100% tevredenheidsgarantie Direct beschikbaar na betaling Zowel online als in PDF Je zit nergens aan vast
logo-home
CT Registry Review Program Post-Test Questions and Answers Graded A+ €13,25   In winkelwagen

Tentamen (uitwerkingen)

CT Registry Review Program Post-Test Questions and Answers Graded A+

 5 keer bekeken  0 keer verkocht
  • Vak
  • CT Registry
  • Instelling
  • CT Registry

CT Registry Review Program Post-Test Questions and Answers Graded A+ Bremsstrahlung radiation does NOT include which type of electron activity? 1. Collision between an incoming electron and the nucleus of the target atom 2. Collision between an incoming electron and an electron in an inner shell...

[Meer zien]

Voorbeeld 2 van de 7  pagina's

  • 19 september 2024
  • 7
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • CT Registry
  • CT Registry
avatar-seller
CT Registry Review Program Post-Test
Questions and Answers Graded A+

Bremsstrahlung radiation does NOT include which type of electron activity?
1. Collision between an incoming electron and the nucleus of the target atom
2. Collision between an incoming electron and an electron in an inner shell of the target
atom
3. Slowing down of an incoming electron due to the effect of passing close to the
positive charge of the nucleus of the target atom - answer2 only. Collision between an
incoming electron and an electron in an inner shell of the target atom describes
characteristic radiation.

Collimation is accomplished by: - answer Physically blocking x-rays

Which of the following statements is FALSE regarding occurrences after an x-ray
photon penetrates the detector aperture?
1. The photon can pass through the detector unmeasured
2. The photon is converted completely into an electron
3. The measured signal is enhanced by an amplifier - answer2 only

Which of the following utilizes convolution?
1. 3D SSD
2. Fourier Transform
3. Filtered back projection - answer3 only. Filtered back projection

In which technique are tissues other than the surface of a structure excluded by setting
a threshold value and eliminating pixels above or below that threshold?
a. volume rendering
b. multi-planar reconstruction
c. maximum intensity projection
d. 3D shaded surface display - answerD. 3D shaded surface display

Which of the following statements is TRUE?
1. The amplified electrical signal obtained from the detectors must be digitized
2. Digital CT images are numerical representations of cross-sectional anatomy
3. Digital signals may be formed by sampling analog signals at discrete time intervals -
answer1, 2 & 3

A single 2D picture element within the image plane - answerPixel

, The pencil thin section of the x-ray fan beam that strikes a single detector is called a: -
answerRay

Determines the intensity of the laser beam in a laser camera - answerPixel values in the
image data

Allows helical data to be converted into planar raw data - answerInterpolation

The most common type of film used for recording CT images - answerSingle emulsion

MDCT scanners capable of collecting 64 slices in a single rotation do NOT: -
answerUse filtered back projection as their method of image reconstruction.

What benefits does the dual focal spot provide compared to a single focal spot? -
answerThe number of projections is doubled.

CT numbers ______ would appear black if a window width of 400 and a window level of
-100 are used.
a. above +200
b. below -300
c. below -200
d. above +100 - answerB. below -300

Which of the following is FALSE about the spatial resolution of an image?
1. resolution is dependent on matrix size
2. resolution is dependent on reconstruction FOV
3. resolution is dependent on scanned FOV - answer3 only

An increase in _____ will result in hardening of an x-ray beam.
1. tissue density
2. tissue thickness
3. kVp - answer1, 2 & 3

Which of the following will result in an increased voxel size?
1. decreased reconstruction FOV
2. increased slice thickness
3. increased matrix - answer2. Increased slice thickness.

Which of the following does NOT occur when reconstruction FOV is decreased?
1. spatial resolution is increased
2. pixel size is increased
3. noise in the image increases - answer2 only

Which of the following occurs when slice thickness is reduced?
1. appearance of noise in the image increases
2. the number of photons used in making the slice decreases

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper julianah420. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €13,25. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 80630 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€13,25
  • (0)
  Kopen