Regarding scope and depth of real estate inspections, an inspector must first adhere to all rules: -
Correct answer.(b) Chapter 1102 of the Texas Occupations Code
During inspection, mechanical and electrical systems and appliances are: - Correct answer.(b) Only
operated in normal modes and operating ranges
The inspector is required to render a written report in a format promulgated by the state: - Correct
answer.(b) Unless a different format is required by an agency of the federal government
(c) Unless a different format is required by a client who buys or sells property in the due course of the
client's business
Inspectors are usually required to: - Correct answer.(d) Inspect for the presence of arc fault protected
circuits
The inspection of foundation, grading, and drainage does not require observations regarding: - Correct
answer.(d) Underground drainage systems
Roof inspections require: - Correct answer.(a) Walking on the roof
(b) Identification of the roof covering material
Inspectors should report the approximate depth of attic insulation: - Correct answer.(c) Whenever the
insulation is visible
Inspectors are not required to report: - Correct answer.(d) The absence of storm doors
, Inspectors are required to inspect: - Correct answer.(a) Operation of doors
During the inspection of a fireplace, inspectors look for: - Correct answer.(b) Presence and adequacy of
non-combustible hearth extension
(c) Presence and condition of crown and spark arrestor
During electrical inspections: - Correct answer.(a) Integrity of service entrance cables and insulation are
observed
(b) The presence or absence of a grounding system is observed
(c) Inspection is made for the compatibility of overcurrent protectors with conductor sizes
Electrical receptacles are not inspected for: - Correct answer.(d) Voltage
GFCI protection is not required for receptacles: - Correct answer.(d) Within 5 feet of furnace blower
locations
Furnace question: Inspectors are not required to: - Correct answer.(d) Fully evaluate the integrity of the
heat exchanger in gas fired furnaces
AC question: Inspectors are required to: - Correct answer.(a) Observe for the presence and condition of
insulation on air conditioner suction pipes and primary condensate drain lines
(c) Inspect air conditioner condensing units for the condition of fins
AC question: Inspectors are not required to: - Correct answer.(a) Measure the pressure of air conditioner
system refrigerant
(b) Determine the presence of refrigerant leaks
(c) Report adequacy of air conditioner capacity as related to the homes square footage
During plumbing system inspection, observation must be made regarding: - Correct answer.(a) Type and
condition of accessible and visible supply pipes
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper learnsphere. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €8,96. Je zit daarna nergens aan vast.