Inspector 1 Questions and Answers The service specific item that contains a checklist of areas/systems to inspect is: The fire prevention/protection record The minimum temp that must be maintained in order to use a wet pipe sprinkler system is 40 F Previous Play Next Rewind 10...

[Meer zien]

Voorbeeld 2 van de 6  pagina's

  • 24 september 2024
  • 6
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • Fire Inspector
  • Fire Inspector
avatar-seller
Inspector 1 Questions and Answers

The service specific item that contains a checklist of areas/systems to inspect is: -
answer The fire prevention/protection record

The minimum temp that must be maintained in order to use a wet pipe sprinkler system
is - answer40 F

Class lll standpipe systems have a? - answercombination of a single 1 1/2 hose and a
single 2 1/2 connection

The extinguishing agent most effective on a fire involving animal or vegetable oils is: -
answerwet chemical

the type of alarm system most likely to result in a direct dispatch of fire personnel to a
fire scene is: - answera remote supervisory station alarm

The detector that signals the presence of smoke when a beam of light is refracted is: -
answerphotoelectric light-scattering

the kind of smoke detector that uses a pump to draw air samples into a high-humidity
chamber is a - answercloud chamber air sampling detector

use a portable fire extinguisher with a rating of 4-A, 20 B:C on: - answerordinary
combustibles, flammable liquids, and energized electrical equipment

you can tell the type of metals for which a class D portable fire extinguisher is approved
by: - answerlooking at the metals listed on the face plate

Door and windows allowed in a fire wall are referred to as - answerprotected openings

before the occupant load for a building can be calculated, you must know the: -
answersquare footage and use of the building

in determining the means of egress, an occupant load of less that 200 persons requires
a minimum of _______ exits - answer2

the clearance between a newly installed handrail and a wall cannot be less that -
answer2 1/4in

The means of egress must be illuminated at a minimum of ________ foot-candles -
answerone

, when more that one exit is needed in an unsprinklered room or building, exits should be
separated by at least one half the ________ distance of the room - answerdiagonal

in a cooking exhaust system, the filter will be found in the - answertype l hood

cooking equipment must be kept away from combustible material by a distance of at
least - answer18 in

the maximum number of storage cabinets allowable in a spray area is: - answerthree

structural sections of a spray area can be sealed with: - answerlatex-based caulk

two ways you may be able to determine weather a decorative material meets NFPA
requirements; - answer- performing a field flammability test
-reading the label

interior floor finishes are grouped into classes determined by the: - answercritical radiant
flux ratings

on a sprinkler system, the clapper valve is found in the: - answeralarm valve

the purpose of a dry pipe valve is to: - answerkeep water out of the sprinkler system
until a fire activates a sprinkler

three important things to check or validate during a visual inspection of a fire
extinguisher - answer-check the inspection tag
-ensure the pin and seal are in place
-look for signs of visible physical damage

when inspecting the distribution main in a sprinkler system, pay careful attention to all
components because the distribution main is the pipe that: - answerprovides the water
supply for the system

the person normally assigned to make the head count at an exit drill gathering area is
the: - answerevacuation monitor

The best way to test fire evacuation plans is to conduct - answerregular fire exit drills

water distribution systems are made up of a primary feeders(mains) secondary feeders,
and: - answerdistributors

to compute hydrant flow, you must know the coefficient of discharge ( based upon the
shape of the hydrant outlet), the diameter of the hydrant, and: - answerthe pressure
read at the hydrant orifice

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper julianah420. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €11,79. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 79276 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€11,79
  • (0)
  Kopen