Journeyman Electrical Closed Book Exam #2 Missed Questions With Solutions 100% Solved
Journeyman Electrical Closed Book Exam #2 
Missed Questions With Solutions 100% 
Solved 
What is the function of a neon glow tester? Determines if circuit is alive, determines 
polarity, and determines if circuit is AC or DC. 
The connection of a ground clamp to a grounding electrode shall be ____. Accessible. 
Mandatory rules of the Code are identified by the use of the word ____. Shall. 
If a test lamp lights when places in series with a conductor and suitable source of DC, it is a good 
i...
- Tentamen (uitwerkingen)
- • 3 pagina's •
Journeyman Electrical Closed Book Exam #2 
Missed Questions With Solutions 100% 
Solved 
What is the function of a neon glow tester? Determines if circuit is alive, determines 
polarity, and determines if circuit is AC or DC. 
The connection of a ground clamp to a grounding electrode shall be ____. Accessible. 
Mandatory rules of the Code are identified by the use of the word ____. Shall. 
If a test lamp lights when places in series with a conductor and suitable source of DC, it is a good 
i...
Journeyman Electrician #5 Questions With Solutions 100% Solved
Journeyman Electrician #5 Questions With 
Solutions 100% Solved 
Which of the following grounding electrodes is NOT permitted to be used as an effective 
ground-fault current path? 
a) the metal frame of a building or structure 
b) a metal underground water pipe in direct contact with the earth for 10 feet or more 
c) an electrode encased by at least 2 inches of concrete 
d) the earth D: the earth 
Ref: 250.4(A)(5); 250.54 
Primary overcurrent devices, impedance limiting means, or other inhere...
- Tentamen (uitwerkingen)
- • 14 pagina's •
Journeyman Electrician #5 Questions With 
Solutions 100% Solved 
Which of the following grounding electrodes is NOT permitted to be used as an effective 
ground-fault current path? 
a) the metal frame of a building or structure 
b) a metal underground water pipe in direct contact with the earth for 10 feet or more 
c) an electrode encased by at least 2 inches of concrete 
d) the earth D: the earth 
Ref: 250.4(A)(5); 250.54 
Primary overcurrent devices, impedance limiting means, or other inhere...
Journeyman Exam #5 With Solutions 100% Solved
Journeyman Exam #5 With Solutions 100% 
Solved 
d. Prevent he connector from loosening under vibration Locknuts are sometimes used in 
making electrical connections on studs. In this case the purpose of this locknuts is to ______ 
a. Be able to connect several wires to one stud 
b. Make it difficult to tamper with the connection 
c. Make a tighter connection 
d. Prevent he connector from loosening under vibration 
c. Use a hacksaw and ream To cut rigid conduit you should ________ 
a. Use a 3-w...
- Tentamen (uitwerkingen)
- • 19 pagina's •
Journeyman Exam #5 With Solutions 100% 
Solved 
d. Prevent he connector from loosening under vibration Locknuts are sometimes used in 
making electrical connections on studs. In this case the purpose of this locknuts is to ______ 
a. Be able to connect several wires to one stud 
b. Make it difficult to tamper with the connection 
c. Make a tighter connection 
d. Prevent he connector from loosening under vibration 
c. Use a hacksaw and ream To cut rigid conduit you should ________ 
a. Use a 3-w...
Journeyman exam #11 With Solutions 100% Solved
Journeyman exam #11 With Solutions 100% 
Solved 
A ———- circuit operating at 600v , nominal , or less , between phases that connects two power 
sources or power supply points , such as the secondaries of two transformers Secondary 
tie 
Entrances to rooms and other guarded locations containing exposed live parts shall be marked 
with ———- warning signs forbidding unqualified person to enter Conspicuous 
Overhead spans of open conductors and open multiconductor cables not over 600...
- Tentamen (uitwerkingen)
- • 3 pagina's •
Journeyman exam #11 With Solutions 100% 
Solved 
A ———- circuit operating at 600v , nominal , or less , between phases that connects two power 
sources or power supply points , such as the secondaries of two transformers Secondary 
tie 
Entrances to rooms and other guarded locations containing exposed live parts shall be marked 
with ———- warning signs forbidding unqualified person to enter Conspicuous 
Overhead spans of open conductors and open multiconductor cables not over 600...
Journeyman Exam 1 & 2 With Solutions 100% Solved
Journeyman Exam 1 & 2 With Solutions 
100% Solved 
A switch intended for use in general distribution and branch circuits. It is rated in amperes, and it 
is capable of interrupting its rated current at its rated voltage, is a _______ switch. 
a. bypass isolation 
b. general use 
c. isolating 
d. transfer Ans. b 
The permanent joining of metallic parts to form an electrically conductive path that will ensure 
electrical continuity and the capacity to conduct safely any current likely to be im...
- Tentamen (uitwerkingen)
- • 38 pagina's •
Journeyman Exam 1 & 2 With Solutions 
100% Solved 
A switch intended for use in general distribution and branch circuits. It is rated in amperes, and it 
is capable of interrupting its rated current at its rated voltage, is a _______ switch. 
a. bypass isolation 
b. general use 
c. isolating 
d. transfer Ans. b 
The permanent joining of metallic parts to form an electrically conductive path that will ensure 
electrical continuity and the capacity to conduct safely any current likely to be im...
Journeyman Final Exam With Solutions 100% Solved
Journeyman Final Exam With Solutions 
100% Solved 
A 1-inch conduit contains three 3-wire circuits. All conductors are #10 TW. Each circuit consist 
of two 
phase conductors, one grounded conductor, and one equipment grounding conductor. The 
maximum 
ampacity of each phase conductor is__________ amps. 
a. 24 
b. 28 
c. 30 
d. 35 a
- Tentamen (uitwerkingen)
- • 27 pagina's •
Journeyman Final Exam With Solutions 
100% Solved 
A 1-inch conduit contains three 3-wire circuits. All conductors are #10 TW. Each circuit consist 
of two 
phase conductors, one grounded conductor, and one equipment grounding conductor. The 
maximum 
ampacity of each phase conductor is__________ amps. 
a. 24 
b. 28 
c. 30 
d. 35 a
Michigan Journeyman test With Solutions 100% Solved
Michigan Journeyman test With Solutions 
100% Solved 
A general purpose receptacle shall not be installed on the_________ Offense directly 
south of the pool 
A junction box for a 124 wet niche fixture shall be at least_______Inches above the ground 
 4 
A GFCI protected_______ receptacle for the pump motor May be installed on the south side of 
the dwelling unit dedicated grounding type Dedicated receptacle 
A metal fence installed within________Feet of a pool Shall be bonded 5 
The feed to...
- Tentamen (uitwerkingen)
- • 12 pagina's •
Michigan Journeyman test With Solutions 
100% Solved 
A general purpose receptacle shall not be installed on the_________ Offense directly 
south of the pool 
A junction box for a 124 wet niche fixture shall be at least_______Inches above the ground 
 4 
A GFCI protected_______ receptacle for the pump motor May be installed on the south side of 
the dwelling unit dedicated grounding type Dedicated receptacle 
A metal fence installed within________Feet of a pool Shall be bonded 5 
The feed to...
NEC Journeyman Test Prep With Solutions 100% Solved
NEC Journeyman Test Prep With Solutions 
100% Solved 
Surge arrestors are grounded at the arrestor grounding terminal and the arrestor grounding 
conductor is ran in a metal enclosure. The grounding conductor must be bonded on which end of 
the enclosure? Both ends of enclosure. 
280.25 
Single throw knife switches shall be mounted so gravity will not do what to the circuit? 
 Close. 
404.6 (A) 
Where direct buried conductors or cables emerge from the ground, they shall be protected by 
enc...
- Tentamen (uitwerkingen)
- • 5 pagina's •
NEC Journeyman Test Prep With Solutions 
100% Solved 
Surge arrestors are grounded at the arrestor grounding terminal and the arrestor grounding 
conductor is ran in a metal enclosure. The grounding conductor must be bonded on which end of 
the enclosure? Both ends of enclosure. 
280.25 
Single throw knife switches shall be mounted so gravity will not do what to the circuit? 
 Close. 
404.6 (A) 
Where direct buried conductors or cables emerge from the ground, they shall be protected by 
enc...
PSI Journeyman Online Practice Test With Solutions 100% Solved
PSI Journeyman Online Practice Test With 
Solutions 100% Solved 
Where the negative polarity of a dc system does not serve as the connection point for the 
grounded conductor, which color finish can be used to identify the negative ungrounded 
conductor? black 
Where a feeder supplies continuous loads or any combination of continuous and noncontinuous 
loads, the minimum feeder conductor size shall have an allowable ampacity not less than the 
noncontinuous load plus what percentage of the ...
- Tentamen (uitwerkingen)
- • 18 pagina's •
PSI Journeyman Online Practice Test With 
Solutions 100% Solved 
Where the negative polarity of a dc system does not serve as the connection point for the 
grounded conductor, which color finish can be used to identify the negative ungrounded 
conductor? black 
Where a feeder supplies continuous loads or any combination of continuous and noncontinuous 
loads, the minimum feeder conductor size shall have an allowable ampacity not less than the 
noncontinuous load plus what percentage of the ...
Journeyman Electrician Practice Test With Solutions 100% Solved
Journeyman Electrician Practice Test With 
Solutions 100% Solved 
To find the full-load current rating of the single-phase transformer apply the single-phase current 
formula as shown:I = (150 kVA x 1000) / 240 volts = 15,000/240 = 625 amperes 
Which one of the following listed circuit breakers is NOT a standard ampere rating? 75 
amperes 
the standard ampere ratings for fuses and circuit breakers. A circuit breaker with an ampere 
rating of 75 amperes is not a standard ampere rating. 
The M...
- Tentamen (uitwerkingen)
- • 21 pagina's •
Journeyman Electrician Practice Test With 
Solutions 100% Solved 
To find the full-load current rating of the single-phase transformer apply the single-phase current 
formula as shown:I = (150 kVA x 1000) / 240 volts = 15,000/240 = 625 amperes 
Which one of the following listed circuit breakers is NOT a standard ampere rating? 75 
amperes 
the standard ampere ratings for fuses and circuit breakers. A circuit breaker with an ampere 
rating of 75 amperes is not a standard ampere rating. 