What table sizes bonding jumpers for for AC systems? - ANSWER250.102(C)(1) The NEC defines continuous load to be a load where max current on the circuit continues for at least how many hours? - ANSWERThree To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how ...

[Meer zien]

Voorbeeld 2 van de 8  pagina's

  • 24 oktober 2024
  • 8
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • Journeyman electrician
  • Journeyman electrician
avatar-seller
Journeyman electrician exam prep
ACCURATE 100%
What table sizes bonding jumpers for for AC systems? - ANSWER250.102(C)(1)



The NEC defines continuous load to be a load where max current on the circuit continues for at least
how many hours? - ANSWERThree



To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many current
carrying conductors in a raceway? - ANSWERGreater than three



Where in the NEC codebook would you find EMT sizes for a given size and number of conductors? -
ANSWERAnnex C, Table C.1



Section 210.20(A) states that the over current protection for branch circuits including continuous
loads must be greater than 100% of the noncontinuous plus ____ of the continuous load. -
ANSWER125%



Liquidtight Flexible Metal Conduit shall be fastened within of each box or other conduit termination -
ANSWERTwelve inches



314.28(A)(1) states that straight pulls in pull boxes with conductors size 4 AWG or larger, box length
should be greater than or equal to times the trade diameter of the largest conduit entering box. -
ANSWEREight



Chapter 9 note 4 states conduit nipples less than 24 inches can fill to a max of their cross sectional
area - ANSWER60 percent



Table 348.22 gives the max number of insulated conductors in size _______ FMC? - ANSWER3/8
(trade size)



Guest rooms of hotels, motels, & sleeping rooms in dorms need a MIN or _____ general purpose
receptacles installed that are readily accessible? - ANSWERTwo

, When branch-circuit conductors are contained inside a ballast compartment and they are within 3
inches of the ballast, the conductors shall have a temperature rating of at LEAST _____.



a) 105 degrees C

b) 90 degrees C

c) 75 degrees C

d) 60 degrees C - ANSWERB: 90 degrees C

Ref: 410.68



Class _____ locations are those that are hazardous because of the presence of easily ignitible fibers
or materials producing combustible flyings.



a) I

b) II

c) III

d) IV - ANSWERC: III

Ref: 500.5(D)



Class _____ locations are those in which flammable gases, flammable liquid produced vapors, or
combustible liquid produced vapors are present that are explodable. - ANSWERClass 1



Class ____ locations are those that are hazardous because of combustible dust - ANSWERClass II



Conductors with _______ Insulation have a greater ampacity when used in a dry location compared
to when used in a wet location - ANSWERTHHW



When calculating total load for buildings and finding minimum branch circuit load, what must be
factored into the volt amps for an exterior electric sign? - ANSWERDemand load (1.25)



Table C.11 and C.11(A) show conductor numbers for size for schedule 40 PVC, what is the difference
in charts? - ANSWERCompact vs stranded conductors

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper ClassRep2. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €13,12. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 75759 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€13,12
  • (0)
  Kopen