Grenz - Answer--10-15 kVp -used for benign skin conditions contact - Answer--applicators in direct contact with treatment area -used for rectal (RT 50-kVp) and skin cancers superficial - Answer-- 50-150 kVp - SSD was typically 15-20 cm source to skin distance with cone in contact with lea...

[Meer zien]

Voorbeeld 2 van de 6  pagina's

  • 7 oktober 2024
  • 6
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • Radiation therapy
  • Radiation therapy
avatar-seller
Radiation Therapy II Chapter 9 Exam
Questions and Answers
Grenz - Answer--10-15 kVp
-used for benign skin conditions

contact - Answer--applicators in direct contact with treatment area
-used for rectal (RT 50-kVp) and skin cancers

superficial - Answer-- 50-150 kVp
- SSD was typically 15-20 cm source to skin distance with cone in contact with lead cut-
out or skin

orthovoltage - Answer-- 200-300 kVp
-most common SSD was 50 cm
-cones used to collimate beam

dmax - Answer--the depth of dmax is directly related to the energy of the beam
-for energies in the KV range, dmax occurs at the surface of the skin

What could cause the dose to increase below the surface? - Answer-secondary
ionization events caused by electrons that are set in motion

When did cobalt 60 first start being used? - Answer-1950s

cobalt 60 - Answer-- teletherapy unit no longer used in USA
-gamma ray source (radioactive) with average energy 1.25 MV
-capable of isocentric treatment

What offered skin sparing for the first time? - Answer-cobalt 60

Linear accelerators - Answer--came into widespread use in USA in 1970s
-dual photon energies ranging from 4-20 MV
-multiple electron energies ranging from 4 MeV to 22 MeV

What does cobalt 60 decay through? - Answer--beta decay to Nickel
- It decays continuously and has a half life of 5.25 years
-because of continuous decay the amount of time to deliver a specified dose increases
over time

What is the average energy of cobalt 60? - Answer-1.25 MV

What was the SAD of a teletherapy cobalt 60 unit? - Answer-80 cm

, Source to skin distance (SSD) - Answer-distance from the source (target) of the
machine to the surface of the patient

source to axis distance (SAD) - Answer-distance from the source (target) of the
machine to the isocenter

isocenter - Answer--the intersection of the gantry, collimator and couch rotations of axis
-a point in free space that is independent of patient position

what is the distance from the source to the isocenter? (SAD) - Answer--100 cm for a
linear accelerator
-80 cm for cobalt 60 units

Where are the collimator and gantry axis of rotation in reference to each other? -
Answer--perpendicular to each other
-if their axes do not intersect then parallel opposed beams will not be truly opposed

Major components of linear accelerator treatment unit - Answer--modulator cabinet
-drive stand
-gantry
-patient support assembly
-control console

Major components of a modulator cabinet - Answer--fan control
-primary power distribution
-auxiliary power distribution

Fan control - Answer-allows for cooling of power distribution systems

primary power distribution - Answer-major power route for accelerator

auxiliary power distribution - Answer--emergency off buttons
-timers to record use of klystron, gun filament for purposes of preventative maintenance
and warranty

Major components of the drive stand - Answer--klystron or magnetron (one or the other)
-waveguide
-circulator
-water cooling system

Magnetron - Answer-a direct source of microwaves; used for low energy photon beams
<6MV

Klystron - Answer-is an amplifier of microwaves; used for 10 MV and above

Microwaves in linacs - Answer--needed in order to accelerate the electrons

Dit zijn jouw voordelen als je samenvattingen koopt bij Stuvia:

Bewezen kwaliteit door reviews

Bewezen kwaliteit door reviews

Studenten hebben al meer dan 850.000 samenvattingen beoordeeld. Zo weet jij zeker dat je de beste keuze maakt!

In een paar klikken geregeld

In een paar klikken geregeld

Geen gedoe — betaal gewoon eenmalig met iDeal, creditcard of je Stuvia-tegoed en je bent klaar. Geen abonnement nodig.

Direct to-the-point

Direct to-the-point

Studenten maken samenvattingen voor studenten. Dat betekent: actuele inhoud waar jij écht wat aan hebt. Geen overbodige details!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper lectknancy. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €11,92. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 71250 samenvattingen verkocht

Opgericht in 2010, al 15 jaar dé plek om samenvattingen te kopen

Begin nu gratis

Laatst bekeken door jou


€11,92
  • (0)
In winkelwagen
Toegevoegd