square ft for double
100 square ft for single
Window sill - Answer-cant be more than 36 inches high
Floors - Answer-resident rooms must be at or above ground level
Call light - Answer-must always reach the bed
Sufficient space - Answer-enough space to provide services
No federal requirements for nursing stations - Answer-
Dining and activities room - Answer--must be well lighted
-must be well ventilated
-adequately furnished
-large enough to accommodate activities
Well-lighted areas means - Answer-enough lighting for a resident to perform a task
Well ventilated means - Answer-good air circulation without floor drafts. All vents must
vent to the outside
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper biggdreamer. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €12,00. Je zit daarna nergens aan vast.