1.- Nonshielded conductors over 700 V shall be __________ - ️️GROUNDED 2.- What is the minimum distance that is allowed between switchgear and an outdoor oil storage tank? - ️️10 Feet. 3.- What is the minimum vertical separation on a Pole between the supply cable and the lowest communicat...

[Meer zien]

Voorbeeld 3 van de 16  pagina's

  • 8 oktober 2024
  • 16
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • Electrical Theory Path
  • Electrical Theory Path
avatar-seller
Electrical Theory Path to Excellence 280
Targeted Questions for Top Grades
1.- Nonshielded conductors over 700 V shall be __________ - ✔ ✔ GROUNDED

2.- What is the minimum distance that is allowed between switchgear and an outdoor oil storage tank? -
✔ ✔ 10 Feet.

3.- What is the minimum vertical separation on a Pole between the supply cable and the lowest
communication attachment. - ✔ ✔ 16 Inches

4.- The vertical clearance for insulated communication conductors above or crossing Railroads tracks
shall be __________feet. - ✔ ✔ 23.5 Feet

5.- Minimum clearance for non-insulated communications conductors over pedestrian walkways shall be
__________feet. - ✔ ✔ 12 Feet

6.- Minimum clearance of open supply conductors over 750 V to 22 KV crossing over bridges shall be
___________feet. - ✔ ✔ 5.5 Feet.

7.- The minimum vertical clearance between ordinary supply conductors over 8.7 KV and
communications conductors shall be _______inches. - ✔ ✔ 40 + 0.4 per KV over 8.7 KV

8.- Backfill within 6" of conduit should be free of solid material greater than __________maximum
dimension. - ✔ ✔ 4 Inches.

9.- In Underground structures, horizontal runs of supply cables shall be supported at least ______above
the floor. - ✔ ✔ 3 Inches.

10.- What is the minimum burial depth for a 22 KV conductor? - ✔ ✔ 30 Inches

11.- What is the minimum flush burial depth of a 500 Volt conductor? - ✔ ✔ 24 Inches.

12.- Pad mounted equipment shall not be located less than ______feet from hydrants - ✔ ✔ 4 Feet.

13.- Bonding shall be provided between all above ground metallic power and communication apparatus
that are separated _______ or less. - ✔ ✔ 6 Feet.

14.- According to the NESC, fall protection is required for over ________ feet elevation. - ✔ ✔ 10
Feet.

15.- A buried_________ Shall be used to bond across a gate, unless a non-conducting fence section is
used. - ✔ ✔ Bonding Jumper.

,16.- Where guarding is required, grounding conductor guards should extend for not less than
______feet above the ground or platform from which the grounding conductors are accessible to the
public. - ✔ ✔ 8 Feet.

17.- Strips of metal not less than_______ in total length constitute an acceptably made electrode. - ✔
✔ 10 Feet.

18.- In areas with high soil sensitivity or shallow bedrock, buried strips of metal not less than _______in
total length, constitute an acceptably made electrode. - ✔ ✔ 10 Feet.

19.- Pole butt plates shall not be less than ______thick. - ✔ ✔ 1/4 Inch.

20.- Copper wire wrap shall have a continuous bare length below the ground level not less than
_______Feet. - ✔ ✔ 12 Feet.

21.- Copper wire wrap shall not be smallest than _______. - ✔ ✔ 6 AWG.

22.- Minimum overhang for insulated communication conductors over Roads and Parking Lots Shall be
______Feet - ✔ ✔ 15.5 Feet.

23.- The suppler or conductor that installs house fire warning is required to provide the building owner
with all the following materials except: - ✔ ✔ Drawing that shows the interconnection of Tandem
connected detectors

24.- On a Beam Ceiling where the Beams are less than 12" in depth and spacing is less than 96", where
should the smoke detectors be mounted. - ✔ ✔ Bottom of the Beam

25.- The maximum Air velocity for a smoke detector is __________ - ✔ ✔ 300 Fpm.

26.- Visible notification appliances located in corridors shall be space no more than ______feet apart -
✔ ✔ 100 Feet.

27.- Given: A smoke detection system is been installed to automatically close a double door way in
response to smoke blowing in either direction. The ceiling is smooth, where must be the smoke detector
be installed? - ✔ ✔ On the center line of the doorway.

28.- On a voice alarm System, what is the minimum number of cycles it has to report an evacuation
procedure? - ✔ ✔ 2

29.- A single store dwelling unit has two bedrooms that are not located near to one another. What is the
minimum required number of smoke alarms required? - ✔ ✔ 4

30.- HEAT DETECTORS used within a single family unit must be listed or approved for not less than
_______spacing - ✔ ✔ 50 Feet.

31.- What is a privately owned and monitored alarm system classified as? - ✔ ✔ Proprietary System.

, 32.- What is a Decibel? - ✔ ✔ 1/10 of a Bell.

33.- Notification appliances of a local protective signaling system must include on their
nameplate_______. - ✔ ✔ Electrical requirements & Rated audible or visible performance

34.- A fire alarm system is required or a visible notification device when the ambient sound is Greater
than ? - ✔ ✔ 105 dBa.

35.- What is the maximum blink rate on a strobe light on a notification appliance per second? - ✔ ✔
2.

36.- What is the maximum interval that a fire alarm signal is allowed at the console? - ✔ ✔ 15 sec.

37.- What is the detector that is mounted on the ceiling or wall that reacts to converted Thermal
reaction? - ✔ ✔ HEAT DETECTOR.

38.- Components that are non fire alarm and connected commonly to fire alarm, components are
considered what type of system? - ✔ ✔ Combination System.

39.- Electrical Power is measured in _____________ - ✔ ✔ WATTS.

40.- You have a frequency that has been amplified to four frequencies. This change is called: - ✔ ✔
FREQUENCY MULTIPLEXING.

41.- What type of a Network is not considered Multipoint. - ✔ ✔ Point to Point.

42.- When a company ties together different devices such as COMPUTERS & PRINTERS, What is the
result? - ✔ ✔ A Network.

43.- Which part of a Power supply converts electrical current from AC to DC? - ✔ ✔ RECTIFER.

44.- The standard Impedance of a video Coaxial cable is _____ Ohms - ✔ ✔ 75 Ohms.

45.- Telecom Wire is grounded on each end. What is the electrical Path called? - ✔ ✔ Ground Loop

46.- A voltmeter will test all of the following, except: - ✔ ✔ POWER.

47.- What is the disadvantages of Fiber Optics over Copper? - ✔ ✔ COST.

48.- What is the measurement of the amount of signal for Fiber Optics? - ✔ ✔ BANDWIDTH

49.- Switch S1 is in the ON position but light L does not come on. Voltages across S1 is measured to be
120 Volts, Voltage across L1 is measured to be 0 Volts. The light does not come on because: - ✔ ✔
Lamp is good, but the switch does not make contact.

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper jackline98. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €8,58. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 83750 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€8,58
  • (0)
  Kopen