100% tevredenheidsgarantie Direct beschikbaar na betaling Zowel online als in PDF Je zit nergens aan vast
logo-home
Computed Tomography for Technologists 2nd Edition Exam Review Questions and Answers 100% Pass €13,12   In winkelwagen

Tentamen (uitwerkingen)

Computed Tomography for Technologists 2nd Edition Exam Review Questions and Answers 100% Pass

 1 keer bekeken  0 keer verkocht
  • Vak
  • Prep Tests
  • Instelling
  • Prep Tests

Computed Tomography for Technologists 2nd Edition Exam Review Questions and Answers 100% Pass Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT examination? A. Topogram B. Scout C. Scanogram D. Spiral - ANSWER-D. Spiral The ability of a system to differen...

[Meer zien]

Voorbeeld 4 van de 62  pagina's

  • 10 november 2024
  • 62
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • Prep Tests
  • Prep Tests
avatar-seller
Copyright © KAYLIN 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED




Computed Tomography for Technologists

2nd Edition Exam Review Questions and

Answers 100% Pass


Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT examination?


A. Topogram


B. Scout


C. Scanogram


D. Spiral - ANSWER✔✔-D. Spiral


The ability of a system to differentiate, on the image, objects with similar densities is known as:


A. High contrast resolution


B. Low contrast resolution


C. Spatial resolution


D. Temporal resolution - ANSWER✔✔-B. Low contrast resolution


Each two dimensional square of data that make up the CT image is called a:


A. Pixel


B. Voxel


C. Matrix

Copyright ©Stuvia International BV 2010-2024 Page 1/62

, Copyright © KAYLIN 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED


D. Fragment - ANSWER✔✔-A. Pixel


How many pixels are contained in a 1,024 matrix image? A. 1,024


B. 2,048


C. 262,144


D. 1,048,576 - ANSWER✔✔-D. 1,048,576


Beam attenuation can be defined as:


A. The phenomenon by which artifacts result when lower energy photons are preferentially absorbed,

leaving only higher-intensity photons to strike the detector array.


B. Xray energy that is produced from bombarding a substance with fast moving electrons.


C. The ability of the detector to capture transmitted photons and change them to electronic signals.


D. The phenomenon by which an xray beam passing through a structure is decreased in intensity or

amount because of absorption and interaction with matter. - ANSWER✔✔-D. The phenomenon by which

an xray beam passing through a structure is decreased in intensity or amount because of absorption and

interaction with matter.


Which of the following is a low attenuation structure:


A. Iodine filled aorta


B. Rib


C. Trachea


D. Calcified arteries - ANSWER✔✔-C. Trachea



Copyright ©Stuvia International BV 2010-2024 Page 2/62

, Copyright © KAYLIN 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED


An object is slightly less dense than water. What is the expected hounsfield measurement?


A. -940


B. -10


C. 50


D. 850 - ANSWER✔✔-B. -10


Why does the administration of iodinated contrast media result in an enhanced image?


A. Iodinated contrast material increases the ability of the enhanced structure to attenuate the xray

beam.


B. Iodinated contrast material decreases the average photon energy of the xray beam; therefore more

photons are absorbed by the patient.


C. The administration of contrast material results in a smaller pixel, thereby increasing spatial resolution,

which results in an enhanced image.


D. - ANSWER✔✔-A. Iodinated contrast material increases the ability of the enhanced structure to

attenuate the xray beam.


The xray beam sources for CT produce xray energy that is polychromatic. This means:


A. When viewed by the naked eye, the beam exhibits many different colors.


B. It produce, as a byproduct, a substance known as polychlorinated biphenyl.


C. Photons contained in the beam are all of the same wavelength.


D. The beam comprises photons with varying energies. - ANSWER✔✔-D. The beam comprises photons

with varying energies.

Copyright ©Stuvia International BV 2010-2024 Page 3/62

, Copyright © KAYLIN 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED


An object that appears on the image but is not present in the object scanned is called a/n:


A. Artifact


B. Anomaly


C. Shadow


D. Ghost - ANSWER✔✔-A. Artifact


Which is an advantage of filtering the xray beam?


A. Filtering reduces the anode heat load


B. A filtered beam produces images with substantially less quantum mottle


C. Filtering the beam prevents energy from being converted to heat, therefore 100% of the energy is

converted to xrays.


D. Filtering reduces the radiation dose to the patient. - ANSWER✔✔-D. Filtering reduces the radiation

dose to the patient


Scan thickness is primarily important for the part it plays in:


A. Noise reduction


B. The contrast scale


C. Detector aperture opening


D. Volume averaging - ANSWER✔✔-D. Volume averaging




Copyright ©Stuvia International BV 2010-2024 Page 4/62

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper OliviaWest. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €13,12. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 75323 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€13,12
  • (0)
  Kopen